呼吸机氧电池资料.doc

上传人:豆**** 文档编号:24082001 上传时间:2022-07-03 格式:DOC 页数:71 大小:610.50KB
返回 下载 相关 举报
呼吸机氧电池资料.doc_第1页
第1页 / 共71页
呼吸机氧电池资料.doc_第2页
第2页 / 共71页
点击查看更多>>
资源描述

《呼吸机氧电池资料.doc》由会员分享,可在线阅读,更多相关《呼吸机氧电池资料.doc(71页珍藏版)》请在taowenge.com淘文阁网|工程机械CAD图纸|机械工程制图|CAD装配图下载|SolidWorks_CaTia_CAD_UG_PROE_设计图分享下载上搜索。

1、Four short words sum up what has lifted most successful individuals above the crowd: a little bit more.-author-date呼吸机氧电池资料呼吸机氧电池资料Oxygensensor part nr(定货型号)Output signal in air (空气中输出)Response time T 90% (响应时间)Nominal sensor lifetime (使用寿命)Electrical interface (电路接口类型)主要兼容品牌/型号/代码OOM10146A-63Ano te

2、mperature compensation 500 000 % O2 hoursgold plated slip ringsAnalytical Industries PSR-11-915Biotest S101Catalyst Research MSA (梅思安) 655264Ceramatec CAG-1Draeger 6803290Hamilton (夏美顿) HM-10Hewlett-Packard (HP惠普) 15201-1AHudson 5556IT-Gambert M-01Maxtec (迈克思泰克) MAX-1、MAX-01Datex Ohmeda (欧美达) 4700 O

3、xicap,5250 RGM,Excel Modulus, 5120 Monitor,5125 Monitor,5140,7200,3000/5, 5250,5100,5400, 7800/7810 Vent.Aespira, Avance, Aisys,7800,7810. 0237-2034-700Pacifitech PT-10Paragon Services PS-1000Sensor Tec (BPR Medical) ST-10Sensidyne SV-14ATeledyne C-41131 (R15)Nuova E-15/0VTI (Vascular Technology ) V

4、T1272, 101272 100352OOM1029mV-14mVtemperature compensated 1 000 000 % O2 hours3 pin Molex connector Airshields Isolette (Hill Rom) C2000/C200 8362030ATOM 2100 Incubator 、2000Biotest A103City Technology (城市技术) MOX-1 、MOX-01Criticare (8100 Poet, 8500 Poet)CSI 644 cellDatascope 0600-00-0002Sensor Tec (

5、BPR Medical) ST-12Space Labs 90514Teledyne, Hill-ROM,GE Marquette R22 MEDMaxtec (迈克思泰克) MAX-12AOhmeda Centiva S/5Nuova E-17/A2OOM102-19mV-14mVtemperature compensated 1 000 000 % O2 hours3.5mm mono Jack Analytical Industries PSR-11-917-JATOM OX-60BMD Bio Med Devices M-10, M-2 10006Bird Products (VIAS

6、YS) (鸟牌) 6400 Vent., 8400 Vent., VIP Vent. Catalyst Research MSA (梅思安) MiniOX I,II,III & 3000 406931City Technology (城市技术) MOX-2 、MOX-02Dameca Alpha Med 42035-46Datex-Engstrom Erica 、ElviraHudson 5567IT-Gambert M-15Puritan Bennett (PB泰科)7280 Monitor 7200 Ventilator 4-020933-00Sensor Tec (BPR Medical

7、) ST-11Stephan ArtecTaema (天马) Taema Alys, Claris YR010100Teledyne TED-AX300 (R17 MED)MSA MiniOx 3000Nuova E-15/5OOM1039mV-13mVtemperature compensated 500 000 % O2 hours3 pin Molex connector Criticare PoetMaxtec (迈克思泰克) MAX-22CCTeledyne R22CCNuova E-17/A2OOM103-19mV-13mVtemperature compensated 500 0

8、00 % O2 hours3.5mm mono Jack Invivo 9445Maxtec (迈克思泰克) MAX-13FNuova E-17/JOOM103-1M9mV-13mVtemperature compensated 500 000 % O2 hoursSwitchcraft mini power Jack IT-Gambert M-25Maxtec (迈克思泰克) MAX-250esfOOM10424A-32Ano temperature compensation 750 000 % O2 hoursgold plated slip rings Drager (德尔格) Incu

9、bator 8000 6850645IT-Gambert M-08Sensor Tec (BPR Medical) ST-13Nuova E-8000OOM105Teledyne TED range 500 000 % O2 hoursMolex plug 4P4C Analytical Industries PSR-11-77Catalyst Research MSA (梅思安) 804674City Technology (城市技术) MOX-4 、MOX-04Hamilton (夏美顿) HM-03Hudson 5558IT-Gambert M-07Newport (纽邦) OM100M

10、axtec (迈克思泰克) MAX-17Sechrist 650 / 4370Sensor Tec (BPR Medical) ST-03Teledyne TED 60T/191T/200T T7Nuova E-77/0OOM1069mV-13mVtemperature compensated 1 000 000 % O2 hours3 pin Molex connectorDatascope 0600-00-0002Maxtec (迈克思泰克) MAX-12FNuova O-17/M1OOM107170A-230Ano temperature compensation 250 000 % O

11、2 hoursgold plated slip rings Catalyst Research MSA (梅思安) 485905Hamilton (夏美顿) Arabella, Amadeus, Veolar HM-01Hudson 5569IT-Gambert M-05Maxtec (迈克思泰克) MAX-19Megamed M2Pacifitech PT-01Sensor Tec (BPR Medical) ST-01Teledyne No leads T1/T2Nuova E-33/0OOM107-2170A-230Ano temperature compensation 250 000

12、 % O2 hoursflying leads with pin-connectors Analytical Industries PSR-11-33Bio Tek (宝待) 48351Catalyst Research MSA (梅思安) 478841Hudson 5568IT-Gambert M-06Maxtec (迈克思泰克) MAX-18Megamed M1Pacifitech PT-02Sensor Tec (BPR Medical) ST-02Teledyne With leads C1R/ C2RVickers MieNuova E-33/1OOM11010mV-12mVtemp

13、erature compensated 1 000 000 % O2 hoursmodular Jack 6P4CCity Technology (城市技术) MOX-7 、MOX-07IT-Gambert M-10Maxtec (迈克思泰克) MAX-10Ohmeda (欧美达) Aestiva, 7900 Monitor, Excel SE 6050-0004-110OOM20124A-32A (dual cathode)no temperature compensation 500 000 % O2 hoursgold plated slip rings Analytical Indus

14、tries PSR-11-915-2Catalyst Research MSA (梅思安) 655263Ceramatec CAG-11City Technology (城市技术) MOX-16DP Medical MVA210Drager (德尔格) Cicero, Cato, Babylog, Sulla, Oxycom, Oxydig, Evita 2 & 4, Anemone, Evita Dura, Cicero, Babylog, Fabian, PM8030, Anemone, Incubator 8000 , I-8000, 8000IC, Fabius GS, Narcome

15、d 1A,2,2B,3,4 6850645NAD Narcomed 6850645Hamilton (瑞士哈美顿/夏美顿) HM-13、HM-14Hewlett Packard (HP惠普) 15201A Hudson 5557 , V-14IT-Gambert M-02Maxtec (迈克思泰克) MAX-11Mercury Medical 10-103-07Ohmeda O2 cell 6051-0000-224Oxitron 3710Pacifitech PT-14Paragon Services PS-2000PPG Biomedical, Irisa 505055-001Sensor

16、 Tec (BPR Medical) ST-14Sensidyne SV-14ATeledyne R23 , R23MEDVascular Technology 101372Ventrex V-14ANuova E-15/2OOM20213mV-16mVtemperature compensated 1 000 000 % O2 hours3 pin Molex Analytical Industries PSR-11-917-MBird Products (VIASYS) (鸟牌) Avea. VentCatalyst Research MSA (梅思安) 472062 , 470644Ce

17、ramatec CAG-12City Technology (城市技术) MOX-9 、MOX-09EME, Infant FlowHamilton (瑞士哈美顿/夏美顿) Galileo (伽利略),Raphael (拉斐尔), Alladin HM-12 , 51214Hudson 5566Infrasonics Adult Star 601T , 60116IT-Gambert M-04 、M-16Maxtec (迈克思泰克) MAX-12 、MAX-16Mercury Medical 10-103-06Ohmeda O2 cell 6051-0000-222Pacifitech PT-

18、12Puritan Bennett (PB泰科) Ventilators 840, 740, 760 4-072214-00PPG Biomedical Saracap 504055-001Sensidyne SV-12ASensor Tec (BPR Medical) ST-12, ST-04Siemens (西门子) Servo Ventilators, 900, 900C, 900D, 700, 710, 300, V710300 , 9004979 , 6419332Space Labs 90514 , Gas Analyzer 015-0132-03Taema (天马) YR0497

19、00, Cesar 2, HorusTeledyne R24 , R24MED , Cheiron R-24 , Hill-ROM R-24Vascular Technology 103100Ventrex V-12AVTI 103100Nuova E-17/MOOM202-113mV-16mVtemperature compensated 1 000 000 % O2 hours3.5mm mono Jack Analytical Isolette 6735142IT-Gambert M-03Maxtec (迈克思泰克) MAX-13OOM202-213mV-16mVtemperature

20、compensated 1 000 000 % O2 hoursflying leads with 3pin female molex connector Catalyst Research MSA (梅思安) MiniOX IA 806572IT-Gambert M-09Maxtec (迈克思泰克) MAX-14Nuova E-09/0OOM202-2S9mV-11,5mVtemperature compensated 1 000 000 % O2 hoursAMP MATE-N-LOK/2 circuit City Technology (城市技术) MOX-10IT-Gambert M-

21、11Stephan Stephanie (斯迪芬妮)Generelle spesifikasjoner (alle O2-sensorer):Measurement range (测量范围)0-100% oxygenAccuracy and repeatability (精度及重复性)1% vol.O2 when calibrated at 100% O2Zero offset (零点飘移)0,5% vol.O2 in 100% N2, applied 5 minutesLinearity error (线性误差)3% realtiveCross interference (交叉干扰)0,5%

22、 vol.O2 response to: 10% CO2 balance N280% N2O balance N27,5% Halothane balance N27,5% Isoflurane balance N27,5% Enflurane balance N29% Sevoflurane balance N220% Desflurane balance N2Influence of humidity (温度的影响)-0.03% rel. per % RH at 25CInfluence of pressure (压力的影响)proportional to change in oxygen

23、 partial pressureInfluence of mechanical shock (机械冲击影响)1% relative after fall from 1mOperating temperature (工作温度)0 to 50CTemperature compensation (温度补偿)built-in NTC compensation (depends on type)Effect of temperature compensation (steady state) 温度影响补偿(稳态)between +20C and +40C: 3% relative error betw

24、een 0C and +50C: 5% relative errorOperating humidity (工作湿度)0-99% RH non condensingLong term output drift (长期输出漂移)1% vol oxygen per month, typically - 10 kOhmsWarm-up time (预热时间)30 minutes, after replacement of sensorWeight (重量)aprrox 28 grams, approx 43 grams OOM107 series包装方式:德国制造,铝盒密封,产品稳定可靠,运输储存方便长久-

展开阅读全文
相关资源
相关搜索

当前位置:首页 > 教育专区 > 小学资料

本站为文档C TO C交易模式,本站只提供存储空间、用户上传的文档直接被用户下载,本站只是中间服务平台,本站所有文档下载所得的收益归上传人(含作者)所有。本站仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。若文档所含内容侵犯了您的版权或隐私,请立即通知淘文阁网,我们立即给予删除!客服QQ:136780468 微信:18945177775 电话:18904686070

工信部备案号:黑ICP备15003705号© 2020-2023 www.taowenge.com 淘文阁