1、Industrial Measurement and Control Process Instrument Explorer Configuration Software User Manual 51-52-25-131 March 2006名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 1 页,共 34 页 - - - - - - - - - 03/06 Process Instrument Explorer Configuration Software User Manual i

2、i Notices and Trademarks Copyright 2006 by Honeywell Revision 7 March 2006 WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell d

3、uring the period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is Buyers sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. Specifications may

4、change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine

5、 the suitability of the product in the application. Industrial Measurement and Control Honeywell 1100 Virginia Drive Fort Washington, PA 19034 Process Instrument Explorer is a U.S. registered trademark of Honeywell Other brand or product names are trademarks of their respective owners. 名师资料总结 - - -精

6、品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 2 页,共 34 页 - - - - - - - - - 03/06 Process Instrument Explorer Configuration Software User Manual iii About This Document Abstract This document provides descriptions and procedures for the installation and operation of Process Instr

7、ument Explorer software. Contacts World Wide Web The following lists Honeywells World Wide Web sites that will be of interest to our customers. Honeywell Organization WWW Address (URL) Corporate http:/ Industrial Measurement and Control http:/ Telephone Contact us by telephone at the numbers listed

8、below. Organization Phone Number United States and Canada Honeywell 1-800-423-9883 Tech. Support 1-800-525-7439 Service 名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 3 页,共 34 页 - - - - - - - - - iv Process Instrument Explorer Configuration Software User Manual 03/06

9、 Contents 1INTRODUCTION.11.1Overview.11.1.1Features.12INSTALLATION.32.1System Requirements.32.2Install/Upgrade Procedure.42.3Uninstall Procedure.63OPERATIONS.73.1Overview.73.1.1Communications Setup.103.1.2Upload.113.1.3Offline Configuration.123.1.4Download.133.1.5Online Configuration.143.1.6Maintena

10、nce Data.153.1.7Infrared checklist.163.1.8Ethernet Q&A.174SERVICES.184.1Overview.184.1.1Pocket PC Services Menu.184.1.2PC Services Menu.184.2Export Configuration (PC only).204.3Transfer Configuration.204.4Manage Configuration Files .214.5Install Descriptive File (PC only).214.6Transfer Descriptive F

11、ile (PC only).224.7Transfer Healthwatch Data (Pocket PC only, UDC3500 only).224.8Enable Descriptive Name Support.224.9Import Database.234.10Export Database.245INDEX.256SALES AND SERVICE.26名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 4 页,共 34 页 - - - - - - - - - 03/

12、06 Process Instrument Explorer Configuration Software User Manual v Tables Table 3-1 Operations Icons _ 8Table 3-2 Operations Menu_ 9Table 4-1 Service menu_ 19名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 5 页,共 34 页 - - - - - - - - - vi Process Instrument Explorer C

13、onfiguration Software User Manual 03/06 Figures Figure 1-1 Screen capture of Process Instrument Explorer running on a Pocket PC _ 1名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 6 页,共 34 页 - - - - - - - - - Introduction 03/06 Process Instrument Explorer Configuration

14、 Software User Manual 1 1 Introduction 1.1 Overview Process Instrument Explorer (P.I.E.) lets you configure Honeywell process instruments such as controllers and analyzers using a PC (desktop/laptop) or Pocket PC. Figure 1-1 Screen capture of Process Instrument Explorer running on a Pocket PC 1.1.1

15、Features ?Create/edit configurations live, just connect software to controller comm port. ?Create/edit configurations offline and download later to controller comm port. ?Communication types available on process instruments: Infrared RS 485 Ethernet ?Common look and feel between PC and Pocket PC ver

16、sions. ?Same communications types on process instruments allow interconnectivity. ?Available in English, Spanish, Italian, German and French. 名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 7 页,共 34 页 - - - - - - - - - Introduction 2 Process Instrument Explorer Config

17、uration Software User Manual 03/06 ?The infrared connection provides a non-intrusive wireless connection with the instrument and maintains NEMA4X AND IP66 integrity. ?No need to get access to the back of the instrument to communicate with the instrument, no need to take your screw driver to wire the

18、 communication cable, no wiring mistake possible. You can now duplicate an instruments configuration, upload or download a new configuration in a matter of seconds, just by pointing your Pocket PC in the direction of the instrument. It takes just a few seconds to upload a configuration from an instr

19、ument. You can then save the configuration file onto your PC or pocket PC for review, modification or archiving. Furthermore, this software also gives you important maintenance information on the instrument: instantly get information on the current operating parameters, digital inputs and alarm stat

20、us, identify internal or analog input problems. 名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 8 页,共 34 页 - - - - - - - - - Installation 03/06 Process Instrument Explorer Configuration Software User Manual 3 2 Installation 2.1 System Requirements Hardware PC CPU: Int

21、el x86 processor RAM: 32MB Disk space: 4.2MB For IR Communications: Actisys ACT-IR220L+ http:/ For RS-485 Communications: Technman PC5001 or equivalent RS-232/485 Converter http:/ For Ethernet Communications: 10 BaseT or 10/100 BaseT Port Pocket PC CPU: Intel PXA250/ PXA255 or later RAM: 32MB Pocket

22、 PC must have an Infrared Port or an RS485 converter Software PC Windows 2000 SP2, Windows XP SP1, Windows NT SP6 Pocket PC Pocket PC 2002 or later Microsoft Active Sync application must be installed for the PC to communicate with the Pocket PC through the Active Sync cable. 名师资料总结 - - -精品资料欢迎下载 - -

23、 - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 9 页,共 34 页 - - - - - - - - - Installation 4 Process Instrument Explorer Configuration Software User Manual 03/06 2.2 Install/Upgrade Procedure Follow this procedure to install, reinstall, or upgrade P.I.E. ATTENTION: If upgrading, any P.I.E. da

24、tabases (that is, saved instrument configurations) can be copied to the new P.I.E. application directory. Older databases are compatible with newer versions of P.I.E. Step Action 1 If upgrading PocketPC, perform section 2.3 Uninstall Procedure before continuing. Insert P.I.E. CD into your PC. Click

25、“Install/Uninstall” from the opening menu.2 Welcome Screen starts off the installation.3 License agreement details the agreement on which you purchased this software. Continue only after reading and agreeing to these terms. 4 Select Platform Select the platform on which to install P.I.E.: PC, Pocket

26、 PC, or Both. 5 Select Version This screen appears only if P.I.E. is already installed. Use this screen to reinstall or upgrade your software. If no version is already installed then this screen does not appear; go to Step 6.To reinstall: The upper frame shows the version of the software that can be

27、 installed; click Install to reinstall the version specified. To upgrade: The lower frame shows the versions and their languages that are installed. Select a version/languages to be upgraded with the version in the upper frame, then select Upgrade. Attention: Any P.I.E. databases (that is, saved ins

28、trument configurations) can be copied. Older databases are compatible with newer versions of P.I.E. 6 PC installation: Enter User Name, Serial Number, and License Key Enter user name. Enter serial number and license key from the CD cover. Note: numbers are case-sensitive. Pocket PC installation: Mic

29、rosoft Active Sync application must be installed on the PC and Pocket PC. Connect the Pocket PC to the PC with an Active Sync Cable. Power up Pocket PC. On PC select the Active Sync “Guest Partnership” type connection. Enter User Name, Serial Number, and License Key Enter user name. Enter serial num

30、ber and license key from the CD cover. Note: characters are case-sensitive. 名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 10 页,共 34 页 - - - - - - - - - Installation 03/06 Process Instrument Explorer Configuration Software User Manual 5 Step Action 7 Select Language(

31、s) Select one or more languages to install. If installing to both the PC and the Pocket PC then the software will be first installed in the Pocket PC and then in the PC. 8 Choose Destination Select a path in which to install the software. Use the default path shown or browse to a different path. Thi

32、s screen does not appear if reinstalling over existing version.Note: Pocket PC devices do not have drives, so the destination folder should not contain drive information. Pocket PC destination folder must start with a “ ”. 9 Select Databases to Copy This screen appears only if you previously uninsta

33、lled a version and retained the database. (A P.I.E. database contains saved instrument configurations.) If no databases were retained this screen does not appear, go to Step 10. You are shown a list of versions that are currently installed, as well as previously retained databases that have been fou

34、nd. You are asked to select the database version you want to copy into the newly installed/upgraded version of P.I.E.10 Finalize installation PC: Shortcut(s) can be installed in the Start Menu of the PC. Shortcuts are named “PIE(language)(version)”. For example, “PIEEng1_00” is PIE English 1.00. Poc

35、ket PC: A popup announces that files are being transferred to the Pocket PC. A second popup announces that setup is accessing the mobile device. The Files will be copied to the directory selected in step 8. When the installation finishes, a message box reminds you to check your Pocket PC screen to s

36、ee if additional steps are necessary to complete the installation. If all is ok the Pocket PC tells you the installation is complete. If your PocketPC has Windows Mobile 5.0 operating system, a popup will indicate that the software is from an unknown source. Click yes to proceed with the installatio

37、n. Shortcut(s) will be installed in the Start Menu or Program Group of the Pocket PC. Shortcuts are named “PIE(language)(version)”. For example, “PIEEng1_00” is PIE English 1.00.11 Installation/upgrade is finished. 名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 11 页,

38、共 34 页 - - - - - - - - - Installation 6 Process Instrument Explorer Configuration Software User Manual 03/06 2.3 Uninstall Procedure Follow this procedure to uninstall P.I.E. from your PC or Pocket PC. ATTENTION: You must uninstall older versions from your PocketPC before doing an upgrade. Step Acti

39、on 1 Insert P.I.E. CD into your PC. Click “Install/Uninstall” from the opening menu.2 Welcome Screen starts off the procedure.3 License agreement details the agreement on which you purchased this software. Continue only after reading and agreeing to these terms. 4 Select Platform Select the platform

40、 from which to uninstall P.I.E.: PC, Pocket PC, or Both. 5 Select Version The upper frame shows the version of the software that can be installed or upgraded to; leave as is and go to lower frame. The lower frame shows the versions and their languages that are installed. Select a version/languages t

41、o uninstall, then select Uninstall. Retain Database? If any instrument configurations (that is, a P.I.E. database) exist on your PC or Pocket PC then a popup appears asking if you want to retain the database. When given the option to retain database: Select Yes to save the database for future use if

42、: you will install P.I.E. later, or you are upgrading your PocketPC with a newer version, or you want to archive the database. The database location is then shown. Or Select “No” to delete the database. 6 Uninstallation is finished. 名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - -

43、 - - - - - 第 12 页,共 34 页 - - - - - - - - - Operations 03/06 Process Instrument Explorer Configuration Software User Manual 7 3 Operations 3.1 Overview The PC and Pocket PC Operations are virtually identical. Any differences will be indicated. Operations choices are: Communications Setup Before uploa

44、ding or downloading instrument configurations you must set up communications. Upload DatabaseUploads instrument configuration to PC/Pocket PC. Offline ConfigurationEdits an instrument configuration for later downloading. DownloadDownloads an instrument configuration to an instrument. Online Configur

45、ation Edits and downloads one instrument setting at a time. Maintenance Data Displays key operating parameters and status parameters of the instrument without switching between the instrument screens. Some of the information presented here is not visible through the instrument display panel. Used pr

46、imarily for diagnostics. The Operations features are accessed using icons (Table 3-1) or the Menu (Table 3-2). 名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 13 页,共 34 页 - - - - - - - - - Operations 8 Process Instrument Explorer Configuration Software User Manual 03/

47、06 Table 3-1 Operations Icons PC Pocket PC 名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 14 页,共 34 页 - - - - - - - - - Operations 03/06 Process Instrument Explorer Configuration Software User Manual 9 Table 3-2 Operations Menu PC (click Operations) Pocket PC (tap Me

48、nu/Operations) 名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 15 页,共 34 页 - - - - - - - - - Operations 10 Process Instrument Explorer Configuration Software User Manual 03/06 3.1.1 Communications Setup Before transferring data between P.I.E. and instrument you must s

49、et up your PC or Pocket PC communication parameters using this procedure. Step Action 1 Select “Communication Setup” or “PC Comm Setup” icon or menu item. 2 Select “Communication type” to be used with the process instrument: Infrared, RS485, or Ethernet. The status bar at the bottom of the screen in

50、dicates your choice. Note 1: Ethernet feature is not supported in Pocket PC. Note 2: IPAQ Pocket PCs do not support serial communication. 3 “Select Type to set up” Infrared: Device address: Enter address of the process instrument. Default 3. Serial Port (PC only): Your PC requires an Infrared cable