《kv区域性降压变电所一次系统设计外文翻译 .docx》由会员分享,可在线阅读,更多相关《kv区域性降压变电所一次系统设计外文翻译 .docx(8页珍藏版)》请在taowenge.com淘文阁网|工程机械CAD图纸|机械工程制图|CAD装配图下载|SolidWorks_CaTia_CAD_UG_PROE_设计图分享下载上搜索。
1、精品名师归纳总结110 kV substations digital transformation case analysisAbstractThis paper brieflyintroduces the basic concept ofdigitalsubstation, Analysisedsubstation digitizationreconstruction examples based on110kVsubstationsA.detailed analysised ofthe substation secondary equipmentsuch aschanges in oper
2、ating mode.Digital Substation discussed possible options for reform, and according to the results of the operation of digital substation work out countermeasures and Recommended.Key words digital substation。 automation。 Electronic TransformerWith automation and computer network traffic monitoring an
3、d protection technology, the rapid development in Past two decadeshas made substantial progress has been achieved for the digital substation automation system . Network laid the technical foundationforfulfillingthe other hand, withthe special high-voltagelarge- capacity .The gradual formation of lar
4、ge scale grid, the grid stable and reliable control of the safety information exchange , And put forward higher requirements of the urgent. Digital Substation substation construction will be Trends .1. the characteristics of digital substationThe basic features of digital substation can be summarize
5、d as: intelligent primary equipment, secondary equipment network, automated operation and management system. Since the station relative toconventional integrated, digitalsubstation equipment,theprotectiveprinciple,theinternalalgorithm,logichasnot fundamentally changed, but in sampling digital, netwo
6、rked communication medium, communication interface standardization brought changes to improve the reliability ofsubstation automation system. Reliability of information transmission can be achieved。 secondary wiring is simple。 measurement accuracy。 share unified information platform, reduce duplicat
7、ion of equipment 。 easy functionality expansion。 management automation.2. 110 kV Substation rehabilitation programs1 a part of. 110kV single busbar sub-main wiring methods, 110kV line 3 times, with a standby power source。 the main volume into 2 sets of 3 variables 。 35kV main connection method for t
8、he Single Bus, 35kV line 5 back。 10kV main connection is a single busbar way, 2 sets of capacitors, 10kV line 18 back, 2 sets of ground change,the replacement oftransformers forthe electronic, installationofPT parallel combiner。 replacement in situ terminal box, installation switches intelligent uni
9、t, to achieve local control switch 。 configuration integrated digital protection monitoring devices and digital power meter, equipped with digital standby power source device,care monitoring devices and focus group screen interval of combiner.2 station control layer. Station control layer consists o
10、f a units monitoring host, 2 Machines GPS communications management component to form the station control level star network, monitoringthe host machine automatically selects the host communication management, communication management unit and the interval as an independent link layer device, and th
11、e bay level devices communication, accessto remote, telemetry data, only the host with the remote authority, communication management unit interval of five anti-blocking cross-sequence and function of small可编辑资料 - - - 欢迎下载精品名师归纳总结current grounding line, for the interval layer and process layer devic
12、e when the hard right.3 spacer. Interval layer is the core of the station automation, communications related to the implementation of the process level GOOSE 35kV, 10kV lines, capacitors, ground change, sub-protective and monitoringlocal installation 。 110kV Main Transformer Protection and Control f
13、ocus group back screen, installed in the control Room, located optical interface screen, providing the distance to the control room of the optical conversion interface。 three sides of the main transformer backup protection one, 110kV segmentation and one prepared from the cast。 monitoring interface
14、communication, lockout protection association。 private GOOSE network to achieve important, the key trip control, station control layer GOOSEnetwork, to achieve control of auxiliary tripping minor, such as the low cycle load shedding.4 the process level. Parallel combination provides voltage voltage,
15、 the output interval of combiner to provide the voltage signal。 the main transformer and back of each side of the differential transformer is divided into, setting separatecombiner, combiner transformer transformer protection group in the main screen。 110kV line segment combiner configured individua
16、lly, group within the control room screen line combiner。 35kV 10kV PT 1 set of each combiner configured to achieve PT parallel functions。 arranged in the sub-cabinet。 35kV 10kV part of the accessby small- signal combiner, arranged in switch cabinet.5 communication network. a. station control station
17、 control interlayer layer network layer network: set a switch, the Internet communications management unit monitoring host dual GPS。 interval layer network: at 10kV I Section II Section were placed on a switch, 35kV put a switch in paragraph , the main cabinet to set up a communications switch, focu
18、s group screen spacer device to the communications network of the main cabinet b. the process level,GOOSE private network.Process layer network: electronic transformer CT interval of combiner access, electronic access to the voltage transformer PT merger, voltage output access interval of combiner c
19、ombiner 。GOOSE Network: ringnetwork composed of 1 # Main Variable interval Protection and Control and smart cell group into a RSG2100, 2 # Main Transformer Protection and Control and intelligence unit interval group into another RSG2100, 110kV lineinterval of Protection and Control and intelligence
20、unit set into another RSG2100,composed of a single inter-switch interconnect ring.6 After the transformation of the substation has the advantage. a. back-office system integration, are in compliance with requirements of the secondary consolidation。 b. with 61850 protocol, consistency, and simple int
21、erface without a lot of signalcable installation and commissioning work is small, can reduce the cost of maintenance and renovation。 c. use of electronic CT / PT, non-core, eliminating the magneticsaturation。 to avoid the CT open circuit,earth fault inthe secondary circuitproblems。 d. long-distance
22、transmission of digital signals using optical fiber, anti- interference ability, reducing the transmission error。 of nearly still use the hard- wiring from the transmission, reducing the number of devices to simplify structure.3. substations protection equipment remote monitoring and management syst
23、ems analysis and design可编辑资料 - - - 欢迎下载精品名师归纳总结1 substation protection equipment remote monitoring and management system The system for power companies to protect managements application requirementsdesigned to protect the department aims to provide a management and maintenance of station equipment
24、platform, the system should meet the following features: timely, accurate collection of station equipment, real-time information。 accurate monitoringof all setting relay station changes, and timely warning。 comprehensive managementof all the relay stations recorded dat。aprovides engineers easy acces
25、s to any virtualchannels to all relay stations。 provide a friendly user interface for maintenance and可编辑资料 - - - 欢迎下载精品名师归纳总结managemen。tAccurate and fast data retrieval and quer。yhigh level of security,可编辑资料 - - - 欢迎下载精品名师归纳总结strict management of operating authority and provides audit functio。n high
26、 scalability, maintainability 。 system is stable, safe and reliabl。esystem has a good man-可编辑资料 - - - 欢迎下载精品名师归纳总结machine interface According to the actual needs of the application of the hierarchicalprinciple and open systems, the whole system is divided into enterprise application layer, service l
27、ayer, station control management and equipment level.Station control stations relay data subsystem is responsible for the collection, processing, valuation and management functions include the following modules: RTDB: RealTime Database, real-time data management, systems management as the core of th
28、e system responsible for managing all of the real time data, events, police records。 HMI: HumanMachine Interface, local display and control managemen。t DCAl03: DataCollectionApplicationwithIECl03, IECl03 communications processing, complete with support IECl03 relay communications between the Statute
29、, to collectreal-time data sent to relay real-time databas。e as Support 103 for the relay settingand recorded data, the corresponding value for manageme。nt Courier: CourierDCA communications processing, complete with relay communication between the relayreal-time data collection, event data, protect
30、ion setting , recorded da。ta Modbus:ModbusDCA Statute of the communication processing。 DNP30: DNP3.0 DCAStatute of the data processin。g GD8Calc: GD8-line basis, to provide advancedautomatic calculation and automatic control functions。 VC: Virtual Connection Manager, providing a virtual channel with
31、the server connection and, if necessary,send a request to the DCA loan communication chann。el DNPDPA: DPADataProces sApplication type applications, communicate with the server through DNP3.0 statute.This subsystem is responsible for the data collection points, and saved to the server SQLServer datab
32、ase, including the following modules: DC: DataCollection application station control subsystem is responsible for communication and exchange through the DNP3 0 real-time data and event data, and to the real-time da。ta RTDB: real-time data management, including real-time data management, and a variet
33、y of real-time data access interface shared memory TCP IP database, and save thehistorical database, to provide lock contro。luser management: Manage user roles,password, operating privilege, etc。.role management, managerial role and define theappropriate authority。 configuration management: manageme
34、nt station data and communication within the parameters and alarm configuration SMS GSM EMAIL 。 graphics production system: user-defined interface production syste。mvirtual serial port, virtual channel dynamic managemen。tevent query Modules:可编辑资料 - - - 欢迎下载精品名师归纳总结Alarm query module, the station dat
35、a query module: check the communication relay stations within the state of constant change state, recorded da。taconstant query module。 Virtual Connect modules。 single line diagram: a graphical user interface可编辑资料 - - - 欢迎下载精品名师归纳总结provides real-time data Display operation control, etc。.module。 opera
36、tional records check. 2 database design systemhistorical data query。 audit可编辑资料 - - - 欢迎下载精品名师归纳总结Monitoring and management system for the protection of the core is around thestation designed to protect the information data, the database design directly related to the effect and operation of the who
37、le system performance, while the database system to other computer systems, with more objects, longer survival data, with high requirements on the maintenance and security of the information related to such issues, so the database design must be carefully and cautiously database design for this syst
38、em, we propose the following four basic principle to guide the design of the database :a, try to ensure the simplicity of the database, including: simple database structure,data sheets and data sheet design simple relationship between Q and other simple b, to ensure the integrity of database systems
39、, including: the physical integrity of the database system, database, logical integrity, the integrity of the elements of the database systemc, to ensure the confidentiality of the database system, including: the database system, the user identity and authority to identify, to ensure that each user
40、and their access to the system is legitimate and can be identified in the design of the time so we can the body of the user identification and access rights to control the system provides the user can only operate within the purview and ensure the security of system datad, to ensure the availability
41、 of database systems, which ensure that the database can access system resources, easy to use and to avoid data conflicts in the data access process, to ensure no conflict between the data and contradictions in this system, the server database used relational database, and use Microsofts SQL2005Serv
42、er name of the database design is MinilPACS, stored data are historical data configuration information and event information data, user information configuration data using MS Acces s database, download the station controlled by synchronizing Equipment GD8 can be converted into the CDB CE data forma
43、ts, and through the papers to copy or synchronize GD84. the operation of digital substationDigital substation system to achieve the full hierarchical distributed application。 first and second device to achieve effective electrical isolation, interoperability between devices。 information integration
44、has increased, reduce the number of automation equipment。 station electrical quantities collected United blocking signal transmission and equipment trip command to run all through the fiber opticnetworks。 has a higher than conventional automation system reliability, availability, security。 substatio
45、n automation system is to ensure that primary and secondary equipment, the normal operation of the core, daily operation and maintenance shouldbe given more attention to the information prompted to run equipmen。tconcerncommunication device alarm interrupt event log information tips。 concerns real-ti
46、me可编辑资料 - - - 欢迎下载精品名师归纳总结monitoring and control console prompt warning information。 network communication interruption should check the device prompt the switch state of communication lines。 case no display device, it should ascertain whether the loss of power outage, such as the reasons for withdr
47、awal should be identified and then put into operation。 after power should conduct a comprehensive inspection to confirm installation of the normal operation after running the program is another advantage ofthe current digital 110kV substation south of change remote operation can be achieved has been
48、 the general order of the control and operation programmed operation program of the operating system is pre-set through the automated process operation of the substation equipment series, issued by the operating instructions is to grant an order by the automated system based on equipment corresponding changes in the amount of remote telemetry to determine the letter of each step is in place, the case confirmation in place the next step, otherwise the alarm.Conclusion110kV substation digital transformation projects to explore the application of the old