1、精品资料E-Prime常见错误代码表.Table of Common ErrorsThe following table lists commonly encountered errors, a description of the error, and possible solutions to eliminate the error. A complete listing of errors may be found in the Reference Guide Appendix A - Error List.NumberDisplayed MessageError Description
2、Solution10000The allowable response was unrecognized: The value entered in the Allowable field in the Response Options (Duration/Input Property Page) is not recognized by the input mask.Enter device specific values for allowable response.10001The allowable response cannot be emptyThe Allowable field
3、 in Response Options (Duration/Input Property Page) must contain a value when input is enabled.Enter device specific values for allowable response.10002Cannot have duplicate responseA single value has been entered more than once.Since the Allowable field in the Response Options (Duration/Input Prope
4、rty Page) represents a mask of values, entering duplicate values would be redundant.Verify that unique entries are entered only once10017Invalid Termination ResponseThe value entered in the Termination Response field in the Advanced Response Options (Duration/Input Property Page) is not recognized b
5、y the input mask.Enter device specific value for the termination response10018Correct Response is not part of AllowableThe value entered in the Correct Response field in the Response Options (Duration/Input Property Page) is not included as part of the Allowable Response OptionsSpecify a value that
6、is included as part of the Allowable Response.10019Termination Response is not part of AllowableThe value entered in the Termination Response field in the Advanced Response Options (Duration/Input Property Page) is not included as part of the Allowable Response OptionsSpecify a value that is include
7、d as part of the Allowable Response10044The name cannot be longer than 80 characters!An object was named in the interface with a length of more than 80 characters. An object name can only contain A-Z, a-z, 0-9, must begin with an alphabetic character, must not contain more than 80 characters, and mu
8、st be unique within the systemEnter a valid name through the Properties window, Procedure time line, or Structure view windows that does not have more than 80 characters.10046Name contains an invalid characterAn object was named in the interface with a value that contains an invalid character. E-Obj
9、ect names are generated to E-Basic script, which does not permit variable names to have invalid characters. An object name can only contain A-Z, a-z, 0-9Enter a valid name through the Properties window, Procedure timeline, or Structure view window that does not have any invalid characters.18005Canno
10、t load sound file . An error occurred while attempting to load a sound file. This can be due to file not found, file already open, lack of resources, invalid configuration, or improper driver.Ensure that the configuration of the file matches the configuration of the sound device, that the file is no
11、t already open, and that the filename and path are valid18010The value for MaxLength is invalidThe MaxLength field of the Sound object (General property page) represents a value that is not valid. Valid values for MaxLength cannot be less than 100Set the value of MaxLength to a value no less than 10
12、0.18011The value for BitsPerSample is invalidThe BitsPerSample field of the Sound device (Experiment Object; Devices tab) represents a value that is not valid. Common values are 8 and 16, but the settings are hardware dependent.Set the value of BitsPerSample to 8 or 16 to match the format of the WAV
13、 file. All files must be saved using the same format.18012The value for Channels is invalidThe Channels field of the Sound device (Experiment Object; Devices tab) represents a value that is not valid. Valid values are 1 for mono and 2 for stereo.Set the value of Channels to 1 or 2 to match the forma
14、t of the WAV file. All files must be saved using the same format18013The value for SamplesPerSecond is invalidThe SamplePerSecond field of the Sound device (Experiment Object; Devices tab) represents a value that is not valid. Common values are 11025, 22050,44100, but settings are hardware dependent.Set the value of SamplesPerSecond to 11025, 22050, or 44100 to match the format of the WAV file. All files must be saved using the same format