《矿用橡套软电缆载流量对照表及速算口诀.doc》由会员分享,可在线阅读,更多相关《矿用橡套软电缆载流量对照表及速算口诀.doc(10页珍藏版)》请在taowenge.com淘文阁网|工程机械CAD图纸|机械工程制图|CAD装配图下载|SolidWorks_CaTia_CAD_UG_PROE_设计图分享下载上搜索。
1、. .矿用橡套软电缆载流量矿用移动橡套软电缆型号Type:MY 额定电压Rating Voltage:380/660V 芯数截面 mm2导体构造 NO./mm绝缘厚度 mm护套厚度 mm电缆外径 参考重量 kg/km导体铜最大直流电阻 (20 ) /km20 载流(20 ) A标称 l mm最大 mm3 4+1 456/0.301.43.520.923.06374.9503556/0.304.9503 6+1 684/0.301.43.522.925.18563.3004684/0.303.3003 10+1 1084/0.401.64.027.830.613041.9106484/0.401
2、.9103 16+1 10126/0.401.64.030.333.315451.2108584/0.401.9103 25+1 16196/0.401.84.536.440.122690.780113126/0.401.2103 35+1 16276/0.401.84.540.544.627860.554138126/0.401.2103 50+1 16396/0.402.05.045.550.135540.386173126/0.401.2103 70+1 25360/0.502.05.051.555.145870.272215196/0.400.780矿用移动屏蔽橡套软电缆型号Type:
3、MYP 额定电压Rating Voltage:380/660V 芯数截面mm2导体构造 NO./mm绝缘厚度 mm护套厚度 mm电缆外径参考重量kg/km导体铜最大直流电阻(20 ) /km20 载流量(20 )A标称 mm最大mm3 4+1 456/0.301.43.522.925.27304.9503556/0.304.9503 6+1 684/0.301.43.524.727.29593.3004684/0.303.3003 10+1 1084/0.401.64.029.732.714271.9106484/0.401.9103 16+1 10126/0.401.64.032.235.4
4、16751.2108584/0.401.9103 25+1 16196/0.401.84.538.341.024190.780113126/0.401.2103 35+1 16276/0.401.84.542.446.629520.554138126/0.401.2103 50+1 16396/0.402.05.047.451.037410.386173126/0.401.2103 70+1 25360/0.502.05.052.457.147900.272215196/0.400.780矿用移动屏蔽橡套软电缆型号Type:MYP 额定电压Rating Voltage:660/1440V 芯数
5、截面mm2导体构造NO./mm绝缘厚度mm护套厚度mm电缆外径参考重量kg/km导体铜最大直流电阻(20 ) /km20 载流量(20 )A标称mm最大mm3 10+1 1084/0.401.84.531.734.916401.9106484/0.401.9103 16+1 10126/0.401.84.534.237.618991.2108584/0.401.9103 25+1 16196/0.402.05.040.344.326480.780113126/0.401.2103 35+1 16276/0.402.05.044.448.832010.554138126/0.401.2103 5
6、0+1 16396/0.402.25.551.554.640130.386173126/0.401.2103 70+1 25360/0.502.25.553.959.350790.272215196/0.400.7803 95+1 25475/0.502.46.062.168.162800.206260196/0.400.780采煤机用屏蔽套软电缆型号Type:MC 额定电压Rating Voltage:380/660V 芯数截面mm2导体构造 NO./mm绝缘厚度 mm护套厚度 mm电缆外径参考重量kg/km导体铜最大直流电阻(20 ) /km20 载流量(20 )A标称l mm最大mm3
7、16+1 4+3 2.5126/0.401.64.531.334.416681.2108556/0.304.95049/0.257.9803 25+1 6+4 2.5196/0.401.85.538.441.023240.78011384/0.303.30049/0.257.9803 35+1 6+4 4276/0.401.85.543.948.332340.55413884/0.303.30056/0.304.9503 50+1 10+7 4396/0.402.05.547.751.040800.38617084/0.401.91056/0.304.950采煤机用橡套软电缆型号Type:MC
8、P 额定电压Rating Voltage:380/660V 芯数截面mm2导体构造NO./mm绝缘厚度mm护套厚度mm电缆外径参考重量kg/km导体铜最大直流电阻(20 ) /km20 载流量(20 )A标称mm最大mm3 16+1 4+3 2.5126/0.401.64.533.236.518831.2108556/0.304.95049/0.257.9803 25+1 6+4 2.5196/0.401.85.540.344.325710.78011384/0.303.30049/0.257.9803 35+1 6+4 4276/0.401.85.545.850.435270.5541388
9、4/0.303.30056/0.304.9503 50+1 10+7 4396/0.402.05.551.555.044000.38617084/0.401.91056/0.304.950采煤机用橡套软电缆型号Type:MCP 额定电压Rating Voltage:660/1140V 芯数截面mm2导体构造NO./mm绝缘厚度mm护套厚度mm电缆外径参考重量kg/km导体铜最大直流电阻(20 ) /km20 载流量(20 )A标mm最大mm3 35+1 6+3 6276/0.402.06.047.251.437580.55413884/0.303.30084/0.303.3003 50+1 1
10、0+3 6396/0.402.27.054.358.648880.38617084/0.301.91084/0.303.3003 70+1 16+3 6360/0.502.27.059.664.357830.272210126/0.401.21084/0.303.3003 95+1 25+3 10475/0.502.47.064.570.174300.206250196/0.400.78084/0.401.910矿用电钻电缆型号Type:MZ 额定电压Rating Voltage:300/500V 芯数截面mm2导体构造NO./mm绝缘厚度mm护套厚度mm电缆外径参考重量kg/km导体铜最大直
11、流电阻(20 ) /km20 载流量t(20 )A标称mm最大mm3 2.5+1 2.577/0.201.03.517.719.44888.8202577/0.208.8203 4+1 4126/0.201.03.519.121.06025.39035126/0.205.3903 2.5+1 2.5+1 2.577/0.201.03.518.920.85218.8202577/0.208.82077/0.208.8203 4+1 4+1 4126/0.201.03.520.522.66485.39035126/0.205.390126/0.205.390矿用电钻电缆型号Type:MZP 额定电
12、压Rating Voltage:300/500V 芯数截面mm2导体构造NO./mm绝缘厚度mm护套厚度mm电缆外径参考重量Cable kg/km导体铜最大直流电阻(20 ) /km20 载流量(20 )A标称mm最大mm3 2.5+1 2.577/0.201.03.519.521.56418.8202577/0.208.8203 4+1 4126/0.201.03.521.023.17665.39035126/0.205.3903 2.5+1 2.5+1 2.577/0.201.03.521.123.27438.8202577/0.208.82077/0.208.8203 4+1 4+1 4126/0.201.03.522.825.19095.39035126/0.205.390126/0.205.390速算口诀:二点五下乘以九,往上减一顺号走。 三十五乘三点五,双双成组减点五。 条件有变加折算,高温九折铜升级。 穿管根数二三四,八七六折满载流. .word.