1、FANUC 18P Communications Amada America,Inc.Print Date 02/24/03 Revision 5.1 Page 1 of 23 This document available on the World Wide Web at http:/ FANUC 18P Communications For Machine Models Vipros 255,Pega 255,Vipros 2510 King Vipros 358 King Type II,Vipros 368 King Type II Vipros 357 Queen,Vipros 36

2、7 Queen Amada America,Inc.7025 Firestone Blvd.Buena Park,CA 90621 Phone:714-739-2111 Fax:714-739-4099 e-mail: FANUC 18P Communications Amada America,Inc.Print Date 02/24/03 Revision 5.1 Page 2 of 23 This document available on the World Wide Web at http:/ Contents Setting I/O channel for floppy disk

3、or RS-232 communication.3 Transferring a Program to Control Memory from Floppy Disk.4 Transferring a Program to Control Memory from a PC.5 Transferring a Program to Control Memory from a PC using Windows9x/2000 HyperTerminal*Program.6 Transferring a Program from Control Memory to a Floppy Disk.9 Tra

4、nsferring a Program from Control Memory to a PC using RS-232 connection.10 Transferring a Program from Control Memory to a PC using Windows9x/2000 HyperTerminal Program.11 Configuring Parameters for RS 232 Communication.13 Configuring Parameters to Communicate with the Internal Floppy Disk.15 Config

5、uring Windows9x/2000 HyperTerminal Program to Communicate with the Fanuc 18P Control.17 Fanuc 18P Control Floppy Scheduler Operation.20 Communications Block Diagram.22 Cables.23 FANUC 18P Communications Amada America,Inc.Print Date 02/24/03 Revision 5.1 Page 3 of 23 This document available on the Wo

6、rld Wide Web at http:/ Setting I/O channel for floppy disk or RS-232 communication.Before attempting transfer of programs to/from the control,please confirm that the appropriate I/O channel has been selected in the Fanuc 18 P control.Switch the EDIT PROTECT Key-switch to the OFF position.Press MDI M

7、ode pushbutton.Press the SET pushbutton.Press SETTING softkey.Press UP pushbutton or DOWN pushbutton to highlight I/0 CHANNEL.Change I/0 CHANNEL value to 0,1 or 2 by pressing the NUMBER 0(or 1 or 2)pushbutton and then the INPUT pushbutton.(see table below)or or INPUT Use the values in the following

8、table to determine the correct I/O Channel setting.Machine Model Vipros 255 Vipros 2510 King Vipros 558 King Type IIVipros 368 King Type IIVipros 357 Queen Vipros 367 Queen Pega 255 RS-232:1 1 1 1 2 2 1 Floppy Disk:0 0 0 0 0 0 0 FANUC 18P Communications Amada America,Inc.Print Date 02/24/03 Revision

9、 5.1 Page 4 of 23 This document available on the World Wide Web at http:/ Transferring a Program to Control Memory from Floppy Disk This procedure is used to transfer a G-code part program to the Fanuc 18P Control memory from a floppy disk.Before beginning,check that the communication parameters are

10、 set as described in the section Configuring Parameters to Communicate with Internal Floppy Disk on page 15 of this document.Set correct I/O setting as instructed in the first section of this document.At the Fanuc 18P Control:Place floppy disk in floppy drive and close door(door must be closed!).Tur

11、n EDIT PROTECT Key switch to the OFF position.Press the EDIT mode switch Press PROG pushbutton.Press the+NEXT MENU softkey.Press the FLOPPY softkey.Press the PAGE UP ARROW pushbutton.Press the(OPRT)softkey.Press the READ softkey.Enter the displayed file number that you wish to load,and press the F S

12、ET softkey.If the part program does not contain an O Number in the G-code,enter a four-digit number and press the O SET softkey.Press the EXEC softkey.If there is not a“%”at the end of the actual G-code program it will be necessary to press the STOP softkey to end the transmission.FANUC 18P Communic

13、ations Amada America,Inc.Print Date 02/24/03 Revision 5.1 Page 5 of 23 This document available on the World Wide Web at http:/ Transferring a Program to Control Memory from a PC The following conditions must exist to use this procedure:Check that the communication parameters are set as described in

14、the section Configuring Parameters for RS 232 Communication”Connect the PC communications port to the Fanuc 18P Control RS232 Port.See the section Cables(page 23)of this document for correct cable configuration.At the Fanuc 18P Control:Set correct I/O setting as instructed in the first section of th

15、is document.Press the EDIT mode switch Press the PROG pushbutton Press the DIR softkey Confirm that none of the part program numbers(i.e.O1234)that are to be downloaded currently exist in the Fanuc 18P Control memory.Press the(OPRT)softkey Press the+NEXT MENU softkey Press the EXEC softkey When comm

16、unications are finished the control will display the downloaded program.If the downloaded program does not contain a%sign as the last line of the G-code it will be necessary to press the STOP button to end communications.FANUC 18P Communications Amada America,Inc.Print Date 02/24/03 Revision 5.1 Pag

17、e 6 of 23 This document available on the World Wide Web at http:/ Transferring a Program to Control Memory from a PC using Windows9x/2000 HyperTerminal*Program.This procedure is used to transfer a G-code part program to the Fanuc 18P Control memory from a PC using the Windows HyperTerminal program.H

18、yperTerminal is included with Windows 9x/2000 and can be found in the“Accessories/communications”category.If it does not appear there,it may be necessary to install it from the original Windows installation disks.The following conditions must exist to use this procedure:Connect the communications ca

19、ble between the computer and the Fanuc 18P Control RS232 connector.See the section Cables(page 23)of this document for correct cable configuration.Use the Amada standard RS232 Cable configuration.Configure the Fanuc 18P Control communication parameters for RS 232 Communication See the section Config

20、uring Parameters for RS 232 Communication.Configure the Windows9x/2000 HyperTerminal program to communicate with the Fanuc 18P Control.See the section Configuring Windows HyperTerminal Program to Communicate with the Fanuc 18P Control(page 17)of this document.*NOTE:Windows HyperTerminal is known to

21、have problems and in some circumstances may not work correctly.It is recommended that a newer version be installed if any problems are encountered.A free upgrade can be downloaded from this site:http:/ The newer version is known as“HyperTerminal Private edition”.At the PC:Open the Windows9x/2000 Hyp

22、erTerminal Program FANUC18P FANUC 18P Communications Amada America,Inc.Print Date 02/24/03 Revision 5.1 Page 7 of 23 This document available on the World Wide Web at http:/ Select a file to send to the Fanuc 18P Control by:Select:Transfer Send Text File At the 18P control:Prepare the control to rece

23、ive the program as directed in the section on“Transfering a program to control memory from a PC”.Select the Drive,Directory,and File to download to the Fanuc 18P Control.Select Open to download the file.The part program will scroll across the screen until transmission is complete.FANUC 18P Communica

24、tions Amada America,Inc.Print Date 02/24/03 Revision 5.1 Page 8 of 23 This document available on the World Wide Web at http:/ Stop the transmission sequence by:Select Call Disconnect At the Fanuc 18P Control:When the Transmission is complete the downloaded program will be displayed.FANUC 18P Communi

25、cations Amada America,Inc.Print Date 02/24/03 Revision 5.1 Page 9 of 23 This document available on the World Wide Web at http:/ Transferring a Program from Control Memory to a Floppy Disk This procedure is used to transfer a G-code program from the Fanuc 18P Control memory to a floppy disk.Check tha

26、t the communication parameters are set as described in the section Configuring Parameters to Communicate with Internal Floppy Disk(page 15)of this document.At the Fanuc 18P Control:Set correct I/O setting as instructed in the first section of this document.Place floppy disk in floppy drive and close

27、 door.Set FD/EXTERNAL switch to FD.Turn EDIT PROTECT Key switch to the OFF position.Press EDIT MODE pushbutton.Press PROG pushbutton.Press DIR softkey.Press(OPRT)softkey.Press the letter O and the four-digit part program number to transfer.and the four-digit part program number Press the+NEXT MENU s

28、oftkey.Press the PUNCH softkey.Press the EXEC softkey.FANUC 18P Communications Amada America,Inc.Print Date 02/24/03 Revision 5.1 Page 10 of 23 This document available on the World Wide Web at http:/ Transferring a Program from Control Memory to a PC using RS-232 connection.This procedure is used to

29、 transfer a G-code part program from the Fanuc 18P Control memory to a PC using the RS-232 connection and suitable communication software.Check that the communication parameters are set as described in the section“Configuring parameters for RS-232 communication”.Connect the PC communications port to

30、 the Machine RS232 Port.See the section Cables(page 23)of this document for correct cable configuration.At the Fanuc 18P Control:Set correct I/O setting as instructed in the first section of this document.Switch FD/EXTERNAL switch to External.Turn EDIT PROTECT Key switch to the OFF position.Press th

31、e EDIT Mode pushbutton Press the PROG pushbutton Press the DIR softkey Press the(OPRT)softkey Press the+NEXT MENU softkey Type the letter O and the four-digit part program number as displayed in the directory listing Prepare the communication software on the PC to receive the program.(Refer to docum

32、entation supplied with the communication software)Press the PUNCH softkey Press the EXEC softkey FANUC 18P Communications Amada America,Inc.Print Date 02/24/03 Revision 5.1 Page 11 of 23 This document available on the World Wide Web at http:/ Transferring a Program from Control Memory to a PC using

33、Windows9x/2000 HyperTerminal Program This procedure is used to transfer a G-code part program from the Fanuc 18P Control memory to a PC using the Windows9x/2000 HyperTerminal program.Connect the communications cable between the computer and the RS232 connector on the Fanuc 18P Control.See the sectio

34、n Cables(page 23)of this document for correct cable configuration.Use the Amada standard RS232 Cable configuration.Configure the Fanuc 18P Control communication parameters.See the section Configuring Parameters for RS-232.Configure the Windows9x/2000 HyperTerminal program to communicate with the Fan

35、uc 18P Control.See the section Configuring Windows HyperTerminal Program to Communicate with the Fanuc 18P Control(page 17)of this document.*NOTE:Windows HyperTerminal is known to have problems and in some circumstances may not work correctly.It is recommended that a newer version be installed if an

36、y problems are encountered.A free upgrade can be downloaded from this site:http:/ The newer version is known as“HyperTerminal Private edition”.At the PC:Open the Windows9x/2000 HyperTerminal Program FANUC18P.FANUC 18P Communications Amada America,Inc.Print Date 02/24/03 Revision 5.1 Page 12 of 23 Th

37、is document available on the World Wide Web at http:/ To receive a file from the Fanuc 18P Control:Select:Transfer Capture Text Enter the part program file path and name.Select Start to begin reception.At the Control:Begin sending the program to the computer.See section on”Transfering a Program from

38、 Control Memory to a PC using RS-232 connection.”The part program will scroll across the screen until transmission is complete.Stop the transmission sequence by:Select:Call Disconnect FANUC 18P Communications Amada America,Inc.Print Date 02/24/03 Revision 5.1 Page 13 of 23 This document available on

39、 the World Wide Web at http:/ Configuring Parameters for RS 232 Communication This procedure configures the Fanuc 18P Control to communicate through the RS-232 connection using a communication software application.At the Fanuc 18P Control:Press MDI Mode pushbutton.Turn EDIT PROTECT Key switch to the

40、 OFF position.Press the SET pushbutton.Press SETTING softkey.Press PAGE UP pushbutton or PAGE DOWN pushbutton until display changes to read SETTING(HANDY).Press UP pushbutton or DOWN pushbutton to highlight PARAMETER WRITE.Change PARAMETER WRITE value to 1 by pressing the NUMBER 1 pushbutton and the

41、n the INPUT pushbutton.An alarm will be generated at this point.Ignore the alarm,but be careful not to alter any parameters other than what is described here.INPUT Press OFFSET SETTING pushbutton.Press SYSTEM pushbutton.Press PARAM softkey.Press PAGE UP pushbutton or PAGE DOWN pushbutton until displ

42、ay reads PARAMETER(RS232C INTERFACE).Press the UP pushbutton or DOWN pushbutton to highlight parameter 0100.Set the parameter to value 00001000 by pressing the RIGHT or LEFT pushbutton to highlight the individual parameter bit and pressing the correct numeral pushbutton to FANUC 18P Communications A

43、mada America,Inc.Print Date 02/24/03 Revision 5.1 Page 14 of 23 This document available on the World Wide Web at http:/ change the value.Press the INPUT pushbutton.INPUT Press the UP pushbutton or DOWN pushbutton to highlight parameter 0111.Set the parameter to value 10000001 by pressing the RIGHT o

44、r LEFT pushbutton to highlight the individual parameter bit and pressing the correct numeral pushbutton to change the value.Press the INPUT pushbutton.INPUT Press the UP pushbutton or DOWN pushbutton to highlight parameter 0112.Set the DEVICE NUM parameter to value 0 by pressing the RIGHT or LEFT pu

45、shbutton to highlight the parameter bit and pressing the correct numeral pushbutton to change the value.Press the INPUT pushbutton.INPUT Press the UP pushbutton or DOWN pushbutton to highlight parameter 0113.Set the BAUDRATE(CH1)parameter to correct value by pressing the RIGHT or LEFT pushbutton to

46、highlight the parameter bit and pressing the correct numeral pushbutton to change the parameter value.See page 22 for baud rate settings.Press the INPUT pushbutton.INPUT Press SET pushbutton.Press UP pushbutton or DOWN pushbutton to highlight PARAMETER WRITE.Change PARAMETER WRITE value to 0 by pres

47、sing the number 0 pushbutton and then the INPUT pushbutton.INPUT Press the RESET pushbutton to reset ALARM 100.FANUC 18P Communications Amada America,Inc.Print Date 02/24/03 Revision 5.1 Page 15 of 23 This document available on the World Wide Web at http:/ Configuring Parameters to Communicate with

48、the Internal Floppy Disk This procedure is used to configure the Fanuc 18P Control to communicate with the internal floppy disk drive.At the Fanuc 18P Control:Press MDI Mode pushbutton.Turn EDIT PROTECT Key switch to the OFF position.Press OFFSET SETTING pushbutton.Press SETTING softkey.Press PAGE U

49、P pushbutton or PAGE DOWN pushbutton until display changes to read SETTING(HANDY).Press UP pushbutton or DOWN pushbutton to highlight PARAMETER WRITE.Change PARAMETER WRITE value to 1 by pressing the NUMBER 1 pushbutton and then the INPUT pushbutton.An alarm will be generated at this point.Ignore th

50、e alarm,but be careful not to alter any parameters other than what is described here.INPUT Press SYSTEM pushbutton.Press PARAM softkey.Press PAGE UP pushbutton or PAGE DOWN pushbutton until display reads PARAMETER(RS232C INTERFACE).Press the UP pushbutton or DOWN pushbutton to highlight parameter 01