《PE、PVC、PPR、镀锌管、不锈钢管型号与规格.pdf》由会员分享,可在线阅读,更多相关《PE、PVC、PPR、镀锌管、不锈钢管型号与规格.pdf(29页珍藏版)》请在taowenge.com淘文阁网|工程机械CAD图纸|机械工程制图|CAD装配图下载|SolidWorks_CaTia_CAD_UG_PROE_设计图分享下载上搜索。
1、1.PE801.PE80 级聚乙烯管材公称压力和规格尺寸级聚乙烯管材公称压力和规格尺寸产品规格尺寸产品规格尺寸:给水用给水用 PE80PE80 聚乙烯聚乙烯(PE)(PE)管材管材公称外公称壁厚 en,mm长度径dnSDR33SDR21SDR17SDR13.6SDR11L公称压力,MPamm0.40.60.811.25mm20-2.32.3600025-22.32.332-22.43900040-22.333.750222.83.74.61200063233.64.75.8752.33.64.55.66.8902.84.35.46.78.21103.45.36.68.1101253.867.4
2、9.211.41404.36.78.310.312.71604.97.79.511.814.61805.58.610.713.316.42006.29.611.914.718.22256.910.813.416.620.52507.711.914.818.422.72808.613.416.620.625.43159.71518.723.228.635510.916.921.126.132.240012.319.123.729.436.345013.821.526.733.140.950015.323.929.736.845.456017.226.733.241.250.863019.3303
3、7.446.357.271021.833.942.152.2-80024.538.147.458.8-90027.642.953.3-100030.647.759.3-管材物理机械性能管材物理机械性能序号项目20静液压强度(环向应力 9.0Mpa,100h)80静液压强度(环向应力 4.6Mpa,165h)80静液压强度(环向应力 4.0Mpa,1000h)断裂伸长率,%纵向收缩率(110),%氧化诱导时间(200),min耐候性1)(管材累计接受3.5GJ/m2老化能量后指标1不破裂、不渗漏不破裂、不渗漏不破裂、不渗漏3503202345680静液压强度(环向应力不破裂、4.6Mpa,165
4、h)不渗漏断裂伸长率,%350氧化诱导时间7(200),min10注 1)仅适用于蓝色管材给水用给水用 PE100PE100 聚乙烯聚乙烯(PE)(PE)管材管材公称外公称壁厚 en,mm径dnSDR26SDR21SDR17SDR13.6SDR11公称压力,MPamm0.60.811.251.6323403.7504.6634.75.8754.55.66.8904.35.46.78.2长度Lmm60009000120001104.25.31254.861405.46.71606.27.71806.98.62007.79.62258.610.82509.611.928010.713.431512
5、.11535513.616.940015.319.145017.221.550019.123.956021.426.763024.13071027.233.980030.638.190034.442.9100038.247.7管材物理机械性能管材物理机械性能序号项目20静液压强度(环向应力 12.4Mpa,100h)80静液压强度(环向应力 5.5Mpa,165h)80静液压强度(环向应力 5.0Mpa,1000h)断裂伸长率,%纵向收缩率(110),%氧化诱导时间(200),min6.67.48.39.510.711.913.414.816.618.721.123.726.729.733.2
6、37.442.147.453.359.38.19.210.311.813.314.716.618.420.623.226.129.433.136.841.246.352.258.8-1011.412.714.616.418.220.522.725.428.632.236.340.945.450.857.2-指标1不破裂、不渗漏不破裂、不渗漏不破裂、不渗漏350320234567耐候性1)(管材累计接受3.5GJ/m280静液压强度(环向应力不破裂、5.5Mpa,165h)不渗漏断裂伸长率,%350老化能量氧化诱导时间后(200),min10注 1)仅适用于蓝色管材2.2.饮水用饮水用 PVC-
7、UPVC-U 管材的性能技术指标管材的性能技术指标饮水管材技术说明饮水管材技术说明饮水管材 0.63MPa编号ZCVC-GS-1-1ZCVC-GS-1-2ZCVC-GS-1-3ZCVC-GS-1-4ZCVC-GS-1-5ZCVC-GS-1-6ZCVC-GS-1-7ZCVC-GS-1-8ZCVC-GS-1-9ZCVC-GS-1-10ZCVC-GS-1-11ZCVC-GS-1-12ZCVC-GS-1-13ZCVC-GS-1-14ZCVC-GS-1-15ZCVC-GS-1-16ZCVC-GS-1-17ZCVC-GS-1-18饮水管材 1.0MPa编号ZCVC-GS-2-1ZCVC-GS-2-2ZCV
8、C-GS-2-3ZCVC-GS-2-4ZCVC-GS-2-5ZCVC-GS-2-6ZCVC-GS-2-7ZCVC-GS-2-8ZCVC-GS-2-9ZCVC-GS-2-10ZCVC-GS-2-11ZCVC-GS-2-12ZCVC-GS-2-13ZCVC-GS-2-14ZCVC-GS-2-15ZCVC-GS-2-16ZCVC-GS-2-17ZCVC-GS-2-18规格2025324050637590110125160180200225250315355400饮水管材 1.6MPa编号ZCVC-GS-3-1ZCVC-GS-3-2ZCVC-GS-3-3ZCVC-GS-3-4ZCVC-GS-3-5ZC
9、VC-GS-3-6ZCVC-GS-3-7ZCVC-GS-3-8ZCVC-GS-3-9ZCVC-GS-3-10规格2025324050637590110160规格2025324050637590110125160180200225250315355400饮水用饮水用 PVC-UPVC-U 管材的性能技术指标管材的性能技术指标序号12345678910111213项目执行标准外观规格尺寸(外径、壁厚)密度维卡软化温度纵向回缩率%二氯甲烷浸渍落锤冲击试验 TIR液压试验连接密封试验卫生性能氯乙烯单体含量长度性能要求GB/T10002.1-2006管材内外表面应光滑,无明显划痕、无凹陷、可见杂质和其他
10、影响本部分要求的表面缺陷。管材端面应切割平整并与轴线垂直。符合公差要求1350146080C5%表面变化不劣于 4N5%无破裂、无渗漏无破裂、无渗漏符合 GB/T17219-19981.0mg/kg一般产生 4 米、6 米的平口管、平扩口或活套管,也可以根据客户的要求供货3.PP-R3.PP-R 冷热管材的性能技术指标冷热管材的性能技术指标PP-RPP-R 冷热管材的性能技术指标冷热管材的性能技术指标1、标准我公司的 PP-R 管材产品完全执行国家标准 GB/T18742.2-2002。2、颜色PP-R 产品分为咖喱色和白色。3、压力等级我公司 PP-R 管材有 S5、S4、S3.2、S2.5
11、 等 4 个管系列,通常热水管道有 S3.2、S2.5 两个管系列,冷水管道系统用 S5、S4、S3.2 三个管系列。在管道系统设计中,按不同使用要求,安全系数可取 1.25 或 1.5。管系列与公称压力 PN 的对应关系详见下表:管系列管系列 S S 与公称压力与公称压力 PNPN 的关系的关系管系列公称压力 MPaC=1.25S51.25S51.0S41.6S41.25S3.22.0S3.21.6S2.52.5S2.52.0管系列公称压力 MPaC=1.5PP-RPP-R 冷热管材的性能技术指标冷热管材的性能技术指标-规格及尺寸规格及尺寸公称外径2025324050637590110平均外
12、径min20.025.032.040.050.063.075.090.0110.0max20.325.332.340.450.563.675.790.9111.0S52.02.32.93.74.65.86.88.210.0S 系列公称壁厚S42.32.83.64.55.67.18.410.112.3S3.22.83.54.45.56.98.610.312.315.1S2.53.44.25.46.78.310.512.515.018.34.PP-R4.PP-R 管施工安装管施工安装简介:简介:PP-R 管施工安装中的一般规定、敷设安装要点、连接要点、支吊架安装、试压、清洗、消毒、安全施工、贮运等
13、关键字:关键字:PP-R 管 安装一、一般规定一、一般规定1、管道在安装施工前,应具下列条件:a 施了图纸及其它技术文件齐全,且已进行图纸技术交底,满足施工要求;b 施工方案、施工技术、材料机具供应等能保证正常施工;c 施了人员应经过建筑给水聚丙烯管道安装的技术培训。2、提供的管材和管件应符合设计规定,并附有产品说明书和质量合格证书。3、不得使用有损坏迹象的材料。如发现管道质量有异常,应在使用前进行技术鉴定或复检。4、管道系统安装过程中的开口处应及时封堵。5、施工安装时应复核冷、热水管压力等级和使用场合。管道标记应面向外侧,处于显眼位置。二、管道敷设安装要点二、管道敷设安装要点1、管道嵌墙暗敷
14、时,宜配合土建预留凹槽,其尺寸设计无规定时,嵌墙暗管墙槽尺寸的深度为 De 十 20mm,宽度为干 De4060mm。凹悄表面必须平整,不得有尖角等突出物,管道试压合格后,墙槽用 M75 级水泥砂浆填补密实。2、管道暗敷在地坪面层内,应按设计图纸位置进行。如现场施了有更改,应有图示记录。3、管道安装时,不得有轴向扭曲,穿墙或楼板时,不宜强制校正。给水聚丙烯管与其它金属管道平行敷设时应有一定的保护距离,净距离下宜小于 100mm,且聚丙烯管宜它在金属管道的内侧。4、室内明装管道,宜在土建粉饰完毕后进行,安装前应配合土建正确预留孔洞或顶理套管。5、管道穿越楼板时,应设置钢套管,套管高出地面 50m
15、m,并有防水措施。管道穿越屋面时,应采取严格的防水措施。穿越前端应设固定支架。6、热水管道穿墙壁时,应配合土建设置钢套管,冷水管穿墙时,可预留洞,洞口尺寸较外径大 50mm。7、直埋在地坪面层以及墙体内的管道,应在封蔽前做好试压和隐蔽工程的验收记录了作。8、建筑物理地引入管和室内埋地管敷设要求如下:a室内地坪士0.00 以下管道铺设宜分两阶段进行。先进行地坪士 000 以下至娃础墙外壁段的铺设;侍土建施工结束后,再进行户外连接管的铺设;b室内地坪以下管道铺设应在上建工程回填土夯实以后,重新开挖进行。严禁在回填土之前或未经夯实的土层中铺设;c铺设管道的沟底应平整,个得有突出的尖硬物体。土壤的颗粒
16、径不宜大于 12mm,必要时对铺 100mm 厚的砂垫层。d 埋地管道回填时,管周回填土不得夹杂尖硬物自接与管壁接触。应先用砂土或颗粒径不大于 12mm 的土壤回填至管顶上侧 300mrn处,经夯实后方可回填原土。室内埋地管道的埋置深度不宜小于 300mnl;e管道出地坪处应设置护管,其高度应高出地评 100mnl;f管道在穿基础墙时,应设置金属套管。套管与基础墙预留孔上方的净空高度,特设计不应小于 100mm;g管道在穿越街坊道路,覆土厚度小于 700mm 时,应采取严格的保护措施。三、管道连接要点1、同种材质的给水聚丙烯管及管配件之间,安装应采用热熔连接,安装应使用专用热熔工具。暗效墙体、
17、地坪面内的管道不得采用丝扣或法兰连接。2、给水聚丙烯管与金属管件连接,应采用带金属管件的聚丙烯管件作为过渡,该管件与塑料管采用热熔连接,与金属配件或卫生洁具五金配件采用丝们连接。3、热熔连接应按下列步骤进行:a接通热熔以电源,到达工作温度指示灯亮后方能开始操作;b切割管村,必须使端面表在于管轴线。管材切割一般使用管子剪或管道切削机。必要时可使用锋利的钢锯,但切割后管材断面应去除毛边和毛刺;c管村与管件连接端面必须清洁、干燥、无油;d用卡尺和合适的笔在管端测量并标绘出热熔深度,热熔深度应符合表 9。表 9热熔连接技术要求公称外径(mm)热熔深度(mm)20142516322040215022.5
18、63247526903211038.5加热时间(mm)加工时间(S)冷却时间(mm)5781218243040504446661010153344568810注:若环境温度小于 5,加热时间应延长 50。e熔接弯头或三通时,按设计图纸要求,应注意其方,气在管件和管材的直线方向上,用辅助标志标出其位置;f连接时,无旋转地把管端导入加热套内,插入到所标志的深度,同时,无旋转地把管件推到加热头上,达到规定标志处。加热时间,必须满足表 9 的规定;g达到加热时间后,立即把管材与管件从加热套与加热头上同时取下,迅速无旋转地直线均匀插入到所标深度,使接头处形成均匀凸缘;h在表 9 规定的加工时间内,刚熔接
19、好的接头还可校正,但严禁旋转。4、当管道采用电熔连接时,应符合下列规定:a应保持电熔管件与管材的熔合部位不受潮;b电熔承插连接管材的连接端应切割垂直,并应用洁净棉布擦净管材和管件连接面上的污物,并标出插入深度,刮除其表皮;c校直两对应的连接件,使其处于同一轴线上;d电熔连接机具与电熔管件的导线连通应正确。连接前,应检查通电加热的电压,加热时间应符合电熔连接机具与电熔管件生产厂家的有关规定;e在熔合及冷却过程中,不得移动、转动电熔管件和熔合的管道,不得在连接件上施加任何压力;f电熔连接的标准加热时间应由生产厂家提供,并应随环境温度的不同而加以调整。电熔连接的加热时间与环境温度的关系应符合表 10
20、 的规定。若电熔机具有温度自动补偿功能,则不需调整加热时间。表 10电熔连接的加热时间与环境温度关系环境温度1001020304050修正值T12TT8TT4T标准加热时间 TT4TT8TT12T加热时间(S)1121081041009692885、与管道采用法兰连接时,应符合下列规定:a法兰盘套在管道上。bPPR 过渡接头与管道热熔连接步骤应符合 3.3。c校直两对应的连接件,使连接的两片法兰垂直于管道中心线,表面相互平行。d法兰的衬垫,应采用耐热无毒橡胶圈。e应使用相同规格的螺栓,安装方向一致。螺栓应对称紧固。紧固好的螺栓应露出螺母之外,宜齐平。螺栓螺帽宜采用镀锌件。f连接管道的长度应精确
21、,当紧固螺栓时,不应使管道产生轴向拉力。g法兰连接部位应设置支吊架。四、支吊架安装四、支吊架安装1、管道安装时必须按不同管径和要求设置管卡和支吊架,位置应准确,埋设要平整,管卡与管道接触应紧密,但不得损伤管道表面。2、采用金属管卡和支吊架时,金属管卡与管道之间应采用塑料带或橡胶等软物隔垫。在金属管配件与给水聚丙烯管连接部位,管长应设在金属配件一端。3、立管和横管支吊架的间距不得大于表 5 的规定。表 5给水管支吊架最大间距公称外径2025324050637590110De(mm)横管650800950110012501400150016001900冷(mm)主管水100012001500170
22、018002000200021002500(mm)五、试压五、试压1、冷水管试验压力,应为管道系统工作压力的 15 倍。但不得小于 10MPa。2、热水管试验压力,应为管道系统工作压力的 20 倍。但不得小于 15MPa。3、管道水压试验应符合下列规定:a热熔连接管道,水压试验时间应在 24h 后进行;b水压试验前,管道应固定,接头需明露;c管道注满水后,先排出管道内空气,进行水密性检查;d加压宜用手动泵,升压时间不小于 10min,测定仪器的压力精度应为 0.0lMPa。e至规定试验压力,稳压 lh,测试压力降不得超过 0.06Mpa。f在工作压力的 115 倍信状态下,稳压 2h,压力降不
23、得超过 0.03Mpa;同时检查各连接处不得渗漏。4、直埋在地坪面层和墙体内的管道,试压工作必须在面层浇捣或封堵前进行,达到试压要求后,土建方能继续施工。六、清洗、消毒六、清洗、消毒1、给水管道系统在验收前,应进行通水冲洗。冲洗水流速宜大于Zm/s,冲洗时,不应留死角,每个配水点龙头应打开,系统最低点应设放水口,清洗时间控制在冲洗出口处排水的水质与进水相当为止。2、生活饮用水系统经冲洗后,还应用 2030mg/l 的游离氯的水灌满管道进行消毒。含氯水在管中应滞留 24h 以上。3、管道消毒后,再用饮用水冲洗,并经卫生管理部门取样检验,水质符合现行的国家标准生活饮用水卫生标准后,方可交付使用。在
24、 30 分钟内,允许两次升压,升至规定试验压力。七、安全施工:七、安全施工:l、管道连接使用热熔工具时,应遵守电器工具安全操作规程,注意防潮和脏物污染。2、操作现场不得有明火,严禁对给水聚丙烯管村进行明火烘弯。3、别给水聚丙烯管道不得作为攀拉、吊架等使用。4、直埋暗管对蔽后,应在墙面或地面标明暗管的位置和走向,严禁在管上冲击或钉金属钉等尖锐物体。八、贮运八、贮运1、搬管材和管件时,应小心轻放,避免油污,严禁剧烈撞击、与尖锐物品碰触和抛、摔、滚、拖。2、管材和管件应存放在通风良好的库房或简易棚内,不得露天存放,防上阳光直射,注意防火安全,距离热源不得小于 lm。3、管材应水平堆放在平整的地上,应
25、避免弯曲管材,堆置高度不得超过 15in,管件应逐层码堆,不宜叠得过高。表 电熔管件承口尺寸及偏差(mm)公称外径公称外径熔融区域熔融区域加热长度加热长度DeDe平均内径平均内径 D1D1L2L22020.1102525.1103232.110插入深度插入深度 L1L1最最小小最最大大203720402044405063759011040.150.163.275.290.2110.3101011121315202023252832495563707982管件的承口尺寸及偏差(mm)公称外径公称外径2025324050637590110承口内径承口内径基本尺寸基本尺寸基本尺寸基本尺寸-19.3-
26、0.2-24.3-0.3-31.3-0.3-39.2-0.3-49.2-0.4-62.1-0.4-73.95-0.5-88.85-0.5-108.65-0.6基本尺寸基本尺寸16基本尺寸基本尺寸182022承口壁厚不应小于同规格管材的壁厚25293135.541.5表系指热熔连接管件.颜色有:白色,灰色,绿色5.PP-R5.PP-R冷热水管道系异径三通规格冷热水管道系异径三通规格规格25/20/2025/20/2520/25/2032/20/3232/25/3240/20/4040/25/4040/32/4050/20/5050/32/5050/40/5063/25/6363/32/6363/
27、40/6363/50/6375/40/7575/50/7575/63/7590/63/9090/75/90110/63/110110/75/110110/90/1106.6.镀锌管规格镀锌管规格镀锌管相关资料镀锌管相关资料钢管重量计算公式钢管重量计算公式:(:(外径外径-壁厚壁厚)*)*壁厚壁厚*0.02466=kg/*0.02466=kg/米米(每米的重量每米的重量)规格公称内径(毫米)DN15DN20DN25DN32DN40DN50DN65DN80DN100DN125DN150DN200英寸1/23/411.251.522.534568外径 mm 壁厚 mm 最小壁 焊管(6 米定尺)镀锌
28、管(6 米定尺)厚 mm米重 kg 根重 kg 米重 kg 根重 kg21.326.933.742.448.360.376.188.9114.3140168.3219.12.82.452.82.453.22.83.53.063.53.063.83.3254.03.54.04.04.54.5 6.0(焊管)1.281.662.413.363.875.297.118.3810.8815.0418.1831.537.689.9614.4620.1623.2231.7442.6650.2865.2890.24109.08189.181.3571.762.5543.564.105.6077.5368.8
29、811.5315.94219.278.1410.5615.3221.3624.6033.6445.2153.2869.1898.65115.62DN2008219.1 6.5(热镀锌)36.12216.72镀锌钢管尺寸规格表公称口径 外径壁厚镀锌管壁黑铁管增加的重量系数MMMMMM普通钢管加厚钢管610.02 1.0641.059813.52.751.0561.0461017.03.501.0561.0461521.33.151.0471.0392026.83.401.0461.0392533.54.251.0391.0323242.35.151.0391.032公称口径 外径壁厚镀锌管壁黑铁
30、管增加的重量系数MMMMMM普通钢管加厚钢管4048.04.001.0361.0305060.05.001.0361.0286575.55.251.0341.0288088.54.251.0321.027100114.07.001.0321.026125140.07.501.0281.023150165.07.501.0281.023镀锌钢管尺寸规格表说明:W=C0.02466(D-S)SW-镀锌管每米重量:kg/mC-镀锌管比黑铁管增加的重量系数D-黑铁管的外径S-黑铁管的壁厚7.7.不锈钢管规格不锈钢管规格.圆管编号0611ZY08040611ZY09040611ZY09050611ZY0
31、9060611ZY09070611ZY09080611ZY09090611ZY09100611ZY102100611ZY102120611ZY102150611ZY102200611ZY102250611ZY114120611ZY114150611ZY114200611ZY114250611ZY12040611ZY12050611ZY12060611ZY12070611ZY12080611ZY12090611ZY12100611ZY12120611ZY12707名称80.4 圆管9.50.4 圆管9.50.5 圆管9.50.6 圆管9.50.7 圆管9.50.8 圆管9.50.9 圆管9.51
32、.0 圆管1021.0 圆管1021.2 圆管1021.5 圆管1022.0 圆管1022.5 圆管1141.2 圆管1141.5 圆管1142.0 圆管1142.5 圆管12.70.4 圆管12.70.5 圆管12.70.6 圆管12.70.7 圆管12.70.8 圆管12.70.9 圆管12.71.0 圆管12.71.2 圆管12.70.7 圆管0611ZY127100611ZY127150611ZY127200611ZY133150611ZY133200611ZY133300611ZY14040611ZY14050611ZY14090611ZY141150611ZY141200611ZY
33、141250611ZY14300611ZY159150611ZY159200611ZY159250611ZY16040611ZY16050611ZY16060611ZY16070611ZY16080611ZY16090611ZY16100611ZY16120611ZY16150611ZY168200611ZY168250611ZY168300611ZY19040611ZY190512.71.0 圆管12.71.5 圆管12.72.0 圆管1331.5 圆管1332.0 圆管1333.0 圆管140.4 圆管140.5 圆管140.9 圆管1411.5 圆管1412.0 圆管1412.5 圆管1
34、413.0 圆管1591.5 圆管1592.0 圆管1592.5 圆管160.4 圆管160.5 圆管160.6 圆管160.7 圆管160.8 圆管160.9 圆管161.0 圆管161.2 圆管161.5 圆管1682.0 圆管1682.5 圆管1683.0 圆管190.4 圆管190.5 圆管0611ZY19060611ZY19070611ZY19080611ZY19090611ZY19100611ZY19120611ZY19150611ZY219200611ZY219300611ZY22040611ZY22050611ZY22060611ZY22070611ZY22080611ZY22
35、090611ZY22100611ZY22120611ZY22150611ZY22200611ZY25040611ZY25050611ZY25060611ZY25070611ZY25080611ZY25090611ZY25100611ZY25120611ZY25140611ZY25150611ZY2520190.6 圆管190.7 圆管190.8 圆管190.9 圆管191.0 圆管191.2 圆管191.5 圆管2192.0 圆管2193.0 圆管220.4 圆管220.5 圆管220.6 圆管220.7 圆管220.8 圆管220.9 圆管221.0 圆管221.2 圆管221.5 圆管22
36、2.0 圆管250.4 圆管250.5 圆管250.6 圆管250.7 圆管250.8 圆管250.9 圆管251.0 圆管251.2 正标圆管251.4 正标圆管251.5 正标圆管252.0 正标圆管0611ZY32050611ZY32060611ZY32070611ZY32080611ZY32090611ZY32100611ZY32120611ZY32150611ZY32200611ZY38060611ZY38070611ZY38080611ZY38090611ZY38100611ZY38120611ZY38150611ZY38200611ZY51060611ZY51070611ZY51
37、080611ZY51090611ZY51100611ZY51120611ZY51150611ZY51200611ZY63070611ZY63080611ZY63090611ZY63100611ZY6312320.5 正标圆管320.6 正标圆管320.7 正标圆管320.8 正标圆管320.9 正标圆管321.0 正标圆管321.2 正标圆管321.5 正标圆管322.0 正标圆管380.6 正标圆管380.7 正标圆管380.8 正标圆管380.9 正标圆管381.0 正标圆管381.2 正标圆管381.5 正标圆管382.0 正标圆管510.6 正标圆管510.7 正标圆管510.8 正标
38、圆管510.9 正标圆管511.0 正标圆管511.2 正标圆管511.5 正标圆管512.0 正标圆管630.7 正标圆管630.8 正标圆管630.9 正标圆管631.0 正标圆管631.2 正标圆管0611ZY63150611ZY63400611ZY76080611ZY76090611ZY76100611ZY76120611ZY76150611ZY76200611ZY89090611ZY89100611ZY89120611ZY89150611ZY89200611ZY8930.正标方管编号0612ZF1010040612ZF1010050612ZF1010060612ZF101007061
39、2ZF1212040612ZF1212050612ZF1212060612ZF1212070612ZF1212080612ZF1616040612ZF1616050612ZF1616060612ZF161607631.5 正标圆管634.0 正标圆管760.8 正标圆管760.9 正标圆管761.0 正标圆管761.2 正标圆管761.5 正标圆管762.0 正标圆管890.9 正标圆管891.0 正标圆管891.2 正标圆管891.5 正标圆管892.0 正标圆管893.0 正标圆管名称10100.4 正标方管10100.5 正标方管10100.6 正标方管10100.7 正标方管12120
40、.4 正标方管12120.5 正标方管12120.6 正标方管12120.7 正标方管12120.8 正标方管16160.4 正标方管16160.5 正标方管16160.6 正标方管16160.7 正标方管0612ZF1616080612ZF1616090612ZF1616100612ZF1616120612ZF1919040612ZF1919050612ZF1919060612ZF1919070612ZF1919080612ZF1919090612ZF1919100612ZF1919120612ZF1919150612ZF2222040612ZF2222050612ZF2222060612Z
41、F2222070612ZF2222080612ZF2222090612ZF2222100612ZF2222120612ZF2525050612ZF2525060612ZF2525070612ZF2525080612ZF2525090612ZF2525100612ZF2525120612ZF2525150612ZF25252016160.8 正标方管16160.9 正标方管16161.0 正标方管16161.2 正标方管19190.4 正标方管19190.5 正标方管19190.6 正标方管19190.7 正标方管19190.8 正标方管19190.9 正标方管19191.0 正标方管19191
42、.2 正标方管19191.5 正标方管22220.4 正标方管22220.5 正标方管22220.6 正标方管22220.7 正标方管22220.8 正标方管22220.9 正标方管22221.0 正标方管22221.2 正标方管25250.5 正标方管25250.6 正标方管25250.7 正标方管25250.8 正标方管25250.9 正标方管25251.0 正标方管25251.2 正标方管25251.5 正标方管25252.0 正标方管0612ZF3030060612ZF3030070612ZF3030080612ZF3030090612ZF3030100612ZF3030120612Z
43、F3030150612ZF3838060612ZF3838070612ZF3838080612ZF3838090612ZF3838100612ZF3838120612ZF3838150612ZF3838200612ZF5050070612ZF5050080612ZF5050090612ZF5050100612ZF5050120612ZF5050150612ZF5050200612ZF5050250612ZF808012.正标矩形管编号0612ZJ2010040612ZJ2010050612ZJ20100630300.6 正标方管30300.7 正标方管30300.8 正标方管30300.9 正
44、标方管30301.0 正标方管30301.2 正标方管30301.5 正标方管38380.6 正标方管38380.7 正标方管38380.8 正标方管38380.9 正标方管38381.0 正标方管38381.2 正标方管38381.5 正标方管38382.0 正标方管50500.7 正标方管50500.8 正标方管50500.9 正标方管50501.0 正标方管50501.2 正标方管50501.5 正标方管50502.0 正标方管50502.5 正标方管80801.2 正标方管名称20100.4 正标矩形管20100.5 正标矩形管20100.6 正标矩形管0612ZJ2010070612
45、ZJ2010080612ZJ2010090612ZJ2010100612ZJ2010120612ZJ2513040612ZJ2513050612ZJ2513060612ZJ2513070612ZJ2513080612ZJ2513090612ZJ2513100612ZJ2513120612ZJ3015050612ZJ3015060612ZJ3015070612ZJ3015080612ZJ3015090612ZJ3015100612ZJ3015120612ZJ3015150612ZJ3015200612ZJ3825050612ZJ3825060612ZJ3825070612ZJ3825080612
46、ZJ3825090612ZJ3825100612ZJ3825120612ZJ38251520100.7 正标矩形管20100.8 正标矩形管20100.9 正标矩形管20101.0 正标矩形管20101.2 正标矩形管25130.4 正标矩形管25130.5 正标矩形管25130.6 正标矩形管25130.7 正标矩形管25130.8 正标矩形管25130.9 正标矩形管25131.0 正标矩形管25131.2 正标矩形管30150.5 正标矩形管30150.6 正标矩形管30150.7 正标矩形管30150.8 正标矩形管30150.9 正标矩形管30151.0 正标矩形管30151.2 正
47、标矩形管30151.5 正标矩形管30152.0 正标矩形管38250.5 正标矩形管38250.6 正标矩形管38250.7 正标矩形管38250.8 正标矩形管38250.9 正标矩形管38251.0 正标矩形管38251.2 正标矩形管38251.5 正标矩形管0612ZJ5025070612ZJ5025080612ZJ5025090612ZJ5025100612ZJ5025120612ZJ5025150612ZJ5025200612ZJ6030080612ZJ6030090612ZJ6030100612ZJ6030120612ZJ6030150612ZJ6040120612ZJ7545
48、080612ZJ7545090612ZJ7545100612ZJ7545120612ZJ7545150612ZJ7545200612ZJ9545100612ZJ9545120612ZJ954515.正标花管编号0613ZH1904080613ZH1904090613ZH1904100613ZH1904110613ZH19041250250.7 正标矩形管50250.8 正标矩形管50250.9 正标矩形管50251.0 正标矩形管50251.2 正标矩形管50251.5 正标矩形管50252.0 正标矩形管60300.8 正标矩形管60300.9 正标矩形管60301.0 正标矩形管60301
49、.2 正标矩形管60301.5 正标矩形管60401.2 正标矩形管75450.8 正标矩形管75450.9 正标矩形管75451.0 正标矩形管75451.2 正标矩形管75451.5 正标矩形管75452.0 正标矩形管95451.0 正标矩形管95451.2 正标矩形管95451.5 正标矩形管名称190.48 正标花管190.49 正标花管190.410 正标花管190.411 正标花管190.412 正标花管0613ZH1904130613ZH1904140613ZH1904200613ZH1905100613ZH1905110613ZH1905120613ZH1905130613Z
50、H1905140613ZH1905200613ZH1906100613ZH1906110613ZH1906120613ZH1906130613ZH1906140613ZH1906200613ZH1907100613ZH1907120613ZH1907200613ZH1908100613ZH1908120613ZH1910080613ZH1910090613ZH1910120613ZH2204080613ZH2204100613ZH2204110613ZH2204120613ZH2204140613ZH2204200613ZH220510190.413 正标花管190.414 正标花管190.4