《IEC标准对应表.pdf》由会员分享,可在线阅读,更多相关《IEC标准对应表.pdf(5页珍藏版)》请在taowenge.com淘文阁网|工程机械CAD图纸|机械工程制图|CAD装配图下载|SolidWorks_CaTia_CAD_UG_PROE_设计图分享下载上搜索。
1、62271-203IEC:2003Common numbering of IEC 62271 publications falling under the responsibilityCommon numbering of IEC 62271 publications falling under the responsibilityof subcommittees SC 17A and SCof subcommittees SC 17A and SC。17c17cIEC 62271HIGHVOLTAGE SWITCHGEAR AND CONTROLGERseries高压开关设备和控制设备par
2、t12100101102103104105106107108109200New titleCommon specifications通用说明Seismic qualification for rated voltages of 72.5Kv and above72.5kV 及以上设备抗地震性能High-voltage alternating current circuitbreakers高压交流断路器Synthetic testing合成测试IEC 60694IEC 60056IEC 60427Old IEC numberif anyHighvoltage alternating curren
3、t disconnections and earthing switchesIEC 60129高压交流隔离开关和接地开关Switches for rated voltages above 1kV andless than 52kV1kV52kV 的开关设备Switches for rated voltages of 52 kV and above52kV 及以上的高压开关设备Alternating current switch-fuse combinations高压交流开关熔断器组合Alternating current contactors and contactorbased motors
4、tarters交流接触器和Alternating current switchgearfuse combinations高压交流开关设备熔断器组合Switchgear having combined function开关设备的联动功能Series capacitor bypass switches串连电容器IEC 602651IEC 602652IEC 60420IEC 60470AC metalenclosed switchgear and controlgear for rated voltage aboveIEC 602981kV and up to and including 52 k
5、V1kV52 kV 交流金属封闭开关和控制设备Insulation-enclosed switchgear and controlgear for rated voltage up toIEC 60466and including 52 kV52 kV 及以上绝缘封闭开关设备High-voltage/Lowvoltage prefabricated substations高低压箱式变电站Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV额定电压在 52 kV 以上气体绝缘金属封闭开关设备IEC 61330
6、IEC 60517201202203204High-voltage gas-insulated transmission lines for rated voltages of 72。5IEC 61640kV and above额定电压在 72.5 kV 及以上高压气体绝缘输电线路(300)Guide for seismic qualification of highvoltage alternating currentIEC 61166circuit-breakers高压交流断路器地震条件导则Guide for inductive load switching 感应负载开关导则(高压交流断路
7、器)IEC 61223(301)(302)Guide for short-circuit and switching test procedures for metal-enclosedIEC 61633and dead tank circuitbreakers金属封闭和落地罐式断路器的短路和开合试验程序导则Use and handling of sulphur hexafluoride(SF6)in highvoltageIEC 61634switchgear and controlgear高压开关和控制设备种 SF6 的使用和操作Additional requirements for en
8、closed switchgear and controlgear from 1IEC 60932kV to 72。5 kV to be used in severs climatic conditions1 kV 到 72.5 kV 封闭开关和控制设备用在特殊环境条件下的附加要求Cable connections for gasinsulated metal-enclosed switchgear forIEC 60859rated voltages above 52 kV.52 kV 及以上气体绝缘金属封闭开关设备的电缆连接Direct connection between power t
9、ransformers and gasinsulatedIEC 61639metal-enclosed switchgear for rated voltages above 52 kV.52 kV 及以上发电机变压器和气体绝缘金属封闭开关设备的直接连接Use of electronic and associated technologies in auxiliary equipment ofIEC 62063switchgear and controlgear开关设备和控制设备的辅助设备种电气和相关技术的使用Guide for asymmetrical shortcircuit breaki
10、ng test duty T 100a非对称短路开端试验导则-(303)(304)(305)(306)(307(308)(309)TRV parameters for highvoltage switchgear and controlgear for ratedvoltages above l kV and less than 100 kV.Electrical endurance testing for circuit-breakers rated 72。5 kV andabove72.5 kV 及以上的断路器的电动力续性试验(310)622712003IEC:2003Table 102T
11、able 102Preferred rated insulation levels for rated voltagesPreferred rated insulation levels for rated voltagesfor equipment of range 1for equipment of range 1Rated voltage forequipmentUrkV(r。m.s。value)设备额定电压Rated short-durationpower-frequency withstand voltage(额定短时工频耐受电压)UdkV(r.m.s。value)Phase-toe
12、arth,Across theRated lightning impulse withstandvoltage(额定雷电冲击耐受电压)UpkV(peckvalue)PhasetoAcross theacross openisolating distanceearth,acrossisolating distanceswitching device通过的绝缘距离open switching通过的绝缘距离and betweendevice andphasebetween phase相对地,相间和相对地,相间和通过断开的设备通过断开的设备(1)72。5100123145170245(2)140185
13、230275325460(3)160210265315375530(4)3254505506507501050(5)3755206307508601200NOTE Values in column(2)are applicableA)For type tests,phaseto-earth and between phases;B)For routine tests,phasetophase,and across the open switching device。Values in columns(3),(4)and(5)are applicable for type tests only。
14、注意:第二列的电压用于:(1)相对地和相间的测试类型(2)第三、四、五列种的电压值仅适用于相对地,相间和通过断开的开关设备的常规测试,622712003IEC:2003Table 103Table 103Preferred rated insulation levels for rated voltagesPreferred rated insulation levels for rated voltagesfor equipment of range IIfor equipment of range IIRated shortdurationpower-frequency withstand
15、 voltage(额定短时工频耐受电压)UdkV(r。m。s。value)across openswitching deviceand/or isolatingdistance(note 3)(3)5956758159251270Rated switching impulse withstand voltage(额定开关冲击耐受电压)UskV(r。m.s。value)Rated lightning impulse withstandvoltage(额定雷电冲击耐受电压)UpkV(peckvalue)across openswitching deviceand/or isolatingdista
16、nce(note 3)通过断开的开关设备和/或绝缘距离(8)1050(170)1175(205)1425(240)1550(315)2100(453)Rated voltage forequipmentUrPhasekV(r。m。s.value)to-earth,and设备额定电压between phase(note 3)相对地和相间(1)300362420550800(2)460520650710960Phasetoearth,and acrossopen switchingdevice相对地和相间(4)850950105011751425between phase(note 4)相间Acr
17、oss isolatingdistance(note 1,2and 3)通过绝缘距离Phase-toearth,andbetween phase相对地和相间(5)12751425157517602420(6)700(245)800(295)900(345)900(450)1100(650)(7)10501175142515502100NOTE 1 column(6)is also applicable to some circuit-breakers,see IEC 62271100.NOTE 2 in column(6),values in brackets are the peck val
18、ues of the power frequency voltage Ur/2/3 applied to the opposite terminal(combinedvoltage)In column(8),value in brackets are the peck values of the powerfrequency voltage 0.7 Ur/2/3 applied to the opposite terminal(combined voltage)。see annex D of IEC 60694.NOTE(3)Values in column(2)are applicable:
19、(a)for type tests,phase-toearth and between phases;(b)for routine tests,phaseto-earth,phase-to-phase,and across the open switching device。Values in columns(3),(4),(5),(6),(7)and(8)are applicable for type tests only.NOTE(4)these values are derived using the multiplying factors stated in Table 3 of IEC 60070-1(1993)注 1:第 6 列也适用于一些断路器,参见 IEC 62271-100。注 2:在第 6 列,括号内的数字是加在同一极相应端子上的反极性工频电压的峰值。注 3:第二列种的数字适用于:相间试验类型相对地,相间和通过断开的开关设备间的常规测试(3),(4),(5),(6),(7)和(8)列种的数值仅用于典型测试注 4: