1、电子秤操作规范Document Issue/Revision Status:文件发布/修订描述:Revision版本Release/revise Date 发布/修订日期Revise Outline制修纪要Author 作者Remark 备注Drafted by制订Checked by 审核Approved by 批准Department制订部门1. Purpose 目的:Provide the correct operation and maintenance methods of the electronic scales for the user. By ensure the magni
2、tude of accurate, reliable, stable of electronic scales, and extend its service life, to ensure the quality of products and measurement accuracy of results.为使用者提供电子秤的正确使用和保养方法,确保电子秤的量值准确、可靠、稳定和延长其使用寿命, 从而保证产品质量及测量结果的准确度。2. Range 范围For the companys in-service electronic scales.适用于本公司所有在用型号的电子秤。3. Aut
3、horities and responsibility 权责:3. 1. Quality Department calibration center is responsible for the measurement, repair and the calibrationafter repaired of the electronic scales.Guide the operator use and maintenance the device properly.3.1. 品质部计量中心负责电子秤的校准、维修和维修后再校准并指导操作者正确使用及保养。3. 2. The user depar
4、tment is responsible for the correct use of digital indicating scales , normal maintenance and submission on schedule.4. 2.各使用部门负责电子秤的正确使用、日常检查、维护保养及到期送检。5. Content 内容4. 1. Preparation before use1. 1.使用前准备1. 1. Electronic scales should be pasted with a label, no damage to the label, shedding and oth
5、er phenomena, and in the period of validity.If exceed the validity period , need send to the Quality Department to have re-test, calibration, labeling before use.4.1.1.电子秤应贴有标签,标签无损坏、脱落等现象,并且在有效期内,假设超过有效期需由品质部 计量中心重新测试、校准、贴标后才可使用。4. 1. 2. Environmental requirements: temperature 0 -40 , humidity = 80
6、% RH.4. 1.2.环境要求:温度0-40,湿度W80%RH。4. 1. 3. Place the electronic scales on a stable, flat desktop (do not place it on a rocking or shaking table). Use the adjusting feet to adjust the electronic scales to a level with the leveling bubble in the middle(if there is a balance device), keep it steady.4.1.
7、3.将电子秤放置于稳固、平坦的地面或桌面上(请勿放于摇动或有震动的台架上),利用调整 脚调整电子秤成水平,使其保持平稳,如有水平仪的那么注意秤上水平仪内气泡需位于圆圈中 央。4. 1. 4. Wipe electronic scale clean with clean paper.4. 1.4.用无尘纸擦干净电子秤。4. 1. 5. Structure drawings4. 1.5.结构附图Counting keysCumulative key计数键 | 累计键液晶显示器LCD MonitorLCD MonitorPeel/zero keySet buttonSwitcSet h keyShi
8、ft keyClear keyAlarm button4. 2. operation content4. 2.操作内容4. 2. 1. boot4. 2. 1.开机Turn on the power, press the switch key, when the electronic scale appears stable n0.00n or n0.0n (g), its mean the electronic scale performance is normal, enter the measurement interface, you can start weigh. Before u
9、sing the electronic scale,Youd better preheating 15-20 minutes to ensure the measurement available.接通电源,按开关键,当电子秤出现稳定的“000”或0.0 (g)时,表示电子秤性能正 常,进入测量界面,可以称重。使用电子秤前最好先预热15-20分钟,以确保测量。4. 2. 2. Weighing4. 2. 2.称重4. 2. 2. 1. Direct weighing methodPut the items on the pan. When a stable mark appears on th
10、e display, read the mass value.4. 2. 2.1.直接称重法将物品放到秤盘上。当显示器上出现稳定标记时,读出质量数值。4. 2. 2. 2. peeled weighing methodTo remove the container tare, put the container on the weighing platform first, press TARE after the value is stable, 0 will be displayed on the balance and put the weighing object in the con
11、tainer.Now the number displayed is the net weight of the item, remove the items and utensils, and the balance shows the negative value of the weight of the utensil. Press the TARE” key to return the display to 0”.4. 2. 2. 2.去皮称重法如需去除器皿皮重,那么先将器皿放于秤台上,待示值稳定后按“去皮”(TARE)键,天平显示“0” , 然后将需称重物品放于器皿上,此时显示的数字
12、为物品的净重,拿掉物品及器皿,天平 显示器皿重量的负值,仍按“去皮”键使显示回到“0”。4. 2. 3. counting method4. 2. 3.计数法2. 3. 1. In the case of an empty bench, place one or ten samples on the platform, the display shows the sample weight, and then press the COUNT key to display V and the right side of the display nPcsn light, indicating th
13、at the balance has entered the count state, and will put the number of samples as a unit, then press the unit conversion key, the display will switch between ” 1,10,20,50,100” , Select the number of samples in accordance with the selected number, and then placed the same type of object, the display
14、value is the total number of objects.Return to normal weighing state, justpress the ncountn (COUNT) Button.4. 2. 3.1.在空秤台的情况下,将一个或十个样本放于秤台上,显示窗显示样本重量,然后按一下 “计数”(COUNT)键,显示“1”,同时显示窗右部“pcs”灯亮,表示天平已进入计 数工作状态,且将所放样本数量计为1个单位,这时再按单位转换键,显示会在“1、 10、20、50、100”之间切换,选择和选定的样本数量相符合的数量,接下去再放置同 类物品,显示值即为物件总个数,此时要退
15、回到正常称重状态,只需再按一下“计数” (COUNT)键即可。5. Inspection and maintenance 点检和保养5. 1. Inspection method5. 1. 点检方法5. L L The mark on th。electronic scale should be clear and unbroken and within the validity period.5.L 1.电子秤上的标识应清晰无破损且在有效期内。5. 1. 2. Before using the weight for inspection, if it the range upper to 10
16、0kg, the accuracy is 20g5.L2. 使用前需用祛码点检,量程100kg以上的,精度要求20g。5. 2. maintenance methods5.2.保养方法5. 2. L The scales used is each workshop should be positioned and stored. Avoid places exposed to high temperature, dust, humidity or severe air flow.Such as direct sunlight or the air outlet of air condition
17、ers.5.2. 5各车间使用电子秤应定位使用和存放,应防止置于高温、多尘、潮湿或空气流动剧烈之场所使用,如LI光直射或空调机之出风门处。5. 2 2. Weighing should not shake the electronic scales, avoid place samples on the electronic scale for a long time.5.2. 2. 称重时,不得摇动电子秤,不得将称定的物品长时间放置在电子秤上。5. 2. 3. After the electronic scale is installed, the scales should be kept
18、 level, avoid the vibration and impact5. 2.3.电子秤安装就位后,称重要保持水平,防止振动和冲击。5. 2 4. platform and the should always be gently scrubbed with a soft cloth o a damp cloth, avoid be scrubbed with strong solvents (such as benzene, nitro-besed oil).5.2.4. 秤台和外壳必须经常用软布或湿布轻轻擦洗,切不可用强溶剂(如苯、硝基类油)擦洗。5. 2. 5. Clean up
19、in time, prevent dust pollution,5. 2.5.及时清理卫生,防止粉尘污染。5. 2. 6. Daily work, turn off thdevice in time. Unplug the power cord as get off work.5.2.6. 每日结束工作,注意关机。下班时要拔下电源线。5 2. 7. When the electronic scale is idle or unmanned, forbidden to place the object on the scale to avoid damaging the sensor.5.2.7
20、. 电子秤闲置或无人称重时,严禁在秤上放置物品,以免损坏传感器。5. 2. 8. Forthe electronic balance in the liquid injection workshop need packaging protect the shell. When powdered solid electrolyte cover the scale surface, should remove it immediately, he great deal of accumulation is foibiddan.6. 2. 8.对注液车间使用的电子秤要求对其外壳进行包装防护,秤面上出
21、现粉末状固体电解液时,应 立即清除,严禁出现大量堆积现象。7. Precautions 考前须知1. When electronic scale in using, objects should be placed in the center of the weighing pan, and objects weight shouldnt exceed the maximum range of electronic scale, avoid to damaging the electronic scale.6.1. 电子秤使用时,称物应位于秤盘的中心位置,且称物不得超过电子秤的最大秤重,以免损坏电子 秤。6. 2. Should use the original charger for charge.6. 2.应使用原配的充电器充电。保密等级:D级