《外文翻译-zigbee检测探头在冷藏蔬菜运输现实条件下的测试大学论文.doc》由会员分享,可在线阅读,更多相关《外文翻译-zigbee检测探头在冷藏蔬菜运输现实条件下的测试大学论文.doc(20页珍藏版)》请在taowenge.com淘文阁网|工程机械CAD图纸|机械工程制图|CAD装配图下载|SolidWorks_CaTia_CAD_UG_PROE_设计图分享下载上搜索。
1、中文4250字学校代码: 10128学 号: 本科毕业设计 外文文献及翻译(英文题目:Testing ZigBee Motes for Monitoring Refrigerated Vegetable Transportation under Real Conditions 中文题目:ZigBee检测探头在冷藏蔬菜运输现实条件下的测试学生姓名:学 院:信息工程学院系 别:电子信息工程专 业:班 级:指导教师: 教授二 一 年 月AbstractQuality control and monitoring of perishable goods during transportation an
2、d delivery services is an increasing concern for producers, suppliers, transport decision makers and consumers. The major challenge is to ensure a continuous cold chain from producer to consumer in order to guaranty prime condition of goods. In this framework, the suitability of ZigBee protocol for
3、monitoring refrigerated transportation has been proposed by several authors. However, up to date there was not any experimental work performed under real conditions. Thus, the main objective of our experiment was to test wireless sensor motes based in the ZigBee/IEEE 802.15.4 protocol during a real
4、shipment. The experiment was conducted in a refrigerated truck traveling through two countries (Spain and France) which means a journey of 1,051 kilometers. The paper illustrates the great potential of this type of motes, providing information about several parameters such as temperature, relative h
5、umidity, door openings and truck stops. Psychrometric charts have also been developed for improving the knowledge about water loss and condensation on the product during shipments.1. IntroductionPerishable food products such as vegetables, fruit, meat or fish require refrigerated transportation. For
6、 all these products, Temperature (T) is the most important factor for extending shelf life, being essential to ensure that temperatures along the cold chain are adequate. However, local temperature deviations can be present in almost any transport situation. Reports from the literature indicate grad
7、ients of 5 C or more, when deviations of only a few degrees can lead to spoiled goods and thousands of Euros in damages. A recent study shows that refrigerated shipments rise above the optimum temperature in 30% of trips from the supplier to the distribution centre, and in 15% of trips from the dist
8、ribution centre to the stores. Roy et al. analyzed the supply of fresh tomato in Japan and quantified product losses of 5% during transportation and distribution. Thermal variations during transoceanic shipments have also been studied. The results showed that there was a significant temperature vari
9、ability both spatially across the width of the container as well as temporally along the trip, and that it was out of the specification more than 30% of the time. In those experiments monitoring was achieved by means of the installation of hundreds of wired sensors in a single container, which makes
10、 this system architecture commercially unfeasible.Transport is often done by refrigerated road vehicles and containers equipped with embedded cooling systems. In such environments, temperatures rise very quickly if a reefer unit fails. Commercial systems are presently available for monitoring contai
11、ners and trucks, but they do not give complete information about the cargo, because they typically measure only temperature and at just one point.Apart from temperature, water loss is one of the main causes of deterioration that reduces the marketability of perishable food products. Transpiration is
12、 the loss of moisture from living tissues. Most weight loss of stored fruit is caused by this process. Relative humidity (RH), T of the product, T of the surrounding atmosphere, and air velocity all affect the amount of water lost in food commodities. Free water or condensation is also a problem as
13、it encourages microbial infection and growth, and it can also reduce the strength of packaging materials.Parties involved need better quality assurance methods to satisfy customer demands and to create a competitive point of difference. Successful transport in food logistics calls for automated and
14、efficient monitoring and control of shipments. The challenge is to ensure a continuous cold chain from producer to consumer in order to guaranty prime condition of goods . The use of wireless sensors in refrigerated vehicles was proposed by Qingshan et al. as a new way of monitoring. Specialized WSN
15、 (Wireless Sensor Network) monitoring devices promise to revolutionize the shipping and handling of a wide range of perishable products giving suppliers and distributors continuous and accurate readings throughout the distribution process. In this framework, ZigBee was developed as a very promising
16、WSN protocol due to its low energy consumption and advanced network capabilities. Its potential for monitoring the cold chain has been addressed by several authors but without real experimentation, only theoretical approaches. For this reason, in our work real experimentation with the aim of explori
17、ng the limits of this technology was a priority.The main objective of this project is to explore the potential of wireless ZigBee/IEEE 802.15.4 motes for their application in commercial refrigerated shipments by road. A secondary objective was to improve the knowledge about the conditions that affec
18、t the perishable food products during transportation, through the study of relevant parameters like temperature, relative humidity, light, shocking and psychrometric properties.2. Materials and Methods2.1. ZigBee MotesFour ZigBee/IEEE 802.15.4 motes (transmitters) and one base station (receiver) wer
19、e used. All of them were manufactured by Crossbow. The motes consist of a microcontroller board (Micaz) together with an independent transducer board (MTS400) attached by means of a 52 pin connector. The Micaz mote hosts an Atmel ATMEGA103/128L CPU running the Tiny Operating System (TinyOS) that ena
20、bles it to execute programs developed using the nesC language. The Micaz has a radio device Chipcon CC2420 2.4 GHz 250 Kbps IEEE 802.15.4. Power is supplied by two AA lithium batteries.The transducer board hosts a variety of sensors: T and RH (Sensirion SHT11), T and barometric pressure (Intersema M
21、S5534B), light intensity (TAOS TSL2550D) and a two-axis accelerometer (ADXL202JE). A laptop computer is used as the receiver, and communicates with the nodes through a Micaz mounted on the MIB520 ZigBee/USB gateway board.Each Sensirion SHT11 is individually calibrated in a precision humidity chamber
22、. The calibration coefficients are used internally during measurements to calibrate the signals from the sensors. The accuracies for T and RH are 0.5 C (at 25 C) and 3.5% respectively.The Intersema MS5534B is a SMD-hybrid device that includes a piezoresistive pressure sensor and an ADC-Interface IC.
23、 It provides a 16 bit data word from a pressure and T (40 to +125C) dependent voltage. Additionally the module contains six readable coefficients for a highly accurate software calibration of the sensor.The TSL2550 is a digital-output light sensor with a two-wire, SMBus serial interface. It combines
24、 two photodiodes and an analog-to digital converter (ADC) on a single CMOS integrated circuit to provide light measurements over a 12-bit dynamic range. The ADXL202E measures accelerations with a full-scale range of 2 g. The ADXL202E can measure both dynamic acceleration (e.g., vibration) and static
25、 acceleration (e.g., gravity).2.2. Experimental Set UpThe experiment was conducted in a refrigerated truck traveling during 23 h 41 m 21 s from Murcia (Spain) to Avignon (France), a distance of 1,051 km. The truck transported approx.14,000 kg of lettuce var. Little Gem in 28 pallets of 1,000 1,200 m
26、m . The lettuce was packed in cardboard boxes with openings for air circulation. The length of the semi-trailer was 15 m with a Carrier Vector 1800 refrigeration unit mounted to the front of the semi-trailer. For this shipment the set point was 0 C.The truck was outfitted with the wireless system, c
27、overing different heights and lengths from the cooling equipment, which was at the front of the semi-trailer. Four motes were mounted with the cargo (see Figure 1): mote 1 was at the bottom of the pallets in the front side of the semi-trailer, mote 2 was in the middle of the semi-trailer, mote 3 was
28、 in the rear at the top of the pallet, and mote 4 was located as shown in Figure 1, about a third of the distance between the front and the rear of the trailer. Motes 1, 2 and 3 were inside the boxes beside the lettuce. The program installed in the motes collects data from all the sensors at a fixed
29、 sample rate (7.2 s), with each transmission referred to as a “packet”. The RF power in the Micaz can be set from 24 dBm to 0 dBm. During the experiment, the RF power was set to the maximum, 0dBm (1mW approximately).2.3. Data AnalysisA specialized MATLAB program has been developed for assessing the
30、percentage of lost packets (%) in transmission, by means of computing the number of multiple sending failures for a given sample rate (SR). A multiple failure of m messages occurs whenever the elapsed time between two messages lies between 1.5 m SR and 2.5 m SR. For example, with a sample rate of 11
31、 s, a single failure (m = 1) occurs whenever the time period between consecutives packets is longer than 16.5 s (1.5 1 11) and shorter than 27.5 s (2.5 1 11). The total number of lost packets is computed based on the frequency of each failure type. Accordingly, the total percentage of lost packets i
32、s calculated as the ratio between the total number of lost packets and the number of sent packets.The standard error (SE) associated to the ratio of lost packets is computed based on a binomial distribution as expressed in Equation 1, where n is the total number of packets sent, and p is the ratio o
33、f lost packets in the experiment.2.4. Analysis of VarianceFactorial Analysis of Variance (ANOVA) was performed in order to evaluate the effect of the type of sensor in the registered measurements, including T (by means of Sensirion and Intersema), RH, barometric pressure, light intensity and acceler
34、ation module. ANOVA allows partitioning of the observed variance into components due to different explanatory variables. The STATISTICA software (StatSoft, Inc.) was used for this purpose 14. The Fisherss F ratio compares the variance within sample groups (“inherent variance”) with the variance betw
35、een groups (factors). We use this statistic for knowing which factor has more influence in the variability of the measurements.2.5. Psychrometric DataPsychrometry studies the thermodynamic properties of moist air and the use of these properties to analyze conditions and processes involving moist air
36、. Psychrometric charts show a graphical representation of the relationship between T, RH and water vapor pressure in moist air. They can be used for the detection of water loss and condensation over the product.In our study, the ASAE standard D271.2 was used for computing the psychrometric propertie
37、s of air. Equations 25 and Table 1 enable the calculation of all psychrometric data of air whenever two independent psychrometric properties of an air-water vapour mixture are known in addition to the atmospheric pressure:where Ps stands for saturation vapor pressure (Pa), T is the temperature (K),
38、Pv is the vapor pressure (Pa), H the absolute humidity (g/kg dry air), Patm is atmospheric pressure (Pa) and A, B, C, D, E, F, G and R are a series of coefficients used to compute Ps, according to Equation 3.3. Results and Discussion3.1. Reliability of TransmissionSignal propagation through the lett
39、uce lead to absorption of radio signals, resulting in great attenuations in RF signal strength and link quality at the receiver. During the experiment, only motes 3 and 4 were able to transmit to the coordinator. No signals were received from mote number 1, at the bottom of the first pallet, and num
40、ber 2, in the middle of the pallet. Mote 3 was closer to the coordinator than mote 4, but mote 3 was surrounded by lettuce which blocks the RF signal. However between mote 4 and the coordinator there was free space for transmission. Thus, the maximum ratio of lost packets found was 100% for two of t
41、he motes and the minimum 4.5% 0.1%, for mote 4.Similar ratios were reported by several authors who performed experiments with WSN under real conditions, like for example in monitoring vineyards. Also, Baggio and Haneveld, after one year of experimentation in a potato field using motes operating at t
42、he band of 868/916MHz, reported that 98% of data packets were lost. However, during the second year the total amount of data gathered was 51%, which represents a clear improvement. Ipema et al. monitored cows with Crossbow motes, and found that the base station directly received less than 50% of tem
43、perature measurements stored in the mote buffer. Nadimi et al., who also monitored cows with this type of motes, showed packet loss rates of about 25% for wireless sensor data from cows in a pasture even the distance to the receiver (gateway) was less than 12.5 m away. Radio propagation can be influ
44、enced by two main factors: the properties of propagation media and the heterogeneous properties of devices. In a commercial shipment, if the motes are embedded within the cargo, a significant portion of the Fresnel zone is obstructed. This is a big challenge in our application. Changing the motes lo
45、cation, for example the one at the bottom of the pallets (mote 1, at the front of the semitrailer) or the one in the middle of the compartment (mote 2), might have yielded in better data reception rates but would have resulted in a loss of spatial information near the floor or at mid-height. The sen
46、sors should be as close as possible to the products transported; otherwise the measurements would not give precise information. Thus, one solution, if the same motes are to be used, could be to include intermediates motes that allow peer to peer communication to the base station. Another solution co
47、uld be to use lower frequencies; however this is not possible using ZigBee, because the only radio frequency band available for ZigBee worldwide is the 2.4 GHz one. The other ISM (Industrial, Scientific and Medical) bands (868 MHz and 915 MHz) differ from USA to Europe. Other options include develop
48、ing motes with more RF power that can achieve longer radio ranges. The transmission could also be improved by optimizing antenna orientation, shape and configuration. The standard antenna mounted in the Micaz is a 3 cm long 1/2 wavelength dipole antenna. The communications could be enhanced using ceramic collinear antennas or with use of a simple reflecting screen to supplement a primary antenna, which can provide a 9dB improvement. Link asymmetry and an irregular radio range can be caused by the antenna position. In a real envir