《光缆开盘测试报告(共2页).doc》由会员分享,可在线阅读,更多相关《光缆开盘测试报告(共2页).doc(2页珍藏版)》请在taowenge.com淘文阁网|工程机械CAD图纸|机械工程制图|CAD装配图下载|SolidWorks_CaTia_CAD_UG_PROE_设计图分享下载上搜索。
1、精选优质文档-倾情为你奉上附件二 16-A13858 光缆盘开盘测试报告测试人员:测试时间:2016-11-10测试仪表:测试波长:1310 nm、1550nm光缆架设线路光缆型号光缆长度(KM)光缆芯数(剩余/总共)光缆生产厂家地埋管ADSS-PE-24B1.3-300M0.524江苏藤仓科技股份有限公司松套管色线或代号光纤色标光纤衰减实测结果(dB/Km)备注松套管序号松套管色标1310 nm1550nm1蓝/蓝0.360.251蓝/橙0.360.251蓝/绿0.360.251蓝/棕0.360.251蓝/灰0.360.251蓝/白0.360.252橙/蓝0.360.252橙/橙0.360.
2、252橙/绿0.360.252橙/棕0.360.252橙/灰0.360.252橙/白0.360.253绿/蓝0.360.253绿/橙0.360.253绿/绿0.360.253绿/棕0.360.253绿/灰0.360.253绿/白0.360.254棕/蓝0.360.254棕/橙0.360.254棕/绿0.360.254棕/棕0.360.254棕/灰0.360.254棕/白0.360.25 16-A13891 光缆盘开盘测试报告测试人员:测试时间:2016-11-10测试仪表:测试波长:1310 nm、1550nm光缆架设线路光缆型号光缆长度(KM)光缆芯数(剩余/总共)光缆生产厂家10kV双河线
3、ADSS-PE-24B1.3-300M11.524江苏藤仓科技股份有限公司松套管色线或代号光纤色标光纤衰减实测结果(dB/Km)备注松套管序号松套管色标1310 nm1550nm1蓝/蓝0.3310.1891蓝/橙0.3310.1891蓝/绿0.3310.1891蓝/棕0.3310.1891蓝/灰0.3310.1891蓝/白0.3310.1892橙/蓝0.3310.1892橙/橙0.3310.1892橙/绿0.3310.1892橙/棕0.3310.1892橙/灰0.3310.1892橙/白0.3310.1893绿/蓝0.3310.1893绿/橙0.3310.1893绿/绿0.3310.1893绿/棕0.3310.1893绿/灰0.3310.1893绿/白0.3310.1894棕/蓝0.3310.1894棕/橙0.3310.1894棕/绿0.3310.1894棕/棕0.3310.1894棕/灰0.3310.1894棕/白0.3310.189专心-专注-专业