1、U N I T E D E L E C T R I C C O N T R O L SFEATURES Epoxy Coated Enclosure and Stainless Steel Component Parts Hermetically Sealed Snap Switch,SPDT or DPDT Output Terminal Block Wiring Adjustable Ranges:“WC ranges:300“wc vacuum to 250 “wc pressure(-747 to 623 mbar)Pressure:30“Hg Vac to 3500 psi (-1

2、to 241 bar)Differential pressure:0.8“wcd to 500 psid(2 mbar to 34.5 bar)Temperature:-120 to 640 F (-85 to 335 C)PRESSURE,VACUUM,DIFFERENTIAL PRESSURE,TEMPERATURE1 1 7-B-0 1117 Series117 Series2 U N I T E D E L E C T R I C C O N T R O L S 1 1 7-B-0 1117 Series1 1 7-B-0 1 U N I T E D E L E C T R I C C

3、 O N T R O LS 3117 SeriesApproved for Division 2 hazardous locations and corrosive atmospheres,the 117 Series can be used to measure vacuum,pressure,differential pressure or temperature in a variety of applications.Its compact,epoxy-coated enclosure and hermetically sealed snap switch provide superi

4、or corrosion resistance within the harshest environments.Popular sensors in a variety of materials are available,ranging from all welded stainless steel to elastomer diaphragms.Rugged,reliable and cost effective,the 117 Series is an ideal choice for the most demanding applications;typically wastewat

5、er treatment,pulp and paper mills,food and beverage plants,steel and aluminum mills and petrochemical and pharmaceutical plants.overviewfeatures Approved for Division 2 hazardous locations Epoxy-coated enclosure with captive cover screws Hermetically sealed snap switch,SPDT or DPDT output Terminal b

6、lock wiring Welded stainless steel diaphragms Ultra-low pressure ranges Flush mount sensors117 Series2 U N I T E D E L E C T R I C C O N T R O L S 1 1 7-B-0 1117 Series1 1 7-B-0 1 U N I T E D E L E C T R I C C O N T R O LS 3117 SeriesspecificationsSTORAGE TEMPERATURE -65 to 160F(-54 to 71C)AMBIENT T

7、EMPERATURE LIMITS -40 to 160F;except models 520-548,700-706:0 to 160F(-18 to 71C);set point typically shifts less than 1%of range for a 50F(28C)ambient temperature changeSET POINT REPEATABILITY Temperature models:1%of adjustable range Pressure models 171-174,218,358-376,520-535,540-543,560-564 and 7

8、00-706:1%of adjustable range;models 183-194,544-548,483-494,565-567:112%of adjustable range Internal set point lock on all pressure modelsSHOCK Set point repeats after 15 G,10 millisecond durationVIBRATION Set point repeats after 2.5 G,5-500 HzENCLOSURE Die cast aluminum(max.0.6%copper),epoxy powder

9、 coated;captive cover screwsENCLOSURE CLASSIFICATION Certified to Enclosure Type 4X requirementsSWITCH OUTPUT One SPDT hermetically sealed snap action switch;switch may be wired“normally open”or“normally closed”;DPDT(option 1190/1195)ELECTRICAL RATING 11 A 125/250 VAC resistive;5 A 28 VDC;1 A 48 VDC

10、;1/2 A 125 VDC;switch contacts gold flashedWEIGHT 112-612 lbs.Varies with modelELECTRICAL CONNECTION 1/2”NPT(female);two 7/8”diameter knockouts PRESSURE CONNECTION Models 218,358-376,700-706:1/4”NPT(female);models 171-194,483-494,520-535:1/2”NPT(female);models 560-564:2”sanitary connection;models 56

11、5-567:112”sanitary connection,models 540-548:1/8”NPT(female)TEMPERATURE ASSEMBLY Bulb and capillary:6 feet 304 stainless steel Immersion stem:nickel-plated brass(standard length only);optional 316L stainless steelFILL Non-toxic oil filledTEMPERATURE DEADBAND Typically 4%of range under laboratory con

12、ditions(70F ambient circulating bath at rate of 1/2F per minute change)REFERENCE SCALE Pressure:“Low-Medium-High”increment Temperature:calibrated dial scale4 U N I T E D E L E C T R I C C O N T R O L S 1 1 7-B-0 1117 Series117 Series1 1 7-B-0 1 U N I T E D E L E C T R I C C O N T R O LS 5117 Seriesa

13、pprovals pressure model chartBuna N diaphragm and O-ring and 1/2”NPT(female)epoxy coated aluminum pressure connection(Other wetted materials available-see page 9)520 300 Vac to 0 -746,7 to 0 0.8 to 32 2 to 79,6 200 13,8 400 27,6 521 10 Vac to 10 -24,9 to 24,9 0.4 to 2.4 1 to 5,9 200 13,8 400 27,6 52

14、2 50 Vac to 50 -124,5 to 124,5 0.4 to 12 1 to 29,8 200 13,8 400 27,6 523 0.5 to 5 1,2 to 12,4 0.4 to 1.2 1 to 3 200 13,8 400 27,6 524 2.5 to 50 6,2 to 124,5 0.4 to 3.2 1 to 7,9 200 13,8 400 27,6 525 10 to 250 24,9 to 622,3 0.4 to 24 1 to 59,7 200 13,8 400 27,6Welded 316L stainless steel diaphragm an

15、d 1/2”NPT(female)316L pressure connection 530 300 Vac to 0 -746,7 to 0 0.8 to 60 2 to 149,6 50 3,4 100 6,9 531 10 Vac to 10 -24,9 to 24,9 0.4 to 2.4 1 to 5,9 50 3,4 100 6,9 532 50 Vac to 50 -124,5 to 124,5 0.4 to 12 1 to 29,8 50 3,4 100 6,9 533 0.5 to 5 1,2 to 12,4 0.4 to 1.2 1 to 3 50 3,4 100 6,9 5

16、34 2.5 to 50 6,2 to 124,5 0.4 to 3.2 1 to 7,9 50 3,4 100 6,9 535 10 to 250 24,9 to 622,3 0.4 to 40 1 to 99,6 50 3,4 100 6,9*Over Range Pressure:The maximum pressure that may be applied continuously without causing damage and maintaining set point repeatability.*Proof Pressure:The maximum pressure to

17、 which a pressure sensor may be occasionally subjected,which causes no permanent damage.The unit may require calibration(e.g.start-up,testing).Model Adjustable Set Point Range Deadband *Over Range *Proof Pressure Low end of range on fall;Pressure High end of range on riseType H117 “wc mbar “wc mbar

18、psi bar psi bar UL listed,cUL certifiedPressure:UL 508,UL 1604,CSA C22.2 No.14-M91,CSA C22.2 No.213-1987Temperature:UL 508,UL 1604,CSA C22.2 No.24-M91,CSA C22.2 No.213-1987CE Compliance to Low Voltage Directive(LVD).CE Compliance to Pressure Equipment Directive(PED 97/23/EC).Compliance to NACE MR-01

19、75.(Standard on models 171-193,483-493)Class I,Division 2 Groups A,B,C,and D;Class II,Division 2 Group F,GClass IIIClass I,Zone 2,Group IIC4 U N I T E D E L E C T R I C C O N T R O L S 1 1 7-B-0 1117 Series117 Series1 1 7-B-0 1 U N I T E D E L E C T R I C C O N T R O LS 5117 SeriesWelded 316L stainl

20、ess steel diaphragm and pressure connection;2”sanitary connection.Mates with Tri-Clamp fitting systems or use with flush mount flanges(see page 9)560 0.5 to 15 0,03 to 1 0.3 to 3 0,03 to 0,2 200 13,8 300 20,7 561 1 to 25 0,07 to 1,7 0.3 to 4.5 0,03 to 0,3 200 13,8 300 20,7 562 2 to 50 0,14 to 3,4 0.

21、3 to 7.5 0,03 to 0,5 200 13,8 300 20,7 563 4 to 100 0,3 to 6,9 0.3 to 12 0,03 to 0,8 200 13,8 300 20,7 564 8 to 200 0,6 to 13,8 0.3 to 15 0,03 to 1 200 13,8 300 20,7Welded 316L stainless steel diaphragm and pressure connection;1 1 2”sanitary connection.Mates with Tri-Clamp fitting systems or use wit

22、h flush mount flanges(see page 9)565 5 to 30 0,3 to 2,1 3 to 15 0,21 to 1 1000 68,9 1500 103,4 566 10 to 100 0,7 to 6,9 3 to 36 0,21 to 2,5 1000 68,9 1500 103,4 567 15 to 300 1 to 20,7 9 to 66 0,63 to 4,6 1000 68,9 1500 103,4Welded 316L stainless steel diaphragm and 1/2”NPT(female)316L pressure conn

23、ection,large 0.72”orifice for clean-out purposes 171 1 to 20 0,07 to 1,4 0.1 to 3 0,007 to 0,2 500 34,5 1000 68,9 172 2 to 50 0,14 to 3,4 0.1 to 5 0,007 to 0,3 500 34,5 1000 68,9 173 4 to 100 0,3 to 6,9 0.1 to 10 0,007 to 0,7 500 34,5 1000 68,9 174 8 to 200 0,6 to 13,8 0.1 to 15 0,007 to 1 500 34,5

24、1000 68,9316L stainless steel diaphragm(optional Hastelloy C,Monel or Tantalum);Viton GLT O-ring(optional Kalrez,Silicone,Ethylene Propylene,or Aflas);316 stainless steel 1/2”NPT(female)pressure connection(optional Hastelloy B or C,or Monel),large 0.72”orifice for clean-out purposes.Models 188 and 1

25、89,316L stainless steel pressure connection.183 1 to 20 0,07 to 1,4 0.3 to 5 0,021 to 0,3 500 34,5 1000 68,9 184 2 to 50 0,14 to 3,4 0.3 to 6 0,021 to 0,4 500 34,5 1000 68,9 185 4 to 100 0,3 to 6,9 0.5 to 10 0,03 to 0,7 500 34,5 1000 68,9 186 8 to 200 0,6 to 13,8 0.5 to 17 0,03 to 1,2 500 34,5 1000

26、68,9 188 50 to 1000 3,4 to 68,9 30 to 300 2,07 to 20,7 2000 137,9 7000 482,6 189 250 to 3500 17,3 to 241,3 50 to 500 3,45 to 34,5 4000 275,8 7000 482,6316L stainless steel diaphragm(optional Hastelloy C,Monel or Tantalum);Viton GLT O-ring(optional Kalrez,Silicone,ethylene propylene or Aflas);316 sta

27、inless steel 1/2”NPT(female)pressure connection(optional Hastelloy B or C,or Monel),0.06”orifice to dampen pulsations.Models 488 and 489,316L stainless steel pressure connection 483 1 to 20 0,07 to 1,4 0.3 to 5 0,021 to 0,3 500 34,5 1000 68,9 484 2 to 50 0,14 to 3,4 0.3 to 6 0,021 to 0,4 500 34,5 10

28、00 68,9 485 4 to 100 0,3 to 6,9 0.5 to 10 0,03 to 0,7 500 34,5 1000 68,9 486 8 to 200 0,6 to 13,8 0.5 to 17 0,03 to 1,2 500 34,5 1000 68,9 488 50 to 1000 3,4 to 68,9 30 to 300 2,07 to 20,7 2000 137,9 7000 482,6 489 250 to 3500 17,3 to 241,3 50 to 500 3,45 to 34,5 4000 275,8 7000 482,6Application Not

29、e:The use of metallic diaphragms where higher pressure shock or heavy cycling is expected should be avoided.Models 171-174 should not be used where system or start-up vacuum pressure might exceed 26”Hg Vac(-0,9 bar).Use of optional diaphragm materials for models 483-489 may increase deadband.Hastell

30、oy is a registered trademark of Haynes International,Inc.Monel is a registered trademark of the INCO family of companiesKalrez is a registered trademark of E.I.Dupont Aflas is a registered trademark of Asahi GlassViton is a registered trademark of E.I.DuPontTri-Clamp is a registered trademark of Tri

31、-Clover,Inc.Model Adjustable Set Point Range Deadband *Over Range*Proof Pressure Low end of range on fall;Pressure High end of range on riseType H117 psi bar psi bar psi bar psi bar 6 U N I T E D E L E C T R I C C O N T R O L S 1 1 7-B-0 1117 Series117 Series1 1 7-B-0 1 U N I T E D E L E C T R I C C

32、 O N T R O LS 7117 Series Phosphor bronze bellows and nickel-plated brass 1/4”NPT(female)pressure connection;303 stainless steel spring exposed to media 218 30“Hg Vac to 0-1 to 0 2 to 5“Hg 0,07 to 0,17 0 0 30 2,1 316L stainless steel bellows and 1/4”NPT(female)pressure connection 358 15 to 200 1 to

33、13,8 6 to 20 0,4 to 1,4 200 13,8 800 55,2 361 20 to 300 1,4 to 20,7 8 to 22 0,6 to 1,5 300 20,7 800 55,2 376 25 to 500 1,7 to 34,5 10 to 28 0,7 to 1,9 500 34,5 800 55,2 Welded 316 stainless steel diaphragm and 1/2”NPT(female)pressure connection,large 0.72”orifice for clean-out purposes 190 5 to 30 0

34、,3 to 2,1 3 to 8 10 max 0,2 to 0,6 1500 103,4 2500 172,4 191 10 to 100 0,7 to 6,9 3 to 30 45 max 0,2 to 2,1 1500 103,4 2500 172,4 192 15 to 300 1 to 20,7 10 to 40 60 max 0,7 to 2,7 1500 103,4 2500 172,4 193 20 to 500 1,4 to 34,5 15 to 45 75 max 1 to 3,1 1500 103,4 2500 172,4 194 80 to 1700 5,5 to 11

35、7,2 5 to 120 200 max 0,3 to 8,3 2000 137,9 2500 172,4 Welded 316 stainless steel diaphragm and 1/2”NPT(female)pressure connection,0.06”orifice to dampen pulsations 490 5 to 30 0,3 to 2,1 3 to 8 10 max 0,2 to 0,6 1500 103,4 2500 172,4 491 10 to 100 0,7 to 6,9 3 to 30 45 max 0,2 to 2,1 1500 103,4 2500

36、 172,4 492 15 to 300 1 to 20,7 10 to 40 60 max 0,7 to 2,7 1500 103,4 2500 172,4 493 20 to 500 1,4 to 34,5 15 to 45 75 max 1 to 3,1 1500 103,4 2500 172,4 494 80 to 1700 5,5 to 117,2 5 to 120 200 max 0,3 to 8,3 2000 137,9 2500 172,4pressure model chartDeadband Notes:Models 190-194,490-494 are expresse

37、d as the lower 75%and top 25%of the range span because of the operating characteristics of the welded stainless steel diaphragm sensor.*Over Range Pressure:The maximum pressure that may be applied continuously without causing damage and maintaining set point repeatability.*Proof Pressure:The maximum

38、 pressure to which a pressure sensor may be occasionally subjected,which causes no permanent damage.The unit may require calibration(e.g.start-up,testing).*Working Pressure Range:The pressure range within which two opposing sensors can be safely operated and still maintain set point adjustability pr

39、ovided the difference in pressure between them does not exceed the designated adjustable range.Model Adjustable Set Point Range Deadband *Over Range *Proof PressureType H117 psi(unless noted)bar psi(unless noted)bar psi bar psi bar Lower 75%Top 25%Lower 75%range span range span range span psi(unless

40、 noted)psi bar 6 U N I T E D E L E C T R I C C O N T R O L S 1 1 7-B-0 1117 Series117 Series1 1 7-B-0 1 U N I T E D E L E C T R I C C O N T R O LS 7117 Series Buna N diaphragm and O-ring with 303 stainless steel 1/4”NPT(female)pressure connection;option M540 Viton diaphragm and O-ring available 700

41、3 to 20 0,2 to 1,4 1 to 4 0,07 to 0,3 500 34,5 1000 68,9 702 3 to 100 0,2 to 6,9 2 to 12 0,14 to 0,8 500 34,5 1000 68,9 704 15 to 500 1 to 34,5 15 to 30 1,03 to 2,1 1500 103,4 2500 172,4 706 100 to 1700 6,9 to 117,2 20 to 110 1,38 to 7,6 2000 137,9 2500 172,4DIFFERENTIAL PRESSURE MODEL CHART Kapton

42、diaphragm,Buna N sealing diaphragms and epoxy coated aluminum 1/8”NPT(female)pressure connections 540 0.8 to 7“wcd 2 to 17,4 mbar 0.1 to 1.3“wc 0,2 to 3,2 mbar 200 13,8 400 27,6 541 2 to 20“wcd 5 to 49,7 mbar 0.2 to 1.6“wc 0.5 to 4,0 mbar 200 13,8 400 27,6 542 5 to 50“wcd 12,4 to 124,4 mbar 0.4 to 4

43、.0“wc 1,0 to 10,0 mbar 200 13,8 400 27,6 543 10 to 200“wcd 24,9 to 497,0 mbar 0.8 to 12“wc 2,0 to 29,9 mbar 200 13,8 400 27,6 544 2 to 20 0,1 to 1,4 bar 0.2 to 2 0,0 to 0,1 bar 1200 82,7 2500 172,4 545 5 to 50 0,3 to 3,4 bar 0.4 to 3.2 0 to 0,1 bar 1200 82,7 2500 172,4 546 10 to 125 0,7 to 8,6 bar 0

44、.7 to 7.0 0,0 to 0,2 bar 1200 82,7 2500 172,4 547 50 to 250 3,4 to 17,2 bar 1.0 to 15.0 0,1 to 1,0 bar 1200 82,7 2500 172,4 548 100 to 500 6,9 to 34,5 bar 2.0 to 20.0 0,1 to 1,4 bar 1200 82,7 2500 172,4TEMPERATURE MODEL CHART 120 0 to 225 -17.8 to 107.2 275 135 10 5 9/16”x 1 7 8”below 1/2”NPT thread

45、(nickel-plated brass)121 200 to 425 93.3 to 218.3 475 246.1 10 5 9/16”x 1 7 8”below 1/2”NPT thread(nickel-plated brass)Type E117 Bulb OD x length 2BSA -120 to 100 -84.4 to 37.8 150 65.5 10 5 3/8 x 2 5 8”5BS -20 to 80 -28.9 to 26.7 130 54.4 5 2 3/8 x 5”4BS 25 to 100 -3.9 to 37.8 150 65.5 2 1 3/8 x 6

46、3 4”2BSB 30 to 250 -1.1 to 121.1 300 148.9 10 5 3/8 x 2 5 8”3BS 100 to 400 37.8 to 204.4 450 232.2 10 5 3/8 x 2 1 8”8BS 350 to 640 176.7 to 337.8 690 365.6 10 5 3/8 x 3 1 4”Kapton is a registered trademark of E.I.DuPont.Optional immersion stem lengths and capillary lengths are available.Model Adjust

47、able Set Point Range Deadband *Over Range Pressure *Proof Pressure Lower end of range on fall;High end of range on rise Type H117 psi bar psi bar psi bar psi bar Model Adjustable Set Point Range Deadband *Working *Proof Pressure Pressure Type H117K psid(unless noted)bar psi(unless noted)bar psi bar

48、psi bar Model Adjustable Range Max.Temp Scale Stem/Bulb Division SizeType B117 F C F C F C OD x Length 8 U N I T E D E L E C T R I C C O N T R O L S 1 1 7-B-0 1117 Series117 Series1 1 7-B-0 1 U N I T E D E L E C T R I C C O N T R O LS 9117 Serieshow to orderBUILDING A PART NUMBERSelect a Type Select

49、 a Model Select an OptionRefer to the“Type”section below.Determine type number based on switch output,enclosure,adjustment and reference.Refer to the“Model Charts”Determine model based on adjustable range,deadband and proof pressure.Fill in the model portion of your part number with the correspondin

50、g number.Refer to the“Options”section Determine option number based on switch output,optional materials or other product enhancements.Fill in the option portion of your part number with the corresponding number.Leave“option”portion blank if no options are needed.FOR MULTIPLE OPTIONS:Call United Elec