《最新QTZ5013-B塔吊非标准附墙设计.doc》由会员分享,可在线阅读,更多相关《最新QTZ5013-B塔吊非标准附墙设计.doc(14页珍藏版)》请在taowenge.com淘文阁网|工程机械CAD图纸|机械工程制图|CAD装配图下载|SolidWorks_CaTia_CAD_UG_PROE_设计图分享下载上搜索。
1、Four short words sum up what has lifted most successful individuals above the crowd: a little bit more.-author-dateQTZ5013-B塔吊非标准附墙设计瑞安华峰专家园塔吊非标准附墙设计瑞安华峰专家园塔吊非标准附墙设计谢建民1 王建宏2 章旭江2(1.浙江广厦建设职业技术学院,浙江 东阳 322100;2.东阳第三建筑工程有限公司,浙江 东阳 322100)摘 要:瑞安华峰专家园塔吊非标准附墙设计采用平面杆系电算程序进行精确计算。该塔吊从投入使用至工程竣工,虽经历过台风,仍运行良好,
2、表明其设计合理可行。关键词:塔吊 附墙 平面杆系 计算The Design of The Non-Standard Attaching Wall of HuaFeng Professor in RuianXie Jianmin Wang Jianhong Zhang Xujiang(1.Guangsha College of Applied Construction Technology, Dong Yang322100, Zhejiang; 2. Dong Yang No.3 Architectural Engineering Ltd.Co. Dong Yang 322100, Zhejia
3、ng)Abstract: The design of the non-standard attaching wall of Huafeng professor in Ruian accounts accurately with computer. From the operation to the project completion, though its gone typhoon, the tower crane goes very well, it indicates that the design if reasonable.Key words: tower crane; attach
4、ing wall; plane poles; calculate 1 工程概况浙江省瑞安市华峰专家园工程为框剪结构,地上十六层、地下一层,总建筑面积29505.83m2。其中地上建筑面积25036.06m2,地下建筑面积为4469.77 m2,落地长99.24米,宽45.04米,室内外高差0.15m,0.000标高相当于吴淞高程6.880m,地下室标高为 -4.8m。竖向运输采用塔吊QTZ5013B。2 附墙方案由于施工准备阶段塔吊定位不妥,造成塔吊附墙十分困难,塔吊距建筑物主体最近距离为7.8m,最远达11.1m,通过多方案比较后采用不规则钢桁架,见图1,结构平面见图2,竖向支承见图3。3
5、计 算标准附墙杆作用至非标准附墙钢桁架节点A、B(图2)的力由塔吊厂方提供产品使用说明书确定,按B点水平作用力正反两个方向受力考虑二个工况,计算简图见图4-A与图5-A,钢桁架所有节点按铰接考虑,采用平面杆系电算程序计算,计算结果见图4-B和图5-B,现验算BF和AE两杆的稳定性,所有杆件均采用组合216。图1 非标准附墙平面布置图 BC杆:,根据钢结构设计规范GB50017-2003表5.1.2-1,该组合槽钢属于B类型截面,查规范附录C,得。按规范GB50017-2003公式(5.1.2-1)计算:AE杆:,满足要求。4 方案实施钢桁架平面布置图见图2。3.1 关于构件由于该非标准附墙钢构件长度较长,自重较大,采用在A、B两点加二道斜钢支撑和三道钢丝绳斜拉方案,钢斜撑见图3。图2 不规则钢桁架结构平面图3.2 钢桁架与主体连接钢桁架各构件采用组合2个16槽钢,在楼面大梁和楼板上二点固定,见图2与图6,槽钢伸主楼面长度不少于1200mm,故每个钢构件在楼面位置上预埋二个预埋件,并与钢桁架构件焊接固定。该方案实施后,经历过多次台风考验,直至工程完工,运行情况仍然良好。实践证明该设计方案合理可行。 图3 竖向钢斜撑图4 工况A图5 工况B图6 水平杆件与楼层连接详图-