《混凝土筒仓仓壁及漏斗计算.xls》由会员分享,可在线阅读,更多相关《混凝土筒仓仓壁及漏斗计算.xls(39页珍藏版)》请在taowenge.com淘文阁网|工程机械CAD图纸|机械工程制图|CAD装配图下载|SolidWorks_CaTia_CAD_UG_PROE_设计图分享下载上搜索。
1、名称密度内摩擦角摩擦系数外摩擦角(KN/m)()混凝土钢板()稻谷6350.50.3526.57大米8.5300.420.322.78玉米7.8280.420.3222.78小麦8250.40.321.8大豆7.5250.40.321.8葵花籽5.5300.40.3面粉6.5400.30.321.8麸皮4400.30.3大麦6.5270.40.4豆粕6.5350.50.35稻壳1.8350.50.35屋面荷载计算屋面恒载:G表层卷材0.05KN/m2防水卷材0.1KN/m220厚砂浆找平0.4KN/m235厚硬质聚氨酯泡沫塑料0.02KN/m2预制大型屋面板及灌缝1.5KN/m2屋面支撑0.1
2、KN/m2合计:2.07KN/m2屋面活载:Q活0.5KN/m2基本雪压:Q雪0.4KN/m2屋架选用可变荷载控制:1.2xG+1.4xQ=3.18KN/m2 永久荷载控制:1.35xG+1.4x0.7xQ=3.28KN/m2屋架选用图集04G415-1,屋架型号为YWJ21-1Ba及YWJ24-1Ba屋面板选用屋面恒载不包括屋面板及灌缝 G=0.57KN/m2屋面活载标准值 Q=0.5KN/m2荷载设计值:1.2xG+1.4xQ=1.38KN/m21.35xG+1.4x0.7xQ=1.26KN/m2 屋面板选用图集04G41-1:屋面板型号为Y-WB-2 允许外加荷载=2.05KN/m2 天
3、沟板选用图集04G41-2:天沟板采用TGB77 允许外加荷载=4.26KN/m平房仓贮料压力及墙体计算贮料信息贮料名称玉米贮料压力计算公式:贮料密度=7.8KN/m内摩擦角=28.0外摩擦角=22.8侧压力系数k(用于水平压力计算取0)0.3190(0)0.3610(0)贮料高度h=7.00m檐墙柱距S1=5.00m储料荷载计算贮料标高(m)hi=0.0001.1002.3003.4004.8007.0007.000储粮深度(m)Si=7.0005.9004.7003.6002.2000.0000.000水平压力(kN/m2)Ph,i=19.71216.61513.23510.1386.19
4、50.0000.000竖向摩擦力(kN/m2)Pf,i=7.3146.1654.9113.7622.2990.0000.000垂直压力(kN/m2)Pv,i=54.60046.02036.66028.08017.1600.0000.000圈梁水平力(kN/m)Pl,i=10.41619.02615.30212.40810.1381.7040.000对柱水平力(kN/m)Qi=52.0895.1376.5162.0450.698.520.00墙体承载力计算抗弯强度设计值ftm=0.12MPa抗剪强度设计值 fv=0.12MPa设计信息墙体厚度(mm)hw370370370370370370截面抵
5、抗矩(m/m)Wbhw2/60.02280.02280.02280.02280.02280.0228内力臂(m)Z=2hw/30.24670.24670.24670.24670.24670.2467圈梁高度(m)bi+10.250.250.250.250.250梁间净跨(m)li0.850.950.851.151.9499990.000001分项系数1.31.31.31.31.31.3梯形荷载(kN)q1=Pi+117.3213.9410.846.900.700.00q2=Pi19.7116.6113.2410.146.200.00计算系数=q1/q20.8790.8390.8190.6810
6、.1140.0000.9400.9210.9110.8450.6130.577抗弯验算(kNm)1.671.721.091.411.670.00设计值M=Mk2.172.241.411.832.170.00容许值M=ftmW2.7382.7382.7382.7382.7382.738验算结果满足满足满足满足满足满足抗剪验算(kNm)8.047.475.295.214.260.00设计值V=Vk10.459.716.876.775.530.00容许值V=fvbZ29.629.629.629.629.629.6验算结果满足满足满足满足满足满足贮料对柱总摩擦力118.0kN 23.60363檐墙对柱
7、轴力 0.37*10.1*19*5.6397.6kN12 Ssinkh21f23221612vlqMk1312vlqqVk212612cossin)sin(1coscos2kkrsPhtankrsPfrsPv)0(sin1sin1)245(tan2k檐墙柱基础设计(独立基础)基础设计参数基础参数边长 X12.5m X22mX=4.5m Y=3m埋深 Z=2.5m高度 H=0.7m基础及土平均重度 土20kN/m地下水深度d=5m檐墙柱截面宽 b10.4m截面高h10.9mPK传递柱底内力(弯矩最大同时也是抗滑移剪力最不利)柱底内力标准组合基本组合代号轴力最大弯矩最大代号轴力最大弯矩最大轴力(k
8、N)Nck84.2932.55Nc110.0837.64弯矩(kNm)Mck1.82868.05Mc5.311207.41剪力(kN)Vck28.66415.16Vc37.41578.51贮料荷载(标准值):贮料自重183.1 kN偏心距-1.475 m自重弯矩-270.04 kNm基础及基础以上土重度:G土=XYZ土=675.0kN地下水浮力F水=0.0kN修正后基底土承载力Fa=316.0kPa 基础设计标准值代号轴力最大弯矩最大计算公式轴力(kN)Nk267.4215.6弯矩(kNm)Mk-269.2880.5平均反力(kN/m)P19.816.0 P=Nk/A偏心距(m)e-0.290
9、.99 e=Mk/(Nk+Gk)X/6 X/6X/6=0.75m最大反力1(kN/m)Pmax143.2152.9最小反力1(kN/m)Pmin196.4-21.0最大反力2(kN/m)Pmax282.6156.9最小反力2(kN/m)Pmin20.00.0最大反力(kN/m)Pmax156.9eX/6 取Pmax1 否则取 Pmax2最小反力(kN/m)Pmin0.0eX/6 取 Pmin1 否则取 Pmin2地基承载力验算Pmax156.9kN/mFa,通过 基础设计组合值代号轴力最大弯矩最大计算公式轴力(kN)N348.1275.6弯矩(kNm)M-345.7856.4 抗滑移验算:基底
10、摩擦系数=0.5抗滑移稳定系数 k=1.3轴力:194.1kN(Nck取弯矩最大标准组合值)剪力:415.2kN(Vck取弯矩最大标准组合值)334.3kN V,不满足基础倾角=6Gn=869.0662 kN1.409284贮G3.1cNN贮MMMc3.1ckVV0.1贮GN9.0ckNk)FG(NH水土1122/SYfhXhY G贮2X2X21=e22h贮贮贮贮eGM贮GNckkN)5.0(2xxNHVMMMckckckk贮21min1max6YXMXYGNPPkk土0)5.0322min2maxPeXYGNPk(土山墙柱设计计算山墙柱顶高 H1=10.5m地面以下柱高 H01m山墙柱总高H
11、=H0+H1=11.5m混凝土容重 c25kN/m山墙柱截面宽 b20.4m山墙柱截面高 h20.8m檐墙柱距S1=5.0m山墙柱距S2=4.8m山墙厚度B2=0.37m墙体容重w19kN/m屋面恒载FG=2.1kN/m2屋面活载FQ=0.5kN/m2山墙风压0=0.45kN/m2地圈梁高hL0=0.5m风压对柱荷载标准值p=1.08kN/ma=10.5mb=1mM风=17.36kNmV风=6.69kN贮料对柱底弯矩标准值荷载P1P2P3P4P5P6P7Pi50.0091.3273.4559.5648.668.180.00a10.59.48.27.15.73.5000013.5b12.13.3
12、4.45.87.9999998Mi43.66142.45148.03130.84104.6112.990.00Vi49.4587.0365.2448.1533.223.620.00合计582.6 kNm286.71 kN柱自重 G柱=cb2H=115.0kN 山墙自重 G墙w(S2-b2)B2H1+cB2hL0 328.5kN 屋面恒载 G屋FGS1S2/2=25.2kN 屋面活载 Q屋0.5FQS1S2 6.0kN 山墙柱内力设计值(配筋)墙体传递给柱压力折算系数 =1.00柱底轴力设计值N=G柱+(G屋+G墙)468.69 kN(有利荷载,分享系数取1.0)柱底弯矩设计值M1.3Mp+0.
13、6M风=767.78 kNm柱底剪力设计值V=1.3Vp+0.6V风=376.73 kNniiPMM1niiPVV1山墙柱基础设计(独立基础)基础设计参数基础参数边长 X11.6m X21mX=2.6m Y=2.4m埋深 Z=1.5m基础及土平均重度 土20kN/m地下水深度d=5m 柱自重(标准值)自重 G柱115kN偏心距-0.3m附加弯矩-34.5kNm山墙荷载(标准值):(墙体全部传至独立基础)自重 G墙328.5kN偏心距-0.52m附加弯矩M墙=G墙e墙-169.2kNm贮料荷载(标准值):柱底水平弯矩Mp582.59kNm柱底水平剪力Vp=286.71kN剪力附加弯矩143.35
14、kNm贮料自重78.624kN偏心距-1m自重弯矩-78.62kNm贮料弯矩合计647.32kNm屋面荷载(标准值):恒载:G屋=0.5FGS1S225.20kN活载:Q屋=0.5FGS1S26kN偏心距e屋-0.52m恒载弯矩:M屋G=G屋e屋=-12.98kNm活载弯矩:M屋Q=Q屋e屋=-3.09kNm风荷载(标准值):柱底水平弯矩M风17.36kNm柱底水平剪力V风=6.69kN剪力附加弯矩3.34kNm风荷弯矩合计20.70kNm基础及基础以上土重度:G土=XYZ土=187.2kN地下水浮力F水=0kN 基础设计标准值轴力:547.3kN弯矩:#280 kN/m偏心距:e=Mk/(N
15、k+G土)=0.60m X 60.43m291 kN/m取Pmax291kN/mFa,通过 基础设计组合值(配筋采用理正工具箱计算)轴力:668.8kN弯矩:635.12 kNm 抗滑移验算:基底摩擦系数=0.5抗滑移稳定系数k=1.3轴力:492.6kN剪力:290.7kN261.5kNV,不满足 2XX=e2柱2X21X=e222Bh墙柱柱柱eGM2/22hXhY G贮2X2X21=e22h贮贮贮贮eGM 0HZVMpv贮贮MMMMvp0HZVMv风风vMMM风风风屋柱屋墙柱QNkGGGG风屋屋贮墙柱MMMMMMMQk6.0G屋贮屋墙柱QN7.0G3.1)GGG(2.1风屋贮屋墙柱MMMM
16、MMMQ6.07.03.10.1G)5.0322maxeXYGNPk(土21max6YXMXYGNPkk土风QVVp6.00.1贮屋墙柱GGGG9.0Nk)FG(NH水土敖间墙柱设计计算敖间柱高 H1=10.5m地面以下柱高 H01m敖间柱总高H=H0+H1=11.5m混凝土容重 c25kN/m敖间柱截面宽 b30.4m敖间柱截面高 h30.49m檐墙柱距S1=5.0m敖间柱距S3=2.7m敖间墙厚度B3=0.49m墙体容重w19.00kN/m屋面恒载FG=2.1kN/m2屋面活载FQ=0.5kN/m2地圈梁高hL0=0.5m贮料对柱底弯矩标准值荷载P1P2P3P4P5P6P7Pi28.125
17、1.3741.3133.5027.374.600.00a10.59.48.27.15.73.5000013.5b12.13.34.45.87.9999998Mi24.5680.1383.2773.6058.857.300.00Vi27.8148.9636.7027.0818.682.040.00合计327.7 kNm161.27 kN柱自重 G柱=cb2H=115.0kN 山墙自重 G墙w(S2-b2)B2H1+cB2hL0 229.8kN 屋面恒载 G屋FGS1S2=28.4kN 屋面活载 Q屋FQS1S2 6.8kN 敖间墙柱内力设计值(配筋)墙体传递给柱压力折算系数 =1柱底轴力设计值N
18、=Nc+(Nm+Nw)373.19 kN柱底弯矩设计值M1.3Mp=426.02 kNm柱底剪力设计值V=1.3Vp=209.66 kNniiPVV1niiPMM1敖间墙柱基础设计(独立基础)基础设计参数基础参数边长 X3.2m Y=1m埋深 Z=1.5m基础及土平均重度 土20kN/m地下水深度d=5m柱自重(标准值)自重 G柱115kN山墙荷载(标准值):(墙体全部传至独立基础)自重 G墙229.8kN单侧贮料荷载(标准值):柱底水平弯矩Mp327.70kNm柱底水平剪力Vp=161.27kN剪力附加弯矩80.64kNm贮料自重73.983kN偏心距-0.92m自重弯矩-68.25kNm贮
19、料弯矩合计340.09kNm屋面荷载(标准值):恒载:G屋=FGS1S328.35kN活载:Q屋=FGS1S36.75kN基础及基础以上土重度:G土=XYZ土=96kN地下水浮力F水=0kN 基础设计标准值(地基承载力验算)单侧堆载情况:轴力:453.9kN弯矩:#371 kN/m偏心距:e=Mk/(Nk+G土)=0.62m X 60.53m374 kN/m取Pmax374kN/mFa,不通过两侧堆载情况:轴力:527.9kN基底反力:165.0kN/mFa,通过 基础设计组合值(配筋采用理正工具箱计算)单侧堆载情况:轴力:548.7 kN弯矩:442.12 kNm两侧堆载情况:轴力:644.
20、9kN 抗滑移验算:基底摩擦系数=0.5抗滑移稳定系数k=1.3轴力:402.5kN剪力:161.27 kN191.7kNV ,满足2/3hXhY G贮3X41=eh贮贮贮贮eGM 0HZVMpv贮贮MMMMvp屋贮屋墙柱QNkGGGGmkMMdQN7.0G3.1)GGG(2.1mdwcmMM3.1pVV0.1屋贮屋墙柱QNkG2GGGXYNPkmax21max6YXMXYGNPkk土)5.0322maxeXYGNPk(土k)FG(NH水土贮屋墙柱GGGG9.0N屋贮屋墙柱QN7.0G23.1)GGG(2.1伸缩缝山墙柱设计计算山墙柱顶高 H1=10.5m地面以下柱高 H01m山墙柱总高H=H
21、0+H1=11.5m混凝土容重 c25kN/m山墙柱截面宽 b20.4m山墙柱截面高 h20.8m檐墙柱距S1=5.0m山墙柱距S2=4.8m山墙厚度B2=0.37m墙体容重w19kN/m屋面恒载FG=2.1kN/m2屋面活载FQ=0.5kN/m2地圈梁高hL0=0.5m贮料对柱底弯矩标准值荷载P1P2P3P4P5P6P7Pi50.0091.3273.4559.5648.668.180.00a10.59.48.27.15.73.5000013.5b12.13.34.45.87.9999998Mi43.66142.45148.03130.84104.6112.990.00Vi49.4587.03
22、65.2448.1533.223.620.00合计582.6 kNm286.71 kN柱自重 G柱=cb2H=115.0kN(单柱)山墙自重 G墙(w(S2-b2)B2H1+cB2hL0)328.5kN(单片)屋面恒载 G屋0.5FGS1S2=25.2kN(单侧)屋面活载 Q屋0.5FQS1S2 6.0kN(单侧)伸缩缝山墙柱内力设计值(配筋)墙体传递给柱压力折算系数 =1.00柱底轴力设计值N=G柱+(G屋+G墙)146.20 kN(有利荷载,分享系数取1.0)柱底弯矩设计值M1.3Mp=757.36 kNm柱底剪力设计值V=1.3Vp372.72 kNniiPMM1niiPVV1伸缩缝山墙
23、柱基础设计(独立基础)基础设计参数基础参数边长 X3.6m Y=2.4m伸缩缝间距 s=0.48m埋深 Z=1.5m基础及土平均重度 土20kN/m地下水深度d=5m 柱自重(标准值)双柱自重 G柱 230.0kN 山墙荷载(标准值):(墙体全部传至独立基础)双片自重 G墙 657.0kN 屋面荷载(标准值):双侧恒载:G屋=50.4kN 双侧活载:Q屋=12.0kN 单侧贮料荷载(标准值):柱底水平弯矩Mp582.6kNm柱底水平剪力Vp=286.7kN剪力附加弯矩143.4kNm贮料自重155.9kN偏心距-1.205m自重弯矩-187.9kNm贮料弯矩合计538.0kNm基础及基础以上土
24、重度:G土=XYZ土=259.2kN地下水浮力F水=0.0kN 基础设计标准值(地基承载力验算)单侧堆载情况:轴力:1105.3kN弯矩:#262 kN/m偏心距:e=Mk/(Nk+G土)=0.39m X 60.60m270 kN/m取Pmax262kN/mFa,通过两侧堆载情况:轴力:1261.2kN基底反力:146.0kN/mFa,通过 基础设计组合值(配筋采用理正工具箱计算)单侧堆载情况:轴力:1336.0kN弯矩:699.45 kNm两侧堆载情况:轴力:1538.7kN 抗滑移验算:基底摩擦系数=0.5抗滑移稳定系数k=1.3轴力:984.0kN剪力:286.7kN478.1kNV ,
25、满足2/22sBXhY G贮贮贮贮eGM 0HZVMpv贮贮MMMMvp屋贮屋墙柱QN7.0G3.1)GGG(2.1贮MM3.1pVV0.1贮屋墙柱GGGG9.0Nk)FG(NH水土sB22X41=e贮屋贮屋墙柱QNkGGGGmkMM21max6YXMXYGNPkk土)5.0322maxeXYGNPk(土屋贮屋墙柱QNkG2GGGXYNPkmax屋贮屋墙柱QN7.0G23.1)GGG(2.1平房仓贮料压力及墙体计算贮料信息贮料名称小麦贮料压力计算公式:贮料密度=8KN/m内摩擦角=25.0外摩擦角=21.8侧压力系数k(用于水平压力计算时=0)k0=0.3562(0)k=0.4059(=0)(
26、计算基础可考虑 0)贮料高度h=5.30m檐墙柱距S1=10.60m储料荷载计算贮料标高(m)hi=0.0000.8001.7002.6003.6005.3005.300储粮深度(m)Si=5.3004.5003.6002.7001.7000.0000.000水平压力(kN/m2)Ph,i=17.20814.61111.6898.7675.5200.0000.000竖向摩擦力(kN/m2)Pf,i=6.0405.1284.1033.0771.9370.0000.000垂直压力(kN/m2)Pv,i=42.40036.00028.80021.60013.6000.0010.000圈梁水平力(kN
27、/m)Pl,i=6.53712.32710.5208.2256.4291.5640.000对柱水平力(kN/m)Qi=69.29130.67111.5187.1968.1416.580.00墙体承载力计算抗弯强度设计值ftm=5.30MPa抗剪强度设计值 fv=0.12MPa设计信息墙体厚度(mm)hw240240240240240240截面抵抗矩(m/m)Wbhw2/60.00960.00960.00960.00960.00960.0096内力臂(m)Z=2hw/30.16000.16000.16000.16000.16000.1600圈梁高度(m)bi+10.250.250.250.250
28、.250梁间净跨(m)li0.550.650.650.751.44991E-04分项系数1.31.31.31.31.31.3梯形荷载(kN)q1=Pi+115.4212.509.586.330.810.00q2=Pi17.2114.6111.698.775.520.00计算系数=q1/q20.8960.8560.8190.7220.1470.0000.9490.9290.9110.8650.6240.577抗弯验算(kNm)0.620.720.560.530.840.00设计值M=Mk0.800.930.730.691.100.00容许值M=ftmW50.87950.87950.87950.8
29、7950.87950.879验算结果满足满足满足满足满足满足抗剪验算(kNm)4.574.523.572.982.860.00设计值V=Vk5.945.884.643.883.720.00容许值V=fvbZ19.219.219.219.219.219.2验算结果满足满足满足满足满足满足贮料对柱总摩擦力157.5kN檐墙对柱轴力 0.37x10.1x19x5.6397.6kN12 Ssinkh21f23221612vlqMk1312vlqqVk212612cossin)sin(1coscos2kkrsPhtankrsPfrsPv)0(sin1sin1)245(tan2k檐墙柱基础设计(独立基础)
30、基础设计参数基础参数边长 X12.2m X21mX=3.2m Y=2.4m埋深 Z=2m基础根部高度 H=0.5m基础及土平均重度 土20kN/m地下水深度d=2m檐墙柱截面宽 b10.4m截面高h10.8mPK传递柱底内力(按 0的粮食荷载下PK计算结果,弯矩最大同时也是抗滑移剪力最不利)柱底内力标准组合基本组合代号轴力最大弯矩最大代号轴力最大弯矩最大轴力(kN)Nck894.78729.38Nc1130.38738弯矩(kNm)Mck1096.721213.24Mc1017.371657.14剪力(kN)Vck449.6458.51Vc429.03615.89贮料荷载(标准值):贮料自重6
31、1.1kN偏心距-1.3 m自重弯矩-79.37 kNm基础及基础以上土重度:G土=XYZ土=307.2kN地下水浮力F水=0.0kN修正后基底土承载力Fa=190.0kPa 基础设计标准值代号轴力最大弯矩最大计算公式轴力(kN)Nk955.8790.4弯矩(kNm)Mk705.3925.5平均反力(kN/m)P124.5102.9 P=Nk/A偏心距(m)e0.560.84 e=Mk/(Nk+Gk)X/6 X/6X/6=0.53m最大反力1(kN/m)Pmax1336.6368.9最小反力1(kN/m)Pmin1-7.7-83.0最大反力2(kN/m)Pmax2336.8402.9最小反力2
32、(kN/m)Pmin20.00.0最大反力(kN/m)Pmax402.9eX/6 取Pmax1 否则取 Pmax2最小反力(kN/m)Pmin0.0eX/6 取 Pmin1 否则取 Pmin2地基承载力验算Pmax402.9kN/m1.2Fa,不通过 基础设计组合值代号轴力最大弯矩最大计算公式轴力(kN)N1209.8817.4弯矩(kNm)M914.21554.0 抗滑移验算:基底摩擦系数=0.4抗滑移稳定系数 k=1.3轴力:711.4kN(Nck取弯矩最大标准组合值)剪力:458.5kN(Vck取弯矩最大标准组合值)313.4kNV,不满足贮G3.1cNN贮MMMc3.1ckVV0.1贮
33、GN9.0ckNk)FG(NH水土2/12hXhY G贮2X2X21=e22h贮贮贮贮eGM贮GNckkN)5.0(2xxNHVMMMckckckk贮21min1max6YXMXYGNPPkk土0)5.0322min2maxPeXYGNPk(土山墙柱设计计算山墙柱顶高 H1=10.5m地面以下柱高 H01m山墙柱总高H=H0+H1=11.5m混凝土容重 c25kN/m山墙柱截面宽 b20.4m山墙柱截面高 h20.8m檐墙柱距S1=10.6m山墙柱距S2=4.8m山墙厚度B2=0.37m墙体容重w19kN/m屋面恒载FG=2.1kN/m2屋面活载FQ=0.5kN/m2山墙风压0=0.45kN/
34、m2地圈梁高hL0=0.5m风压对柱荷载标准值p=1.08kN/ma=10.5mb=1mM风=17.36kNmV风=6.69kN贮料摩擦力 71.3kN贮料对柱底弯矩标准值荷载P1P2P3P4P5P6P7Pi31.3859.1750.5039.4830.867.510.00a10.59.78.87.96.95.20015.2b11.82.73.64.66.29996.3Mi27.4082.8192.0882.3668.1315.530.00Vi31.0357.1146.6534.2824.444.740.00合计368.3 kNm198.26 kN柱自重 G柱=cb2H=115.0kN 山墙自
35、重 G墙w(S2-b2)B2H1+cB2hL0 328.5kN 屋面恒载 G屋FGS1S2/2=53.4kN 屋面活载 Q屋0.5FQS1S2 12.7kN 山墙柱内力设计值(配筋)墙体传递给柱压力折算系数 =1.00柱底轴力设计值N=G柱+(G屋+G墙)496.91 kN柱底弯矩设计值M1.3Mp+0.6M风=489.22 kNm柱底剪力设计值V=1.3Vp+0.6V风=261.75 kNniiPMM1niiPVV122 Ssinkh21f山墙柱基础设计(独立基础)基础设计参数基础参数边长 X11.6m X21mX=2.6m Y=2.4m埋深 Z=1.5m基础及土平均重度 土20kN/m地下
36、水深度d=2m 柱自重(标准值)自重 G柱115kN偏心距-0.3m附加弯矩-34.5kNm山墙荷载(标准值):(墙体全部传至独立基础)自重 G墙328.5kN偏心距-0.52m附加弯矩M墙=G墙e墙-169.2kNm贮料荷载(标准值):(基础设计时,水平压力计算时可考虑 0)柱底水平弯矩Mp=Mpk0/k323.21kNm柱底水平剪力Vp=Vpk0/k=173.98kN剪力附加弯矩86.99kNm贮料自重61.056kN偏心距-1m自重弯矩-61.06kNm贮料弯矩合计349.15kNm屋面荷载(标准值):恒载:G屋=0.5FGS1S253.42kN活载:Q屋=0.5FGS1S212.72k
37、N偏心距e屋-0.52m恒载弯矩:M屋G=G屋e屋=-27.51kNm活载弯矩:M屋Q=Q屋e屋=-6.55kNm风荷载(标准值):柱底水平弯矩M风17.36kNm柱底水平剪力V风=6.69kN剪力附加弯矩3.34kNm风荷弯矩合计20.70kNm基础及基础以上土重度:G土=XYZ土=187.2kN地下水浮力F水=0kN 基础设计标准值轴力:558.0kN弯矩:#165 kN/m偏心距:e=Mk/(Nk+G土)=0.17m X 60.43m183 kN/m取Pmax165kN/m1.2Fa,通过 基础设计组合值(配筋采用理正工具箱计算)轴力:684.6kN弯矩:230.55 kNm 抗滑移验算
38、:基底摩擦系数=0.4抗滑移稳定系数k=1.3轴力:502.2kN剪力:178.0kN212.1kNV ,满足 2XX=e2柱2X21X=e222Bh墙柱柱柱eGM2/22hXhY G贮2X2X21=e22h贮贮贮贮eGM 0HZVMpv贮贮MMMMvp0HZVMv风风vMMM风风风屋柱屋墙柱QNkGGGG风屋屋贮墙柱MMMMMMMQk6.0G屋贮屋墙柱QN7.0G3.1)GGG(2.1风屋贮屋墙柱MMMMMMMQ6.07.03.10.1G)5.0322maxeXYGNPk(土21max6YXMXYGNPkk土风QVVp6.00.1贮屋墙柱GGGG9.0Nk)FG(NH水土敖间墙柱设计计算敖间
39、柱高 H1=10.5m地面以下柱高 H01m敖间柱总高H=H0+H1=11.5m混凝土容重 c25kN/m敖间柱截面宽 b30.4m敖间柱截面高 h30.49m檐墙柱距S1=10.6m敖间柱距S3=2.7m敖间墙厚度B3=0.49m墙体容重w19.00kN/m屋面恒载FG=2.1kN/m2屋面活载FQ=0.5kN/m2地圈梁高hL0=0.5m贮料对柱底弯矩标准值荷载P1P2P3P4P5P6P7Pi17.6533.2828.4022.2117.364.220.00a10.59.78.87.96.95.20015.2b11.82.73.64.66.29996.3Mi15.4146.5851.804
40、6.3338.338.730.00Vi17.4632.1226.2419.2813.752.670.00合计207.2 kNm111.52 kN柱自重 G柱=cb2H=115.0kN 山墙自重 G墙w(S2-b2)B2H1+cB2hL0 229.8kN 屋面恒载 G屋FGS1S2=60.1kN 屋面活载 Q屋FQS1S2 14.3kN 敖间墙柱内力设计值(配筋)墙体传递给柱压力折算系数 =1.00柱底轴力设计值N=Nc+(Nm+Nw)404.94 kN柱底弯矩设计值M1.3Mp=269.33 kNm柱底剪力设计值V=1.3Vp=144.98 kNniiPVV1niiPMM1敖间墙柱基础设计(独
41、立基础)基础设计参数基础参数边长 X3.2m Y=1m埋深 Z=1.5m基础及土平均重度 土20kN/m地下水深度d=2m柱自重(标准值)自重 G柱115kN山墙荷载(标准值):(墙体全部传至独立基础)自重 G墙229.8kN单侧贮料荷载(标准值):(基础设计时,水平压力计算时可考虑 0)柱底水平弯矩Mp=Mpk0/k181.81kNm柱底水平剪力Vp=Vpk0/k=97.86kN剪力附加弯矩48.93kNm贮料自重57.452kN偏心距-0.92m自重弯矩-53.00kNm贮料弯矩合计177.74kNm屋面荷载(标准值):恒载:G屋=FGS1S360.10kN活载:Q屋=FGS1S314.3
42、1kN基础及基础以上土重度:G土=XYZ土=96kN地下水浮力F水=0kN 基础设计标准值(地基承载力验算)单侧堆载情况:轴力:476.7kN弯矩:#283 kN/m偏心距:e=Mk/(Nk+G土)=0.31m X 60.53m296 kN/m取Pmax283kN/mFa,不通过两侧堆载情况:轴力:534.2kN基底反力:166.9kN/m1.2Fa,通过 基础设计组合值(配筋采用理正工具箱计算)单侧堆载情况:轴力:570.6 kN弯矩:231.06 kNm两侧堆载情况:轴力:645.3kN 抗滑移验算:基底摩擦系数=0.4抗滑移稳定系数k=1.3轴力:416.2kN剪力:97.86 kN15
43、7.6kNV ,满足2/3hXhY G贮3X41=eh贮贮贮贮eGM 0HZVMpv贮贮MMMMvp屋贮屋墙柱QNkGGGGmkMMdQN7.0G3.1)GGG(2.1mdwcmMM3.1pVV0.1屋贮屋墙柱QNkG2GGGXYNPkmax21max6YXMXYGNPkk土)5.0322maxeXYGNPk(土k)FG(NH水土贮屋墙柱GGGG9.0N屋贮屋墙柱QN7.0G23.1)GGG(2.1伸缩缝山墙柱设计计算山墙柱顶高 H1=10.5m地面以下柱高 H01m山墙柱总高H=H0+H1=11.5m混凝土容重 c25kN/m山墙柱截面宽 b20.4m山墙柱截面高 h20.8m檐墙柱距S1=
44、10.6m山墙柱距S2=4.8m山墙厚度B2=0.37m墙体容重w19kN/m屋面恒载FG=2.1kN/m2屋面活载FQ=0.5kN/m2地圈梁高hL0=0.5m贮料对柱底弯矩标准值荷载P1P2P3P4P5P6P7Pi31.3859.1750.5039.4830.867.510.00a10.59.78.87.96.95.20015.2b11.82.73.64.66.29996.3Mi27.4082.8192.0882.3668.1315.530.00Vi31.0357.1146.6534.2824.444.740.00合计368.3 kNm198.26 kN柱自重 G柱=cb2H=115.0k
45、N(单柱)山墙自重 G墙(w(S2-b2)B2H1+cB2hL0)328.5kN(单片)屋面恒载 G屋0.5FGS1S2=53.4kN(单侧)屋面活载 Q屋0.5FQS1S2 12.7kN(单侧)伸缩缝山墙柱内力设计值(配筋)墙体传递给柱压力折算系数 =1.00柱底轴力设计值N=G柱+(G屋+G墙)181.14 kN柱底弯矩设计值M1.3Mp=478.80 kNm柱底剪力设计值V=1.3Vp257.73 kNniiPMM1niiPVV1伸缩缝山墙柱基础设计(独立基础)基础设计参数基础参数边长 X3.6m Y=2.4m伸缩缝间距 s=0.48m埋深 Z=1.5m基础及土平均重度 土20kN/m地
46、下水深度d=2m 柱自重(标准值)双柱自重 G柱 230.0kN 山墙荷载(标准值):(墙体全部传至独立基础)双片自重 G墙 657.0kN 屋面荷载(标准值):双侧恒载:G屋=106.8kN 双侧活载:Q屋=25.4kN 单侧贮料荷载(标准值):(基础设计时,水平压力计算时可考虑 0)柱底水平弯矩Mp=Mpk0/k323.2kNm柱底水平剪力Vp=Vpk0/k=174.0kN剪力附加弯矩87.0kNm贮料自重121.1kN偏心距-1.205m自重弯矩-145.9kNm贮料弯矩合计264.3kNm基础及基础以上土重度:G土=XYZ土=259.2kN地下水浮力F水=0.0kN 基础设计标准值(地
47、基承载力验算)单侧堆载情况:轴力:1140.4kN弯矩:#213 kN/m偏心距:e=Mk/(Nk+G土)=0.19m X 60.60m241 kN/m取Pmax213kN/m1.2Fa,通过两侧堆载情况:轴力:1261.4kN基底反力:146.0kN/m1.2Fa,通过 基础设计组合值(配筋采用理正工具箱计算)单侧堆载情况:轴力:1367.8kN弯矩:343.57 kNm两侧堆载情况:轴力:1525.2kN 抗滑移验算:基底摩擦系数=0.4抗滑移稳定系数k=1.3轴力:1003.4kN剪力:174.0kN388.5kNV ,满足2/22sBXhY G贮贮贮贮eGM 0HZVMpv贮贮MMMM
48、vp屋贮屋墙柱QN7.0G3.1)GGG(2.1贮MM3.1pVV0.1贮屋墙柱GGGG9.0Nk)FG(NH水土sB22X41=e贮屋贮屋墙柱QNkGGGGmkMM)5.0322maxeXYGNPk(土屋贮屋墙柱QNkG2GGGXYNPkmax屋贮屋墙柱QN7.0G23.1)GGG(2.121max6YXMXYGNPkk土无筋砌体平房仓(散装仓)计算条件贮料名称小麦贮料密度=8KN/m外摩擦角=21.8内摩擦角=25摩擦系数=0.4墙体总高H=8.50m地下高度h1=0.50m储料堆高h=6.00m贮料上部高度h2=2.00m砌体截面信息砌体容重b19.8kN/m抗压强度设计值f2.31MP
49、a翼墙厚度1t10.24m翼墙厚度2t20.24m(平墙,T型取0)腹板高度hw0.51m(平墙取0)肋墙厚度tw0.37m(平墙取0)肋墙间距S1.2m(平墙取1.0)截面面积A=t1S+t2S+twhw=0.7647m形心距离0.495m0.495m截面惯性矩0.08785 m截面回转半径0.33895 m截面折算厚度1.17277 m截面抵抗距0.17748 m12 1122112/2(t/2)(/2)w wwww wt Sh hht S ttht S t ht Sy 3333121w112w22SySy(bt)(yt)(bt)(yt)3xI 2121wytthyAx xIi3.46Ix
50、hi12(y,y)xI W max荷载标准值计算侧压力系数k=cos2/cos1+(sin(+)sin)1/2/cos2=0.3562贮料水平压力作用水平压力标准值Ph,kkH=17.10kN/m仓底压力标准值Pv,k=H=48.00kN/m几何尺寸 a=h2+2h/3=6.00mb=h1+h/3=2.50m支座A反力(每米)7.44kN/m()墙底剪力(每米)43.85kN/m()墙底弯矩(每米)64.99kNm/m(逆时针)贮料对墙摩擦作用墙底轴力(每米)20.5151 kN/m()墙底弯矩(每米)10.155kNm/m(顺时针)砌体自重128.699kN ()土压对墙作用土容重 t18k