《2022年通过HMC升级微码 .pdf》由会员分享,可在线阅读,更多相关《2022年通过HMC升级微码 .pdf(28页珍藏版)》请在taowenge.com淘文阁网|工程机械CAD图纸|机械工程制图|CAD装配图下载|SolidWorks_CaTia_CAD_UG_PROE_设计图分享下载上搜索。
1、Upgrade and Update IBM p5 System Firmware with HMC名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 1 页,共 28 页 - - - - - - - - - Upgrade and Update IBM p5 System Firmware with HMC2Document Revision HistoryVersionDate/TimeAuthor/EditorCommentsV1.0March 19th, 2008Hank Cen
2、Initial Version of DocumentV1.0.1April 10th, 2008Hank CenCorrected errors and typos? 2008 by HankCAll rights reserved.No part of this publication may be reproduced or transmitted in anyform or by any means, electronic or mechanical including photography, recording or any information storage or retri
3、eval system without permission in writing from the publisher.名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 2 页,共 28 页 - - - - - - - - - Upgrade and Update IBM p5 System Firmware with HMC3Table of Contents1UPGRADE P5 SYSTEM FIRMWARE WITH HMC.52UPDATE P5 SYSTEM FIRMWA
4、RE WITH HMC.17名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 3 页,共 28 页 - - - - - - - - - Upgrade and Update IBM p5 System Firmware with HMC4Conventions Used in this DocumentConventionDescriptiontextItalicized text is used to emphasize a word or present new concepts.
5、boldBolded text indicates user input in examples.Brackets indicate that the enclosed item is optional.A horizontal ellipsis indicates that you can repeat the preceding items one or more times.$ DSN ITS.A vertical ellipsis in an example indicates that not all lines are shown.$ COPY$ RENAMEText exampl
6、es are enclosed in a box and appear in Courier New font, i.e., examples that do not portray a graphical user interface.Tools | Options | ViewThis is a compressed notation commonlyused in Windows examples. For example, “Choose the Tools pull-down menu, select the Options menu item and then click on V
7、iew. ”名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 4 页,共 28 页 - - - - - - - - - 1Upgrade p5 System Firmware with HMC名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 5 页,共 28 页 - - - - - - - - - Upgrade and Update IBM p5 System Firmwar
8、e with HMC6This document describes step by step on how to upgrade system firmware (microcode) on IBM p5 servers with HMC from either an FTP repository or a CD/DVD. In our example, theserver to receive the firmware upgrade is called p5server50, a p5 hardware, type 9110-510, S/N 10-4455E.This method o
9、f upgrading firmware can also be applied to multiple servers who have connections to the same HMC. We will point out the case of multiple server upgrades in the following steps accordingly.Pre-requisites:?To ensure the system firmware is applicable to the hardware type. In our example, all the machi
10、ne hardware type 9110-510, 9131-52A and 9133-55A are supported by system firmware 01SF240_320_201.?To ensure the HMC level meets the minimum requirement for the system firmware upgrade. In our example, the HMC level is 6.12 that meets the recommended HMC level. ?The p5 servers to receive the firmwar
11、e upgrade are connected to the HMC. In our example, the server p5server50 and others are connected to an HMCwhich is called p5-hmc.?In case of obtaining new firmware files from FTP repository, the System Firmware files have to be downloaded and placed in a directoryon a networked serverwhere the HMC
12、 is able to FTP in to and get the firmware filesfrom. In our example, the files for firmware 01SF240_320_201 are 01SF240_320_201.rpm and 01SF240_320_201.xml. Theyare storedin directory /opt/ccfw/data on a networked server called nimserver. ?In case of obtaining new firmware files from a CD/DVD, the
13、CD/DVD contains the new firmware files has to be placed in the HMCs DVD drive. In our example, a DVD is cut with image sysimage.iso which contains System Firmware 01SF240_320_201.?A valid uid to access directory /opt/ccfw/data on nimserverthrough FTP.Firmware update procedure:1.If you choose to obta
14、in new firmware from an FTP site, make sure the firmware files are in place. In our example, login to server nimserverwho contains new firmware files FTP accessto confirm the two files are in place; theyare 01SF240_320_201.rpm and 01SF240_320_201.xml. $ cd /opt/ccfw/data$ pwd/opt/ccfw/data$ ls -ltot
15、al 143928-rwxrwxrwx 1 abelo system 15129137 Jan 03 13:46 01SF240_320_201.rpm-rwxrwxrwx 1 abelo system 68757 Jan 03 13:46 01SF240_320_201.xml-rwxrwxrwx 1 abelo system 58490880 Jan 03 16:12 SF240_320_BP240_214.iso$名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 6 页,共 28
16、 页 - - - - - - - - - Upgrade and Update IBM p5 System Firmware with HMC72.To ensure the current firmware image level. Login to server p5server50to find out the current firmware image level, machine type and S/N. And to confirm it is the right machine to upgrade. $ uname -MuIBM,9110-510 IBM,10648455E
17、$ lsmcode -Arsys0!system:SF225_096 (t) SF225_096 (p) SF225_096 (t)ent0!14108902.DV0210ent1!14108902.DV0210sisscsia0!44415255.050A008acd0!IBM-RMBO002050.H106hdisk0!ST37330.53313233.4335304Bhdisk1!ST37330.53313233.4335304Bses0!00000000.7167$In case of multiple serversupgrades, login to each of the ser
18、vers ahead of time to collect information such as machine type and S/N. Write them down on a paper.p5server50 -IBM,9110-510 IBM,10648455Ep5server52 -IBM,9110-510 IBM,106485FBEp5server53 -IBM,9110-510 IBM,106485F4Ep5server54 -IBM,9110-510 IBM,106485F8Ep5server55 -IBM,9110-510 IBM,10648451Ep5server56
19、-IBM,9110-510 IBM,1064853AEp5server57 -IBM,9110-510 IBM,10648453Ep5server58 -IBM,9110-510 IBM,10648444Ep5server59 -IBM,9110-510 IBM,106485F0E3.In the HMC console to whom the server p5server50connects, under the HMCs name, expand Licensed Internal Code maintenance , then select Licensed Internal Code
20、 Updatesin the Navigation Area, then select Upgrade Licensed Internal Code toa new release.名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 7 页,共 28 页 - - - - - - - - - Upgrade and Update IBM p5 System Firmware with HMC84.In the Target Object Selectionbox, select the t
21、ype and S/N(s) that match your machines information collected above. Click on OK.In the case of upgrading firmware on multiple servers, hold down CTRL key and click on the machines to select multiple servers.名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 8 页,共 28 页 -
22、 - - - - - - - - Upgrade and Update IBM p5 System Firmware with HMC95.In Specify LIC Repositorybox, if you choose to obtain the firmware RPM files from an FTP site, select FTP site. Click on OK .If you choose to obtain the new firmware from a CD/DVD, select DVD drive . Click on OK and skip over the
23、next step.名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 9 页,共 28 页 - - - - - - - - - Upgrade and Update IBM p5 System Firmware with HMC106.If you have chosen the FTP site, in FTP Site Access Informationbox, fill in FTP site name, User ID and Password for access to t
24、he FTP site. Click on OK .7.In Select LIC Level box, high-light the firmware level (in this example is 01SF240_320) and click on OK .8.In Select power off option box, select Power off automatically (shortest overallupdate time) and click on OK .名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - -
25、- 名师精心整理 - - - - - - - 第 10 页,共 28 页 - - - - - - - - - Upgrade and Update IBM p5 System Firmware with HMC119.Click on Accept to accept the Hardware management Console License Agreement .名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 11 页,共 28 页 - - - - - - - - - Upgr
26、ade and Update IBM p5 System Firmware with HMC1210. Click on OK to confirm the action of upgrade of LicensedInternal Code.In the case of upgrading firmware on multiple servers, you will see the following confirmation screen.名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - -
27、- 第 12 页,共 28 页 - - - - - - - - - Upgrade and Update IBM p5 System Firmware with HMC1311. Click on OK to start install the new firmware. 12. The firmware upgrade is in progress It can take up to an hour to complete. Click on OK when the upgrade is complete and the OK button appears. 名师资料总结 - - -精品资料
28、欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 13 页,共 28 页 - - - - - - - - - Upgrade and Update IBM p5 System Firmware with HMC14In the case of upgrading firmware on multiple servers, you will see the following progress screen.名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - -
29、 名师精心整理 - - - - - - - 第 14 页,共 28 页 - - - - - - - - - Upgrade and Update IBM p5 System Firmware with HMC1513. Back in to HMC, select Server and Partition , then click on Server Management to ensure all the LPARs are in Running state. If not, then right-click on the LPAR, select Activate in the pop-u
30、p menu.14. Log back in to the server p5server50and other servers,run command lsmcode Ar to confirm the upgraded level. $ lsmcode -Arsys0!system:SF240_320 (t) SF240_320 (p) SF240_320 (t)ent0!14108902.DV0210ent1!14108902.DV0210sisscsia0!44415255.050A008acd0!IBM-RMBO002050.H106hdisk0!ST37330.53313233.4
31、335304Bhdisk1!ST37330.53313233.4335304Bses0!00000000.7167$15. Check on error report$ errpt | moreIDENTIFIER TIMESTAMP T C RESOURCE_NAME DESCRIPTIONA6DF45AA 0318145508 I O RMCdaemon The daemon is started.2BFA76F6 0318140708 T S SYSPROC SYSTEM SHUTDOWN BY USER9DBCFDEE 0318144208 T O errdemon ERROR LOG
32、GING TURNED ON192AC071 0318140608 T O errdemon ERROR LOGGING TURNED OFFBE0A03E5 0318140108 P H sysplanar0 ENVIRONMENTAL PROBLEM.16. If you logged in the servers through HMC, then you need to check network connectivity for those servers by at least PING-ing them.17. At this point the firmware upgrade
33、 has complete.名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 15 页,共 28 页 - - - - - - - - - Upgrade and Update IBM p5 System Firmware with HMC16名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 16 页,共 28 页 - - - - - - - - - Upgrade and Up
34、date IBM p5 System Firmware with HMC172Update p5 System Firmware with HMC名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 17 页,共 28 页 - - - - - - - - - Upgrade and Update IBM p5 System Firmware with HMC18This document describes step by step on how to update system firm
35、ware (microcode) on IBM p5 servers with HMC from either an FTP repository or a CD/DVD. In this example, theserver to receive firmware upgradeis called plutonium, a p5 hardware, type 9133-55A, S/N 06-2774H. Pre-requisites:?To ensure the system firmware is applicable to the hardware type. In our examp
36、le, all the machine hardware type 9110-510, 9131-52A and 9133-55A are supported by system firmware 01SF240_320_201.?To ensurethe HMC level meets the minimum requirement for the system firmware upgrade. In our example, the HMC level is 6.12 which meets the recommended HMC level. ?The p5 servers to re
37、ceive the firmware upgrade are connected to the HMC. In our example, the server plutonium is connected to an HMC called hmc03.?In case of obtaining new firmware files from FTP repository, the System Firmware files have to be downloaded and placed in a directoryon a networked server to where the HMC
38、is able to FTP in and get the firmware files. In our example, the files for firmware 01SF240_320_201 are 01SF240_320_201.rpm and 01SF240_320_201.xml. Theyare located in directory/opt/ccfw/data on a networked server called nimserver.?In case of obtaining new firmware files from a CD/DVD, the CD/DVD c
39、ontains the new firmware files has to be placed in the HMCs DVD drive. In our example, a DVD is cut with image sysimage.iso which contains System Firmware 01SF240_320_201.?A valid uid to access directory /opt/ccfw/data on nimserverthrough FTP.Firmware update procedure:1.If you choose to obtain new f
40、irmware from FTP site, make sure the firmware files are in place. In our example, login to server nimserver who contains new firmware files FTP access to confirm the two files are in place; theyare 01SF240_320_201.rpm and 01SF240_320_201.xml. $ cd /opt/ccfw/data$ pwd/opt/ccfw/data$ ls -ltotal 143928
41、-rwxrwxrwx 1 abelo system 15129137 Jan 03 13:46 01SF240_320_201.rpm-rwxrwxrwx 1 abelo system 68757 Jan 03 13:46 01SF240_320_201.xml-rwxrwxrwx 1 abelo system 58490880 Jan 03 16:12 SF240_320_BP240_214.iso$名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 18 页,共 28 页 - - -
42、 - - - - - - Upgrade and Update IBM p5 System Firmware with HMC192.Ensure the current firmware image level. Login to server plutonium to find out the current firmware image level, machine type and S/N. And to confirm it is the right machine to upgrade. $ uname -MuIBM,9133-55A IBM,20683874H$ lsmcode
43、-Arsys0!system:SF240_298 (t) SF240_298 (p) SF240_298 (t)fcs0!df1000fa.191105sisscsia0!44415255.050A008afcs1!df1000fa.191105cd0!IBM-RMBO002055.1.72hdisk0!ST37330.4A523030.43373046hdisk1!ST37330.4A523030.43373046ent0!14108902.DV0210ent1!14108902.DV0210$3.In HMC console, under the HMCs name, expand Lic
44、ensed Internal Code maintenance , then select Licensed Internal Code Updatesin the Navigation Area, then select Change Licensed Internal Code for the current release .名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 19 页,共 28 页 - - - - - - - - - Upgrade and Update IBM
45、p5 System Firmware with HMC204.In Target Object Selectionbox, select the type and S/N(s) that match your machines information collected above. Click on OK .5.In Change Licensed Internal Codebox, select Start Change Licensed Internal Code wizard. Click on OK .6.In Specify LIC Repositorybox, if you ch
46、oose to obtain the firmware RPM files from a FTP site, select FTPsite. Click on OK .名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 20 页,共 28 页 - - - - - - - - - Upgrade and Update IBM p5 System Firmware with HMC21If you choose to obtain the new firmware from a CD/DVD
47、, select DVD drive . Click on OK and skip over thenext step.7.In FTP Site Access Informationbox, fill in FTP site, User ID , and Password. Click on OK .8.In Change Licensed Internal Code Wizardbox, click on Next.9.In Change Licensed Internal Code Wizard box, click on Advanced Options button.名师资料总结 -
48、 - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 21 页,共 28 页 - - - - - - - - - Upgrade and Update IBM p5 System Firmware with HMC2210. In Managed System and Power Licensed Internal Code (LIC) Concurrency box, select the machine to update, in this example is 9133-55A*683874H. C
49、lick on View Information button11. In Managed System and Power Licensed Internal Code (LIC) Level Detailsbox, confirm the current release level and the level to update to. Click on Close. If you update multiple machines, do this to each of them.名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - -
50、- 名师精心整理 - - - - - - - 第 22 页,共 28 页 - - - - - - - - - Upgrade and Update IBM p5 System Firmware with HMC2312. Returned backin Managed System and Power Licensed Internal Code (LIC) Concurrency box, Click on OK .13. Returned back in Change Licensed Internal Code Wizardbox, click on Next.名师资料总结 - - -精