1、Draft Storage/Stationary Batteries Standards List Courtesy of UL Standards Scope Summary General Purpose Comments Safety Performance Other UL 1973 Batteries for Use in Light Electric Rail (LER) and Stationary Applications Safety standard for stationary batteries for energy storage applications, Non

2、chemistry specific and includes electrochemical capacitor systems or hybrid electrochemical capacitor and battery systems. Includes requirements for unique technologies such as flow batteries and sodium beta (i.e. sodium sulfur and sodium nickel chloride) X Includes construction requirements, tests

3、and production tests. Also includes requirements for cells used in these systems such as lithium ion, nickel, lead acid and includes sodium beta and flow battery requirements UL Subject 9540, Safety for Energy Storage Systems and Equipment Under Development These requirements cover energy storage sy

4、stems that are intended to store energy from power or other sources and provide electrical or other types of energy to loads or power conversion equipment. The energy storage systems may include equipment for charging, discharging, control, protection, communication, controlling the system environme

5、nt, fuel or other fluid movement and containment, etc. The system may contain other ancillary equipment related to the functioning of the energy storage system. These are intended for use in utility-interactive applications in compliance with IEEE 1547 and IEEE 1547.1 or other applications intended

6、to provide grid support functionality. X Under Development These systems may be standalone to provide energy for local loads, or in parallel with an electric power system, electric utility grid or applications that perform multiple operational modes. EN 50272-2 Safety Requirements for Secondary batt

7、eries and battery installations: Part 2 stationary 1500 Vdc limit, protection against electricity, gas emission and electrolyte Limited to lead acid and nickel technologies X Applications for telecom, PV, UPS, emergency lighting, power station, stationary engine starting 名师资料总结 - - -精品资料欢迎下载 - - - -

8、 - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 1 页,共 11 页 - - - - - - - - - batteries EN5510-2-3 This standard gives guidance on writing the technical specificationfor the procurement of stationary batteries and chargers for use in electricity generating stations (power stations). X This Guide

9、does not determine the type of specification(e.g. detailed, performance, functional) or the extent of supply for any given contract which is normally decided on the basis of the purchaser sproject strategy. IEC 62485-2 Safety requirements for secondary batteries and battery installations Part 2: Sta

10、tionary batteries Appears identical to IEC 50272-2 This part of the IEC 62485 applies to stationary secondary batteries and battery installations with a maximum voltage of DC 1 500 V (nominal) and describes the principal measures for protections against hazards generated from: electricity, gas emiss

11、ion, electrolyte. This International Standard provides requirements on safety aspects associated with the erection, use, inspection, maintenance and disposal. X Appears to be same as IEC 50272-2 IEC 60896-11 Stationary lead-acid batteries Part 11: Vented types - General requirements and methods of t

12、ests This part of IEC 60896 is applicable to lead-acid cells and batteries which are designed for service in fixed locations and which are permanently connected to the load and to the dc power supply. This part 11 of the standard is applicable to vented types only. The object of this standard is to

13、specify general requirements and the main characteristics, together with corresponding test methods associated with all types and construction modes of lead-acid stationary batteries, excluding valve-regulated types. X X IEC 60896-21 Stationary lead-acid batteries Part 21: Valve regulated types Meth

14、ods of test Applies to all stationary lead-acid cells and mono-bloc batteries of the valve regulated type for float charge applications, (i.e. permanently connected to a load and to a dc power supply), in a static location and incorporated X X This part of IEC 60896 does not apply to lead-acid cells

15、 and mono-bloc batteries used for vehicle engine starting applications (IEC 60095 series), solar 名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 2 页,共 11 页 - - - - - - - - - into stationary equipment or installed in battery rooms for use in telecom, uninterruptible po

16、wer supply (UPS), utility switching, emergency power or similar Applications. The objective is to specify the methods of test for all types and construction of valve regulated stationary lead acid cells and mono-bloc batteries used in standby power applications. photovoltaic energy systems (IEC 6142

17、7), or general purpose applications (IEC 61056 series). IEC 60896-22 Stationary lead-acid batteries Part 22: Valve regulated types Requirements Applies to all stationary lead-acid cells and mono-bloc batteries of the valve regulated type for float charge applications, (i.e. permanently connected to

18、a load and to a dc power supply), in a static location and incorporated into stationary equipment or installed in battery rooms for use in telecom, uninterruptible power supply (UPS), utility switching, emergency power or similar applications. The objective of this part of IEC 60896 is to assist the

19、 specifier in the understanding of the purpose of each test contained within IEC 60896-21 and provide guidance on a suitable requirement that will result in the battery meeting the needs of a particular industry application and operational condition. X X This standard is used in conjunction with the

20、 common test methods described in IEC 60896-21 and is associated with all types and construction of valve regulated stationary lead-acid cells and mono-blocs used in standby power applications. This part of IEC 60896 does not apply to lead-acid cells and batteries used for vehicle engine starting ap

21、plications (IEC 60095 series), solar photovoltaic applications (IEC 61427), or general purpose applications (IEC 61056 series). IEC 61427-1 Secondary cells and batteries for photovoltaic energy systems (PVES) - General requirements and methods of test This International Standard gives general inform

22、ation relating to the requirements of the secondary batteries used in photovoltaic energy systems (PVES) and to the typical methods of test used for the verification of battery performance. This International Standard does not include specific information relating to battery sizing, method of charge

23、 or PVES design. NOTE: This standard is applicable to lead-acid and nickel-cadmium cells and batteries. It is intended to amend this standard to include other electrochemical systems when X 名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 3 页,共 11 页 - - - - - - - - - t

24、hey become available. IEC 60622 Secondary cells and batteries containing alkaline or other non-acid electrolytes Sealed nickel-cadmium prismatic rechargeable single cells This International standard specifies marking, tests and requirements for sealed nickel cadmium prismatic secondary single cells.

25、 X X IEC 60623 Secondary cells and batteries containing alkaline or other non-acid electrolytes Vented nickel-cadmium prismatic rechargeable single cells This International Standard specifies marking, designation, dimensions, tests and requirements for vented nickel-cadmium prismatic secondary singl

26、e cells. X X IEC 62259 Secondary cells and batteries containing alkaline or other non-acid electrolytes Nickel-cadmium prismatic secondary single cells with partial gas recombination This International Standard specifies marking, designation, dimensions, tests and requirements for vented nickel-cadm

27、ium prismatic secondary single cells where special provisions have been made in order to have partial or, under very specific conditions, full gas recombination. X X IEC CD 62619 Secondary cells and batteries containing alkaline or other non-acid electrolytes. - Safety requirements for secondary lit

28、hium cells and batteries, for use in industrial applications Under Development Covers cells and batteries for stationary applications and motive (other than on-road vehicle) X Under Development moving toward CDV stage. Includes safety requirements for lithium ion cells for stationary and off road mo

29、tive applications and some battery requirements (evaluation of battery and BMS combination) The standard is not a system standard as it 名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 4 页,共 11 页 - - - - - - - - - only covers battery and BMS interaction. IEC CDV 62620

30、Secondary cells and batteries containing alkaline or other non-acid electrolytes -Secondary cells and batteries containing alkaline or other non-acid electrolytes Secondary lithium cells and batteries for use in industrial applications Under Development This International Standard specifies, marking

31、, designation, dimensions, tests and requirements for large format lithium-ion secondary single cells and batteries used in Industrial Applications including Stationary applications.” X Under Development Next stage is DIS stage. Generic performance requirements for lithium ion cells and batteries fo

32、r stationary and off road motive applications. Tests based upon cell and battery specifications. IEC 62896 Stationary Energy Storage Systems with Lithium Batteries Safety Requirements Under Development This part of the standard specifies general safety requirements for stationary energy storages wit

33、h lithium batteries. The purpose of the requirements of this standard is to ensure that HAZARDS to the operator /user and the surrounding area are reduced to a tolerable level. Requirements for protection against particular types of HAZARDS: a) electric shock or burn b) mechanical hazards c) spread

34、of fire from the equipment d) excessive temperature e) effects of fluids and fluid pressure f) liberated gases, explosion g) chemical hazard e.g. electrolyte X Under Development This is a new work proposal. It covers small battery systems for residential or similar use that can be connected to a mai

35、ns source of supply IEEE 1184 IEEE Guide for Batteries for Uninterruptible Power Supply Systems This guide discusses various battery systems so that the user can make informed decisions on selection, installation design, installation, maintenance, and testing of stationary standby batteries used in

36、uninterruptible power supply (UPS) systems. X This guide divides the available technologies into the following three main categories: - Vented lead-acid batteries (VLA) - Valve-regulated lead acid (VRLA) - Ni-Cd batteries 名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - -

37、第 5 页,共 11 页 - - - - - - - - - (Ni-Cd) IEEE 450 IEEE Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries for Stationary Applications This document provides recommended maintenance, test schedules, and testing procedures that can be used to optimize the life a

38、nd performance of permanently-installed, vented lead-acid storage batteries used for standby power applications. It also provides guidance to determine when batteries should be replaced. This recommended practice is applicable to full-float stationary applications where a battery charger normally ma

39、intains the battery fully charged and provides the dc loads. However, specific applications, such as emergency lighting units and semi-portable equipment, may have other appropriate practices that are beyond the scope of this recommended practice. X X IEEE 484 Recommended Practice for Installation D

40、esign and Installation of Vented Lead-Acid Batteries for Stationary Applications Recommended practice provides recommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly, assembly, and charging of vented lead-acid batteries. Required safety

41、 practices are also included. This recommended practice is applicable to full float stationary applications where a battery charger normally maintains the battery fully charged and provides the direct current (dc) loads X X X IEEE 1106 IEEE Recommended Practice for Installation, Maintenance, Testing

42、, and Replacement of Vented Nickel-Cadmium Batteries for Stationary Applications This recommended practice provides recommendations for installation design and for installation, maintenance, and testing procedures that can be used to optimize the life and performance of vented nickel cadmium batteri

43、es used in stationary standby applications. This recommended practice also provides guidance for determining when these batteries should be replaced. X X IEEE 1188 IEEE Recommended This recommended practice is limited to maintenance, test schedules, and testing procedures that can be used to X The m

44、aintenance and testing programs described in this recommended practice 名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 6 页,共 11 页 - - - - - - - - - Practice for Maintenance, Testing, and Replacement of Valve-Regulated Lead- Acid (VRLA) Batteries for Stationary Applica

45、tions optimize the life and performance of valve-regulated lead-acid (VRLA) batteries for stationary applications. It also provides guidance to determine when batteries should be replaced. represent “the bestprogram ” based on the information reviewed at the time this document was developed. Station

46、ary cycling applications, such as those found in alternative energy applications, are also beyond the scope of this recommended practice. IEEE 1361 IEEE Guide for Selection, Charging, Test, and Evaluation of Lead-Acid Batteries Used in Stand-Alone Photovoltaic (PV) Systems This guide was written to

47、provide a relevant photovoltaic (PV) battery test procedure that can be used to evaluate battery performance and identify appropriate PV battery charging requirements. X This guide contains a tutorial on lead-acid battery technology, battery charging characteristics, and a laboratory test procedure

48、to evaluate charge parameters and battery performance IEEE 1375 IEEE Guide for the Protection of Stationary Battery SystemsThis document provides guidance in the protection of stationary battery systems. For the purposes of this guide, stationary battery systems include the battery and dc components

49、 to and including the first protective device downstream of the battery terminals. The recommendations provided are not intended to set requirements; rather, they present options to the designer of the battery system concerning the types of protection available. X X Although not a test guide, has so

50、me useful information on battery protection for stationary applications IEEE 1660 IEEE Guide for Application and Management of Stationary Batteries Used in Cycling Service This guide is meant to provide assistance to users of stationary battery systems in determining appropriate battery management s