《180kW自动化柴油发电机组技术规格书.doc》由会员分享,可在线阅读,更多相关《180kW自动化柴油发电机组技术规格书.doc(11页珍藏版)》请在taowenge.com淘文阁网|工程机械CAD图纸|机械工程制图|CAD装配图下载|SolidWorks_CaTia_CAD_UG_PROE_设计图分享下载上搜索。
1、 潍柴重机(潍坊)发电设备有限公司180kW柴油发电机组技术规格书Technical Specification of 180kW Diesel Generating Set 潍柴重机(潍坊)发电设备有限公司Weichai Heavy machinery Co.,Ltd.目录Contents1. 机组介绍Introduction2. 输出功率描述Output description3. 执行标准Implementation of standards4. 环境条件Environmental conditions5. 机组的主要技术规格Main technical specifications6.
2、 机组主要性能指标Main performances7. 机组配置Unit configuration8. 机组结构Structure9. 供货范围Scope of supply1. 机组介绍IntroductionWPG247.5B8型柴油发电机组采用潍柴WD10系列柴油机、无锡星诺电气有限公司生产的三相交流发电机、公共底盘和控制屏等组成。WD247.5/8 diesel generating set is composed of Weichai WD10series diesel engine, three-phase AC generator of Wuxi shine Electric
3、al Ltd., a common chassis , control panel, and so on.2. 输出功率描述Output description持续功率:机组在变动负载工况下连续运行的功率。我公司的机组功率按此功率标定。Continuous power: Unit continuous operating power in variable load conditions. Our gen-sets according to the power calibration.3. 标准Implementation of standards机组的设计、制造符合下列标准:Manufact
4、uring and design meet the following criteria:GB/T 20136-2006内燃机电站通用试验方法General method of test for electric power plant with internal combustion enginesJB/T 50054-1999内燃机电站 可靠性考核评定方法Internal combustion engine power reliability evaluation methodJB/T 10303-2001工频柴油发电机组技术条件Technical requirements for ind
5、ustrial diesel gen-setsGB/T 2820-2008 往复式内燃机驱动的交流发电机组AC reciprocating internal combustion engine driven generating sets系列标准serial standards.JB/T 6755-1993 柴油发电机组成套开关设备Diesel generator set switch equipmentJB/T 8194-2001 内燃机电站术语Terminology for electric power plant with internal combustion engine4环境条件E
6、nvironmental conditions4.1机组在下列条件下,应能输出额定功率:Units under the following conditions, should be able to output the rated power :a) 绝对大气压力,PX:100kPa(或海拔高度0米);Absolute atmospheric pressure, PX: 100kPa (Or 0 meters above sea level)b) 环境温度,Tr:298K(25);Environmental temperature, Tr: 298K (25)c) 空气相对湿度r:30%。
7、Relative humidity of the airr:30%.4.2 机组在下列条件下,应能输出规定功率(允许修正功率)并可靠地工作:Units under the following conditions, should be able to output regulation power (allows the correction power) and work reliably:a)海拔高度不超过1000m;The altitude does not exceed 1000 meters;b)环境温度:下限值5,上限值40;Environmental temperature: L
8、ower limit value 5,upper limit value 40; c)空气相对湿度:最湿月平均最高相对湿度为90%(25)1)Relative humidity of the air: The wettest month average maximum relative humidity is 90%(25)注:1)指该月的月平均最低温度为25,月平均最低温度是指该月每天最低温度的月平均值。Notes: 1) The monthly mean minimum temperature is 25, the monthly mean minimum temperature is t
9、he average daily minimum temperature of the month.5.机组的主要技术规格Main technical specifications序号NO.项目Item参数reference1机组型号ModelWPG247.5B82额定功率Rated power180kW4额定电压Rated voltage400V5额定电流Rated current324A4额定频率Rated frequency50Hz5额定功率因数Rated power factor0.8(滞后lag)6额定转速Rated speed1500r/min7励磁方式Excitation typ
10、e无刷自励Brushless excitation8启动方式Start methodDC24V电马达起动electrical start9冷却方式Cooling mode闭式风扇水冷Closed fan water-cooling10重量Weight2077kg11外形尺寸Size and shape283510901937(mm)6.机组主要性能指标:Main performances序号NO.参数reference单位Unit运行极限值Operational limit附注remarks1频率降Frequency drop%52稳态频率带Steady state frequency ban
11、d%1.53瞬态频率偏差Transient frequency deviation100%突减功率100%Sudden reduce power%+124突加功率Sudden up power%-105频率恢复时间Frequency recovery timeS56相对的频率容差带Relative frequency tolerance zone%27稳态电压偏差Steady-state voltage deviation%2.58电压整定范围Setting of the voltage range%59瞬态电压偏差Transient voltage deviation100%突减功率100%
12、Sudden reduce power%+2510突加功率Sudden up power%-2011电压恢复时间Voltage recovery timeS612冷热态电压变化Cold and hot state voltage change%213电压不平衡度Voltage unbalance%57.机组配置Unit configuration机组柴油机采用潍柴WD10系列柴油机,配套无锡星诺电气有限公司生产的三相无刷交流发电机,柴油机和发电机通过弹性连接,安装在公共底盘上,机组控制屏采用侧屏式结构安装在公共底盘发电机侧的边梁上。WD385/8 diesel generating set i
13、s composed of Weichai WD10 series diesel engine, matching the three-phase Wuxi shine Electrical Company Limited production of brushless AC generator. Diesel engine and the generator connect through an elastic connecting, mounted on a common chassis, unit control panel adopts side screen structure mo
14、unted on a common chassis motor side beam.7.1 柴油机Diesel engine序号NO.项目Item参数reference1型号ModelWD10D204E102额定功率Rated power204kW3额定转速Rated speed1500r/min4启动方式Start methodDC24V电马达启动electrical start5型式Type水冷、直列、直喷Water-cooling,in-line,direct injection6进气方式Air intake method增压中冷Turbocharged intercooler7冲程St
15、roke48气缸数Cylinder numbers69气缸直径/行程Borestroke126/130mm10调速方式Speed control mode电子调速Electrical11停机方式Stop method电磁执行器Electromagnetic actuator12曲轴转向(面向输出端)Crankshaft steering(The output end)逆时针Anti-clockwise13机油牌号Oil gradeCD 15W/40 GB1112214燃油消耗率Fuel consumption ratio210g/kWh15机油消耗率Oil consumption ratio1
16、g /kWh7.2 发电机Alternator序号NO.项目Item参数reference1型号ModelXN274J2额定功率Rated power180kW3额定转速Rated speed1500r/min4额定频率Rated frequency50Hz5额定电压Rated voltage400V6额定功率因数Rated power factor0.8(滞后lag)7相数及接法Phase number and connection三相四线星形接法3phase4wire, Y connection8励磁方式Excitation type无刷Brushless9绝缘等级Insulation c
17、lassH10防护等级Protection gradeIP2111调压方式Voltage regulation mode自动Auto7.3控制屏Control panels7.3.1机组控制屏采用自动化发电机组控制器 和罗格朗TCL电动断路器,工作稳定可靠,能够对机组进行如下控制和操作:启动、怠速/额定转换、停机、紧急停机、蓄电池充电等。7.3.1 The unit control panel using automated generator controller TCL Electric and Legrand breaker, stable and reliable, able to c
18、ontrol and operate the unit as follows: Start, Idle / Rated conversion, shutdown, emergency shutdown, battery charging and so on.7.3.2 机组控制屏能够对机组如下参数进行测量并显示:三相电压、三相电流、功率、功率因数、频率、运行时间、柴油机的转速、润滑油压力、冷却水温度等。7.3.2 The unit control panel to set the following parameters can be measured and displayed: three
19、-phase voltage, phase current, power, power factor, frequency, run time, the engine speed, oil pressure, coolant temperature.7.3.3机组控制屏具有如下报警保护功能:7.3.3 alarm unit control panel has the following protection functions:7.3.4当机组电压高于机组额定电压的120%时,机组分闸停机,并报警;7.3.4 When the unit voltage is higher than 120%
20、of the rated voltage of the unit, the unit of the gate shut, and the police;7.3.5当机组电压低于机组额定电压的80%时,机组分闸,并报警;7.3.6 When the unit voltage is less than 80% of rated voltage of the unit, the unit of the gate, and the police;7.3.7 当机组电流超过机组额定电流的115%时,机组延时15秒分闸,并报警;7.3.7 When the unit current exceeds 115
21、% of rated current unit, the unit delay 15 seconds sub-gate, and the police;7.3.8当柴油机转速超过额定转速的110%时,报警;当柴油机转速超过额定转速的115%时,机组分闸停机,并报警;7.3.8 When the engine when the speed exceeds 110% of rated speed, alarm; when the engine speed exceeds 115% of rated speed, the crew of the gate shut, and the police;7
22、.3.9当柴油机润滑油压力低于0.12Mpa时,报警;当柴油机润滑油压力低于0.08Mpa时,机组分闸停机,并报警;7.3.9 When the engine when the oil pressure is lower than 0.12Mpa, alarm; when the engine oil pressure is less than 0.08Mpa, opening the unit shut down, and the police;7.3.10 当柴油机冷却水温高于95+3时,机组分闸,并报警;7.3.10 When the engine coolant temperature
23、 is higher than 95 +3 , the unit sub-gate, and the police;7.3.11当机组在自动状态时,若三次启动不成功,停止启动,并报警。7.3.11 When the unit is in automatic mode, if three unsuccessful start, stop, start, and alarm.8. 机组结构Structure柴油机和发电机之间采用弹片连接,通过减震器安装在公共底座上,水箱通过刚性连接直接安装在公共底盘上,控制屏采用侧立式结构安装在发电机侧面公共底盘上。The diesel engine and th
24、e generator is connected with shrapnel, mounted on a common base by the shock absorber, water tank through a rigid connection directly mounted on a common chassis, control panel adopts side vertical structure is installed in the generator side public chassis.9.供货范围Scope of supply序号NO.项目名称Item规格型号Spe
25、cifications数量Number单位Unit备注Remarks1柴油机Diesel engineWD10D204E101台Set装机Installed2发电机AlternatorXN274J1台Set装机Installed3控制屏Control panelP015000612021面Unit装机Installed4消音器Muffle6126001104961个Set散供Scattered offer5蓄电池Battery120Ah2块Block散供Scattered offer6蓄电池电缆Battery cableGR000003800011套Set散供Scattered offer7减震垫Shock padP000004800018块Block散供Scattered offe180kW柴油发电机组技术规格书 Technical Specification of 180kW Diesel Generating Set Page 11 of10